Barco – TransForm A – DOC-3358-2 – service manual – Revision 06 – March 2007
_________________________________________________________________________
4-13
The results for I1, I2 and M1 are each smaller than the maximum allowed values; the configuration is possible.
Calculation templates
To calculate the ability to insert additional cards into your system, below you find a blank template of a calcula-
tion table for the O
MNI
B
US
A12
AGS-3359-0
and the O
MNI
B
US
A18
AGS-3335-0/-1
.
Calculation template for an O
MNI
B
US
A12 AGS-3359-0:
I1 (3,3 V)
I2 (5 V)
M1
Value
Amount Result
Value
Amount
Result
Value
Amount
Result
System base load
0.9 * 1 = 0.9 0.20
* 1
= 0.2
326 * 1
= 326
+ UGX
G
RAPHIC
C
ARD
1.6 *
=
2.50
*
=
324 *
=
+ O
MNI
S
CALER
UXGA
1.4 *
=
3.00
*
=
32 *
=
+ Q
UAD
A
NALOG
V
IDEO
C
ARD
2.5 *
=
0.80
*
=
66 *
=
+ D
UAL
DVI
I
NPUT
C
ARD
3.5 *
=
2.80
*
=
66 *
=
+ D
UAL
RGB
I
NPUT
C
ARD
1.6 *
=
1.50
*
=
66 *
=
+ S
TREAMING
V
IDEO
C
ARD
3.4 *
=
2.20
*
=
66 *
=
+ Q
UAD
SDI
V
IDEO
C
ARD
1.8 *
=
1.90
*
=
66 *
=
+ optical cables
–
0.36
*
=
–
=
Maximum allowed
45.0
50.0
4096
Table 4-10
Calculation template for O
MNI
B
US
A12 AGS-3359-0
Calculation template for an O
MNI
B
US
A18 AGS-3335-0/-1:
I1 (3,3 V)
I2 (5 V)
M1
Value
Amount Result
Value
Amount
Result
Value
Amount
Result
System base load
7.4 * 1 = 7.4 0.90
* 1
= 0.9
326 * 1
= 326
+ UGX
G
RAPHIC
C
ARD
1.6 *
=
2.50
*
=
324 *
=
+ O
MNI
S
CALER
UXGA
1.4 *
=
3.00
*
=
32 *
=
+ Q
UAD
A
NALOG
V
IDEO
C
ARD
2.5 *
=
0.80
*
=
66 *
=
+ D
UAL
DVI
I
NPUT
C
ARD
3.5 *
=
2.80
*
=
66 *
=
+ D
UAL
RGB
I
NPUT
C
ARD
1.6 *
=
1.50
*
=
66 *
=
+ S
TREAMING
V
IDEO
C
ARD
3.4 *
=
2.20
*
=
66 *
=
+ Q
UAD
SDI
V
IDEO
C
ARD
1.8 *
=
1.90
*
=
66 *
=
+ optical cables
–
0.36
*
=
–
=
Maximum allowed
70.0
50.0
4096
Table 4-11
Calculation template for O
MNI
B
US
A18 AGS-3335-0/-1