8. Cabling of the X8 display
8.1
Power cabling of the X8 display
Power boxes
Barco provides several types of power boxes. Depending on the size of the X8 rental display you can choose to use the mono phase
power box, custom made power box or rental power box. The type of power box, does not in
fl
uence the power cabling of the X8
rental display. See installation manual of the concerned power box for installation instructions.
W
ARNING
:
Risk of electric shock / Risk of
fi
re:
To protect against risk of
fi
re caused by overloading of power cables, MAXIMUM 4 X8 Connection Boxes may
be connected in parallel. Each power source cable supplying maximum 4 X8 Connection Boxes should be
protected by a circuit breaker or fuses rated 16 A / 250 VAC (15 A / 250 VAC in the USA and Canada). Note that
one X8 Connection Box requires 200-240 VAC, 50-60 Hz, 3.6 amps at 200 VAC.
Necessary parts
•
Power box(es) with matching cables.
•
Power linking cables.
•
Dummy power plugs
How to realize the power cabling of the X8 display?
1. Install the power box nearby the X8 display. Ensure the power box provides as much power circuits as required to energize the
display in a safe manner. If necessary, install several power boxes. See manual of the used power box for installation instructions.
2. Connect a power source cable coming from the power box with the lower tile in a column of 4 X8 Connection Boxes high.
Note:
Depending on the type of used power box, a multi power cable in combination with a spider connector is inserted between
the power box and the power source cable leading to the X8 tile. See manual of the used power box to realize the cabling
between power box and X8 display.
3. Create a power branch of maximum 4 X8 Connection Boxes by placing a power linking cable between the X8 Connection Box of
the tiles above. Note that the lowest X8 Connection Box is receiving power directly from the power box via a power source cable.
4. Place a dummy power plug on the power output socket of the upper X8 Connection Box in the power branch.
5. Repeat from step 2 until all X8 Connection Boxes are provided with power.
Example of power cabling
The example below shows the power cabling of a four by eight X8 display. The power box (1) is connected via a multi power cable
(2) with a spider connector (3). Each spider output cable leads to a column of 4 X8 Connection Boxes. The power connection in this
column is realized with a power linking cable (4). Note that the unused power output socket is sealed with a dummy power plug (5).
54
R5905160 X8 RENTAL DISPLAY 25/02/2013
Summary of Contents for X8
Page 1: ...X8 Rental Display Installation manual R5905160 03 25 02 2013 ...
Page 14: ...1 Safety 10 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 42: ...6 Setup process of a X8 rental display 38 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 56: ...7 Basic setup procedures 52 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 62: ...8 Cabling of the X8 display 58 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 82: ...A Dimensions 78 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 86: ...B Specifications 82 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...
Page 94: ...D Product Green Compliance 90 R5905160 X8 RENTAL DISPLAY 25 02 2013 ...