R5910027 /02

SP4K-C

7

Label image

Label description

Label location

警告!勿观看光束 眼睛勿直接接触可允许暴露的光束

RG3 IEC EN 62471-5:2015 CLASS 1 IEC

EN 60825-1:2014

危害距离:请参考安全手册

瞥告!结勿注祝光源. 禁止眼睛曝露在光源照射鱿坦。雷射危险等级

RG3 IEC EN 62471-5:2015

CLASS 1 IEC EN 60825-1:2014

安全危害距黔:清冬考安全手册.

Hazard RG3: optical radiation warning symbol

Hazard RG3: not for household use symbol

Electric related safety labels

Label image

Label description

Label location

Déconnecter l’alimentation des bornes du réseau et déconnecter le câble de la prise UPS

pour la coupure de toute l’alimentation de l’appareil.

ATTENTION : 

COURANT DE FUITE ÉLEVÉ RACCORDEMENT À LA TERRE INDISPENSABLE AVANT

LE RACCORDEMENT AU RÉSEAU

VOIR LA NOTICE D’INSTALLATION AVANT DE RACCORDER AU RÉSEAU

Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for

removal of all power from the unit.

WARNING : 

HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY

SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY

DELTA CONFIGURATION

L1

W2

U1

U2

V1

V2

W1

L2

L3

PE

3W+PE

Δ

MONO PHASE

MONO PHASE

L1

W2

U1

U2

V1

V2

W1

PE

L1+N+PE 

N

STAR CONFIGURATION

L1

W2

U1

U2

V1

V2

W1

L2

L3

PE

N

3W+N+PE 

Y

3.5 Nm

0.75 Nm

3.3 Nm

TORQUE VALUE

WITH UPS

L1

UPS

L2

UPS

PE

UPS

WITHOUT UPS

(NOT CONNECTED)

Disconnect the power to the unit mains terminals and unplug
power cord at UPS inlet for removal of all power from the
unit. See ID-label for ratings.

WARNING

: HIGH LEAKAGE

CURRENT EARTH CONNECTION ESSENTIAL BEFORE
CONNECTING SUPPLY.

SEE INSTALLATION

INSTRUCTIONS BEFORE CONNECTING TO THE
SUPPLY

.

Déconnecter l

alimentation des bornes du réseau et

déconnecter le câble de la prise UPS pour la coupure de
toute l

alimentation de l

appareil. Voir l

étiquette

d

identification pour les paramètres.

ATTENTION

:

COURANT DE FUITE ÉLEVÉ RACCORDEMENT À LA
TERRE INDISPENSABLE AVANT LE RACCORDEMENT
AU RÉSEAU.

VOIR LA NOTICE D

INSTALLATION AVANT

DE RACCORDER AU RÉSEAU

.

断开放映机主电源端的电源并从

UPS

电源接入插座上拔下电

源线, 切断放映机的所有电源。警告: 大漏,电流在接通电
源之前必须先接地

.

在与电源连接前请查看安装说明书

.

Printed on Mains cover

CAUTION

! DOUBLE POLE / NEUTRAL FUSING HIGH RESIDUAL VOLTAGE

Wait min 8

minutes before removal of the switch power supply.

WARNING: RISK OF ELECTRIC SHOCK

!

SWITCH OFF AND UNPLUG BEFORE REMOVING THIS COVER!

警告 雙極

/

中性熔斷 高殘餘電壓 等待至少

8

分鐘

,

才可以移除電源開關 危險

:

電擊風險 移開蓋子之

前,請關閉並拔下電源插頭

ATTENTION!

DOUBLE PÔLE / FUSIBLE SUR LE NEUTRE HAUTE TENSION RÉSIDUELLE -

Attendre min 8 minutes avant le déplacement de l

alimentation à découpage

ATTENTION :

RISQUE DE CHOCS ÉLECTRIQUES!

ÉTEINDRE ET DÉCONNECTER AVANT OUVERTURE

DU COUVERCLE

Printed on SMPS cover

1.4 High Brightness precautions: Hazard Distance (HD)

HD

Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface unit
becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to be) unsafe
for exposure if the distance from a person to the light source is less than the HD.

Safety

Summary of Contents for SP4K-12C

Page 1: ...ENABLING BRIGHT OUTCOMES Safety Manual SP4K C ...

Page 2: ...istered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ... normal operation fails Notice on optical radiation This projector embeds extremely high brightness radiance lasers this laser light is processed through the projector s optical path Native laser light is not accessible by the end user in any use case The light exiting the projection lens has been diffused within the optical path representing a larger source and lower radiance value than native la...

Page 4: ...reaker of a current rating less than 40A the cross sectional area of the conductors in the power supply cord must comply with the local electrical code regulations where the projector is installed The cable gland of the power supply cord has a clamping range between 11 mm and 21 mm cable diameter of the power supply cord must be in this range 11 21 mm Disconnect the power to the projector mains te...

Page 5: ... projector to rain or moisture In the event of fire use sand CO2 or dry powder fire extinguishers Never use water on an electrical fire Always have service performed on this projector by authorized Barco service personnel Always insist on genuine Barco replacement parts Never use non Barco replacement parts as they may degrade the safety of this projector Slots and openings in this equipment are p...

Page 6: ...n replacement parts are required be sure the service technician has used original Barco replacement parts or authorized replacement parts which have the same characteristics as the Barco original part Unauthorized substitutions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitutions may void warranty Safety check Upon completion of any ser...

Page 7: ...power from the unit See ID label for ratings WARNING HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY Déconnecter l alimentation des bornes du réseau et déconnecter le câble de la prise UPS pour la coupure de toute l alimentation de l appareil Voir l étiquette d identification pour les paramètres ATTENTION COURAN...

Page 8: ...example projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present should be positioned in accordance with the fixed projector installation parameters resulting in a HD that does not extend into the audience area unless the beam is at least 2 0 meter above the floor level In environments where unrestrained behavior is reasonably foreseeable the...

Page 9: ... times Effects other than front or rear screen projections shall not be performed Communication shall be maintained with other personnel assisting in surveillance of the LIP projection In the event of any unsafe condition immediately terminates or designate the termination of LIP projection light Install one or more readily accessible controls to immediately terminate LIP projection light The powe...

Page 10: ...t is mandatory to create a restricted zone within the beam areas closer than any HD In the enclosed projection area the combination of two restricted zones are relevant The restricted zone of the projected beam toward the screen taking into account 1 meter Separation Width SW from the beam onward Combined with the restricted zone related to the rear reflection from the screen HDreflection also tak...

Page 11: ...ard Distance 0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 11 5 12 Hazard Distance HD m Throw Ra o TR SP4K 25C SP4K 20C SP4K 15C SP4K 12C 1 2 3 4 1 1 2 2 3 4 4 Image 1 4 HD Hazard Distance TR Throw Ratio Safety ...

Page 12: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5910027 02 2019 04 30 ...