8. Troubleshooting
8. TROUBLESHOOTING
8.1 No image on the Solaris LD display
Check list:
Situation
Solution
Solaris LD display is not
energized.
1.
Check if the power source is energized.
2.
Check if all circuit breakers of the power box are switched on.
3.
Check the power distribution network of the Solaris LD display.
Solaris D2 digitizer is not
energized.
1.
Check if the digitizer is connected with one of the power branches of the Solaris LD
tiles.
2.
Check if the main switch at the rear of the digitizer is switched on.
Wrong Solaris D2 digitizer settings
in the Solaris LD configuration
software XLite toolset.
1.
Ensure the “Output selection” of the digitizer is set to : “
Barco LED Wall
”.
2.
Ensure that “Start system LED-wall” is set to : “
ON
”.
Wrong timings set for the
Solaris D2 digitizer in the
Solaris LD configuration software
XLite toolset.
See user guide of the Solaris LD configuration software (XLite toolset) to determine the
correct timings or use the wizard in the XLite toolset program.
A video signal with black content
is applied to the selected input
slot of the Solaris D2 digitizer.
Apply another video signal to the selected input slot or select another input slot that
doesn’t contain black content.
LED-wall receives no data signal
from the Solaris D2 digitizer.
Check all data connections between local PC, digitizer and LED-wall.
Malfunction resync-unit of the first
tile in the LED-wall.
Replace the resync-unit of the first tile in the LED-wall.
Malfunction Solaris D2 digitizer.
Replace the Solaris D2 digitizer.
8.2 No image on part of Solaris LD display
Check list:
Situation
Solution
Horizontal banner without content
over the full width of the Solaris LD
display.
1.
Check if all circuit breakers of the power box are switched on.
2.
Check the power connection between the power box and the first tile in the power
branch of this inactive banner of tiles.
Horizontal banner without content
over a part of the width of the
Solaris LD display.
Check if the power split cables between the last active and the first inactive tile are well
connected with each other.
R5976773 SOLARIS LD DISPLAY 02/12/2004
63
Summary of Contents for Solaris LD 120-8
Page 1: ...Solaris LD display Installation service manual R5976773 00 02 12 2004 ...
Page 4: ......
Page 26: ...4 Set up process of a Solaris LD display 22 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 66: ...7 Maintenance 1 2 Image 7 1 Remove dust filter 62 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 84: ...A Specifications 80 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 86: ...B Order info 82 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...