165
R5906112 /15
UDX
Image 11–17 Example of the laser bank group menu
6.
If you want notifications to be disabled for a specific group of laser banks, disable the
Enable notifications
for this group
slider.
11.6 Advanced settings – Tilt sensor calibration
CAUTION:
The calibration procedure resets the values of the tilt sensor to 0 in the current position
of the projector. For the optimal working of the tilt sensor it is important to make sure the projector is
perfectly level when performing this procedure. If not, the tilt sensor will not function as desired once
the calibration has been completed.
Required tools
Level
How to calibrate the tilt sensor?
1.
Place the projector on a flat surface and make sure it is positioned level in all directions. Use a level tool to
help ensure this.
2.
In the main menu, navigate to
Settings
→
Maintenance
→
Advanced
, while you are logged in.
Image 11–18 Maintenance menu, Advanced
3.
Enter the service code.
4.
In the
Service
menu, select
Tilt sensor calibration
.
Image 11–19 Advanced menu, Tilt sensor calibration
5.
Confirm your action.
Summary of Contents for UDX
Page 1: ...ENABLING BRIGHT OUTCOMES User manual UDX...
Page 22: ...R5906112 15 UDX 22 Safety information...
Page 30: ...R5906112 15 UDX 30 Getting started...
Page 158: ...R5906112 15 UDX 158 GUI System Settings...
Page 170: ...R5906112 15 UDX 170 GUI Status menu...
Page 198: ...R5906112 15 UDX 198 Specifications...
Page 208: ...R5906112 15 UDX 208 Video timing tables...
Page 214: ...R5906112 15 UDX 214 DMX chart...
Page 224: ...R5906112 15 UDX 224 WiFi GSM compliance information...
Page 228: ...R5906112 15 UDX 228 List of tools...
Page 234: ...R5906112 15 UDX 234 Index...
Page 235: ......