Annuncicom
User Manual Version 4.07
Init Sequence
This command sequence is always executed immediately after startup (see further below for commands).
Default:
""
I0 pushed command
Configure which command should be issued when the I0 button is pushed (see further below for commands).
Default:
"c=83"
I0 released command
Configure which command should be issued when the I0 button is released (see further below for
commands).
Default: "c=84".
I1 pushed command
Configure which command should be issued when the I0 button is pushed (see further below for commands).
Default: "r=c=78"
I1 released command
Configure which command should be issued when the I0 button is released (see further below for
commands).
Default:
"r=c=79"
Relay pulse duration
Defines the amount of time (in tenths of a second) the door strike will buzz when the "Dout" pulse command
is received.
Default:
"30" (3 seconds)
CTS close command
Configures which command is issued when the CTS signal on the serial connector is activated (see further
information below in the command description).
Default:
"r=c=78"
CTS open command
Configures which command is issued when the CTS signal on the serial connector is deactivated (see further
information below in the command description).
Default: "r=c=79"
RTS pulse duration
Defines the RTS pulse duration (in tenths of a second) when the "RTS" pulse command is received.
Default: "0".
BARIX AG
| 28. Jan. 2014 | Configuration | Page 21/54
Summary of Contents for Annuncicom