background image

R5910027 /02

SP4K-C

9

P
R

RESTRICTED

AREA

R
E

S

T

R
I

C
T

E

D

A
R
E

A

Image 1-2

USA market

For LIPs (Laser Illuminated Projectors) installed in the USA market other restriction zone conditions apply.

LIPs for installation in restrained environment (cinema theaters) shall be installed at height vertically above the floor such that the bottom
plane of the hazard distance zone shall be no lower than 2.5 meters above the floor. Horizontal clearance to the hazard distance zone
shall be not less than 1 meter.

LIPs for installations in unrestrained environment (large venues,..) shall be installed at a height vertically above the floor such that the
bottom plane of the Hazard distance Zone shall be no lower than 3 meters above the floor. Horizontal clearance to the hazard distance
zone shall be not less than 2.5 meters. Any human access horizontally to the Hazard Zone, if applicable, shall be restricted by barriers. If
human access is possible in an unsupervised environment, the horizontal or vertical clearances shall be increased to prevent exposure to
the hazard distance zone.

In addition for temporary installations (e.g.: rental and staging, lease, events

) the following requirements apply:

This product can only be installed by Barco or sold or leased only to valid laser light show variance holders. In other words our
installers are required to have an approved laser light show variance. Such installers may currently hold a valid variance for production
of Class IIIb and IV laser light shows and/or for incorporation of the RG3 LIPs into their shows. Dealers and distributors are also
required to obtain a valid laser light show variance.

This product shall be located in such a way that all propagating beam paths within the Restriction Zone, and the audience can be
directly observed at all times.

Effects other than front or rear screen projections shall not be performed.

Communication shall be maintained with other personnel assisting in surveillance of the LIP projection.

In the event of any unsafe condition, immediately terminates (or designate the termination) of LIP projection light.

Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at the projector side is
considered as a reliable disconnect device. When required to switch off the projector, disconnect the power cord at the projector side. In
case the power input at the projector side is not accessible (e.g. truss mount), the socket outlet supplying the projector shall be installed
nearby the projector and be easily accessible, or a readily accessible general disconnect device shall be incorporated in the fixed wiring.

Laser light shows can be requested via the FDA online eSubmitter portal or via FDA Form FDA Form 3147 referencing to Barco

s

variance approval 2018-V-2875.

The installation checklist for laser illuminated RG3 projectors must be fully completed after the installation and sent to [email protected].
This checklist can be downloaded from the Barco website. Only when the installer is a valid laser light show variance holder the checklist
should not be sent to Barco.

1.5 HD for fully enclosed projection systems

HD

Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface unit
becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to be) unsafe
for exposure if the distance from a person to the light source is less than the HD.

Restriction Zone (RZ) based on the HD

The projector is also suitable for rear projection applications; projecting a beam onto a defuse coated projection screen. As displayed in
Image 1-3 two areas should be considered: the restricted enclosed projection area (RA) and the observation area (TH).

Safety

Summary of Contents for SP4K-12C

Page 1: ...ENABLING BRIGHT OUTCOMES Safety Manual SP4K C ...

Page 2: ...istered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ... normal operation fails Notice on optical radiation This projector embeds extremely high brightness radiance lasers this laser light is processed through the projector s optical path Native laser light is not accessible by the end user in any use case The light exiting the projection lens has been diffused within the optical path representing a larger source and lower radiance value than native la...

Page 4: ...reaker of a current rating less than 40A the cross sectional area of the conductors in the power supply cord must comply with the local electrical code regulations where the projector is installed The cable gland of the power supply cord has a clamping range between 11 mm and 21 mm cable diameter of the power supply cord must be in this range 11 21 mm Disconnect the power to the projector mains te...

Page 5: ... projector to rain or moisture In the event of fire use sand CO2 or dry powder fire extinguishers Never use water on an electrical fire Always have service performed on this projector by authorized Barco service personnel Always insist on genuine Barco replacement parts Never use non Barco replacement parts as they may degrade the safety of this projector Slots and openings in this equipment are p...

Page 6: ...n replacement parts are required be sure the service technician has used original Barco replacement parts or authorized replacement parts which have the same characteristics as the Barco original part Unauthorized substitutions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitutions may void warranty Safety check Upon completion of any ser...

Page 7: ...power from the unit See ID label for ratings WARNING HIGH LEAKAGE CURRENT EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY Déconnecter l alimentation des bornes du réseau et déconnecter le câble de la prise UPS pour la coupure de toute l alimentation de l appareil Voir l étiquette d identification pour les paramètres ATTENTION COURAN...

Page 8: ...example projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present should be positioned in accordance with the fixed projector installation parameters resulting in a HD that does not extend into the audience area unless the beam is at least 2 0 meter above the floor level In environments where unrestrained behavior is reasonably foreseeable the...

Page 9: ... times Effects other than front or rear screen projections shall not be performed Communication shall be maintained with other personnel assisting in surveillance of the LIP projection In the event of any unsafe condition immediately terminates or designate the termination of LIP projection light Install one or more readily accessible controls to immediately terminate LIP projection light The powe...

Page 10: ...t is mandatory to create a restricted zone within the beam areas closer than any HD In the enclosed projection area the combination of two restricted zones are relevant The restricted zone of the projected beam toward the screen taking into account 1 meter Separation Width SW from the beam onward Combined with the restricted zone related to the rear reflection from the screen HDreflection also tak...

Page 11: ...ard Distance 0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 11 5 12 Hazard Distance HD m Throw Ra o TR SP4K 25C SP4K 20C SP4K 15C SP4K 12C 1 2 3 4 1 1 2 2 3 4 4 Image 1 4 HD Hazard Distance TR Throw Ratio Safety ...

Page 12: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5910027 02 2019 04 30 ...