77
R5913197 /02 SP2K-S
7.3 What are the possible HDD swaps
General
There are several possible scenarios for replacing (exchange) hard drives on the ICMP-X. The situation is
different depending on the device type (ICMP or ICMP-X) and whether to replace one or more disks.
Continuity of data present on the disks is also impacted depending on the type of exchange. Degraded
operation or RAID initialization may be required.
List of available actions
The following table exposes all possible swaps available concerning HDDs on ICMP-X:
Replacing drives should always be done while the power is off.
Type of HDD swap
On ICMP
On ICMP-X
1 HDD replaced.
•
Content is preserved.
•
ICMP automatically starts rebuild.
•
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
•
Content is preserved.
•
ICMP-X automatically starts
rebuild.
•
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
3 HDDs replaced separately
(previous kit of one disk used
three times).
•
All content will be lost.
•
RAID initialization need to be
perform with Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
•
All content will be lost.
•
RAID initialization need to be
perform with Web Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
Barco HDD replacement kit
without S4 ready sticker
(Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN1
storage controller).
On an ICMP with GEN1 storage
Controller:
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately.
On an ICMP with GEN2 storage
Controller:
•
Only usable after RAID
initiali restart.
•
Content can be ingested
immediately after restart.
•
RAID initialization needs to be
perform with Web Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
Barco HDD replacement kit
with S4 ready sticker
(New
Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN2
storage controller).
On an ICMP with GEN1 storage
Controller:
•
Only usable after RAID
initialization with Commun
restart (content can then be
ingested immediately).
On an ICMP with GEN2 storage
Controller:
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately after restart.
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately.
Summary of Contents for SP2K-S
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual SP2K S...
Page 4: ......
Page 8: ...R5913197 02 SP2K S 8...
Page 22: ...R5913197 02 SP2K S 22 Safety...
Page 64: ...R5913197 02 SP2K S 64 Lenses Lens holder...
Page 72: ...R5913197 02 SP2K S 72 ICMP X...
Page 92: ...R5913197 02 SP2K S 92 ICMP X...
Page 100: ...R5913197 02 SP2K S 100 Projector Power Cycle...
Page 106: ...R5913197 02 SP2K S 106 Connectivity...
Page 112: ...R5913197 02 SP2K S 112 1 Image 10 7 Sealed cover fixation Convergence...
Page 120: ...R5913197 02 SP2K S 120 Convergence...
Page 130: ...R5913197 02 SP2K S 130 3 Lift up the cover and remove it reference 2 Projector covers...
Page 144: ...R5913197 02 SP2K S 144 Projector covers...
Page 152: ...R5913197 02 SP2K S 152 List of tools...
Page 156: ...R5913197 02 SP2K S 156 Index...
Page 157: ......