Restriction Zone (RZ) based on the HD

The HD depends on the amount of lumens produced by the projector and the type of lens installed. See chapter

HD in function of

modifying optics

page 11.

To protect untrained end users (as cinema visitors, spectators) the installation shall comply with the following installation requirements:
Operators shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators' eyes
from being in the hazard distance. Radiation levels in excess of the limits will not be permitted at any point less than 2.0 meter (SH) above
any surface upon which persons other than operators, performers, or employees are permitted to stand or less than 1.0 meter (SW)
lateral separation from any place where such persons are permitted to be. In environments where unrestrained behavior is reasonably
foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an
individual sitting on another individual's shoulders, within the HD.

These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section 6.6.3.5.

The installer and user must understand the risk and apply protective measures based upon the hazard distance as indicated on the label
and in the user information. Installation method, separation height, barriers, detection system or other applicable control measure shall
prevent hazardous eye access to the radiation within the hazard distance.

For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present should
be positioned in accordance with

the fixed projector installation

parameters, resulting in a HD that does not extend into the audience

area unless the beam is at least 2.0 meter above the floor level. In environments where unrestrained behavior is reasonably foreseeable,
the minimum separation height should be greater than or equal to 3.0 meter to prevent potential exposure, for example by an individual
sitting on another individual's shoulders, within the HD. Sufficiently large separation height may be achieved by mounting the image
projector on the ceiling or through the use of physical barriers.

RA

TH

PR

RZ

HD

SW

1

m

SW

SW

SW

HD

EXIT

SH

RA

PR

TH

RZ

SH

(B) TOP VIEW

(A) SIDE VIEW

Image 1-1

A

Side view.

B

Top view.

RA

Restricted Access location (boot area of projector).

PR

Projector.

TH

Theater.

RZ

Restriction Zone in the theater.

SH

Separation Height.

SW

Separation Width.

Based on national requirements, no person is allowed to enter the projected beam within the zone between the projection lens and the
related hazard distance (HD). This shall be physically impossible by creating sufficient separation height or by placing barriers. The
minimum separation height takes into account the surface upon which persons other than operator, performers or employees are
permitted to stand.

On Image 1-2 a typical setup is displayed. It must be verified if these minimum requirements are met. If required a restricted zone (RZ) in
the theater must be established. This can be done by using physical barrier, like a red rope as illustrated in Image 1-2.

The restricted area sticker can be replaced by a sticker with only the symbol.

Safety

Summary of Contents for SP4K-12C

Page 1: ...ENABLING BRIGHT OUTCOMES Safety Manual SP4K C ...

Page 2: ...istered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ... normal operation fails Notice on optical radiation This projector embeds extremely high brightness radiance lasers this laser light is processed through the projector s optical path Native laser light is not accessible by the end user in any use case The light exiting the projection lens has been diffused within the optical path representing a larger source and lower radiance value than native la...

Page 4: ...reaker of a current rating less than 40A the cross sectional area of the conductors in the power supply cord must comply with the local electrical code regulations where the projector is installed The cable gland of the power supply cord has a clamping range between 11 mm and 21 mm cable diameter of the power supply cord must be in this range 11 21 mm Disconnect the power to the projector mains te...

Page 5: ... projector to rain or moisture In the event of fire use sand CO2 or dry powder fire extinguishers Never use water on an electrical fire Always have service performed on this projector by authorized Barco service personnel Always insist on genuine Barco replacement parts Never use non Barco replacement parts as they may degrade the safety of this projector Slots and openings in this equipment are p...

Page 6: ...n replacement parts are required be sure the service technician has used original Barco replacement parts or authorized replacement parts which have the same characteristics as the Barco original part Unauthorized substitutions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitutions may void warranty Safety check Upon completion of any ser...

Page 7: ...power from the unit See ID label for ratings WARNING HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY Déconnecter l alimentation des bornes du réseau et déconnecter le câble de la prise UPS pour la coupure de toute l alimentation de l appareil Voir l étiquette d identification pour les paramètres ATTENTION COURAN...

Page 8: ...example projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present should be positioned in accordance with the fixed projector installation parameters resulting in a HD that does not extend into the audience area unless the beam is at least 2 0 meter above the floor level In environments where unrestrained behavior is reasonably foreseeable the...

Page 9: ... times Effects other than front or rear screen projections shall not be performed Communication shall be maintained with other personnel assisting in surveillance of the LIP projection In the event of any unsafe condition immediately terminates or designate the termination of LIP projection light Install one or more readily accessible controls to immediately terminate LIP projection light The powe...

Page 10: ...t is mandatory to create a restricted zone within the beam areas closer than any HD In the enclosed projection area the combination of two restricted zones are relevant The restricted zone of the projected beam toward the screen taking into account 1 meter Separation Width SW from the beam onward Combined with the restricted zone related to the rear reflection from the screen HDreflection also tak...

Page 11: ...ard Distance 0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 11 5 12 Hazard Distance HD m Throw Ra o TR SP4K 25C SP4K 20C SP4K 15C SP4K 12C 1 2 3 4 1 1 2 2 3 4 4 Image 1 4 HD Hazard Distance TR Throw Ratio Safety ...

Page 12: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5910027 02 2019 04 30 ...