Operation and Maintenance Manual
495B ML TM (S)
85
Last Updated - 08/31/2016
AIR CLEANERS WITH VACUATOR VALVE
On vacuator valve equipped models, (see figure 3) dust
cup service is cut to a minimum. A quick check to see
that the vacuator valve is not inverted, damaged, or
plugged is all that is necessary.
DUST CUP
VACUATOR VALVE
Figure 3
CHECKING AIR CLEANER RESTRICTION
Check the Air Cleaner Restriction Indicator daily for restriction. Restriction is caused by dust and dirt
accumulating on the Air Cleaner Element. The method used to check the restriction will depend upon the type of Air
Cleaner on the machine.
AIR CLEANERS WITH RESTRICTION INDICATORS
These air cleaners have a restriction indicator mounted to the Air
Cleaner body (see Figure 4). The indicator plunger will be in the
green zone when the Air Cleaner is empty - and will move up towards
the red
zone when the Air Cleaner is full of dust and dirt. When
in the red zone, this means the Air Cleaner
element needs to be
replaced. See Replacing The Air Cleaner Element later on.
Figure 4
AIR CLEANERS WITHOUT RESTRICTION INDICATORS:
Measure the restriction of the Air Cleaner with a service gauge, or a water manometer at the restriction tap provided
in the Air Cleaner, the transfer pipe, or the blower intake. Replace the element only when the restriction has reached
the maximum allowed by the engine manufacturer. Contact the Barko Service Department for maximum values and
any other questions concerning this method.
Check the Air Cleaner Assembly daily for cracks,
loose clamps, or any other damage. If debris is able
to bypass the Air Cleaner for any reason, it can
damage
the
engine.
REPLACING THE AIR CLEANER ELEMENT
For minimum vehicle downtime, replace dirty air cleaner element with a new element. DO NOT TRY TO CLEAN THE
ELEMENT! Do not leave air cleaner open to the environment longer than it takes to remove element, inspect and
clean inside of air cleaner body, and install a new element.
When restriction indicates that element servicing is required, see the replacement steps on the next page.
SAFETY ELEMENT SERVICE (IF APPLICABLE)
The safety element is not intended to be cleaned.
For maximum engine protection and air cleaner service life, replace the safety element with a new safety element
every third primary element change.
RESTRICTION
INDICATOR
AIR CLEANER MAINTENANCE CONTINUED...
Summary of Contents for 495B SD
Page 3: ...Introduction...
Page 7: ......
Page 16: ...Maintenance...
Page 19: ...Operation and Maintenance Manual 495B ML TM S 19 Last Updated 08 31 2016 SERVICE SCHEDULE...
Page 29: ...Hydraulic...
Page 57: ...Electrical...
Page 58: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 58 ELECTRICAL SCHEMATIC...
Page 78: ...Maintenance...
Page 88: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 88 Structural...
Page 95: ...Trouble Shooting...