The
I1
pushed command r=192.168.0.20/c=80 will activate the relay on the control station for the Relay
toggle duration time set in the control station when the RING button is pressed on the door station panel.
The
I1
released command has to be blank.
Adjust the Relay toggle duration according to the specification of the door strike used.
All other commands are not used and can be left blank or as is.
Security settings
These settings need not to be changed for now.
Adjust them later according to your security needs.
8.2.2 Control station configuration
Lets take a look on how to configure the control station.
Wiring
The control station is connected to an intercom panel: Speaker to speaker out (C).
Microphone to Microphone In (E or F).
The TALK button to Input 0 (B1 and B3).
The DOOR button to Input 1 (B2 and B3).
The flash or buzzer to Relay normally open (B4) and Relay common (B5).
Network settings
SonicIP is disabled, no need to hear it on power up as the IP is static and known and will not be power
cycled anyway.