background image

Manual 2100-560
Page

2 of 8

TABLE OF CONTENTS

Programming & Features

Controller Programming & Features .......................... Page 3

Home Screen Features .............................................. Page 3

Temporary Temperature Override ...................... Pages 3 & 4

Indoor Blower Settings ............................................... Page 4

Setting Date/Time ...................................................... Page 4

Scheduling ......................................................... Pages 4 & 5

Alarm Feature ............................................................ Page 5

Security Settings ................................................ Pages 5 & 6

Trend Logs ................................................................. Page 7

Restart ............................................................... Pages 7 & 8

Restore Factory ......................................................... Page 8

Summary of Contents for ECU Series

Page 1: ...Manual 2100 560 Page 1 of 8 ADVANCED PROGRAMMING FEATURES Controller 8403 066 ECU Series Controller Manual 2100 560 Supersedes NEW File Tab 19 Date 05 02 11...

Page 2: ...rogramming Features Page 3 Home Screen Features Page 3 Temporary Temperature Override Pages 3 4 Indoor Blower Settings Page 4 Setting Date Time Page 4 Scheduling Pages 4 5 Alarm Feature Page 5 Securit...

Page 3: ...mperature from the Home Screen will result in a temporary override which will last for a programmable length of time factory default is 1 hour To change temperature temporarily from the Home Screen pr...

Page 4: ...ill operate during call for cooling or heating but will cycle off when no compressor or no heating is needed 5 Enter button to save changes to Fan Modes Selections Repeat steps 4 through 5 for all cha...

Page 5: ...on 8 Enter button to save scheduling programming 9 Repeat steps 3 8 as necessary to complete Scheduling time periods 10 Left button to navigate back to Main Menu Screen 11 Left button to navigate back...

Page 6: ...own button s to select among the three 3 levels of security passwords User Operator and Administrator None Level has no Password 10 Enter button to select specific Password 11 Up Down and Right button...

Page 7: ...rammable 7 Enter button to select chosen Log and enter Setup Screen 8 Down button to highlight Object Ref 9 Select button to select Object Ref and choose from the following AI1 Space Temperature Facto...

Page 8: ...select enter Advanced Screen 4 Down button through entries to highlight Restart Restore 5 Select button to select enter Restart Restore Screen 6 Controller will ask for Admin Level Password Factory De...