Annuncicom
User Manual Version 4.07
CTS IN (RS-232)
Click the "SET" link to simulate CTS being activated. Click the "CLR" link to simulate CTS being
deactivated. The indicator next to "CTS IN" shows the physical status of the CTS GREY: inactive,
GREEN: active (simulation is not shown!)
- not activated
- activated
RTS OUT (RS-232)
Click the "SET" link to activate RTS. Click the "CLR" link to deactivate RTS. The indicator next to "RTS
OUT" shows the physical status of the RTS:
- not activated
- activated
2.2.5 Supervision
One of the range of Annuncicom HW, the Annunciocm 155, also supports supervision of microphone,
speaker and temperature. On the Annuncicom 155 the following fields are also displayed.
MIC
This field shows the status of the microphone:
- microphone detected and operating properly
- microphone not attached or short-cut detected
SPEAKER
This field is available only on devices supporting supervision. Shows the status of the attached speaker.
The speaker is supervised with an in-band tone. The supervision must be configured in the Audio
section and is by default off. The following values are displayed:
- supervision switched off or no value available yet
- speaker detected and operating properly
- speaker not attached or short-cut detected
TEMP
Shows the device's internal temperature in degrees centigrade. The information is available only on
devices supporting supervision.
BARIX AG
| 28. Jan. 2014 | Controlling the Annuncicom | Page 10/54