Operation and Maintenance Manual
Last Updated - 08/31/2016
495B ML TM (S)
62
INSTALLING A NEW BATTERY
1. Remove battery cables. Remember position of positive terminal and negative terminal so you can connect them
again
correctly.
2. Remove battery hold-down bar. Remove battery from compartment.
3. Clean terminal posts of new battery and cable connections with wire brush.
4. Install new battery in compartment. Install hold-down bar.
5. Install and tighten battery cables. Connect negative cable last to prevent sparks.
Do not touch battery terminals with any metal. Sparks may occur,
causing damage to battery and personal injury.
ALTERNATOR DRIVE BELT ADJUSTMENT
1. Loosen alternator adjusting bolt and mounting bolt. See Figure 1.
2. Move alternator along adjustment bar to adjust tension of belt to
have 1/2" movement at 10 pounds of pressure at center of belt.
3. Tighten alternator adjusting bolt and mounting bolt.
After a new drive belt has been installed, it will be necessary to adjust
it after 8 hours of machine operation.
ALTERNATOR MAINTENANCE
CHECKING THE WIRING
1. Turn the starter switch on.
2. Connect a volt meter between the ground and: (See Figure 2.)
a) the No. 1 alternator connector.
b) the No. 2 alternator connector.
c) the "BAT" connector.
ELECTRICAL SYSTEM MAINTENANCE CONTINUED...
Summary of Contents for 495B SD
Page 3: ...Introduction...
Page 7: ......
Page 16: ...Maintenance...
Page 19: ...Operation and Maintenance Manual 495B ML TM S 19 Last Updated 08 31 2016 SERVICE SCHEDULE...
Page 29: ...Hydraulic...
Page 57: ...Electrical...
Page 58: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 58 ELECTRICAL SCHEMATIC...
Page 78: ...Maintenance...
Page 88: ...Operation and Maintenance Manual Last Updated 08 31 2016 495B ML TM S 88 Structural...
Page 95: ...Trouble Shooting...