2. Installation requirements
2. INSTALLATION REQUIREMENTS
2.1 Installation requirements for the Solaris LD display
Size
The Solaris LD display is delivered in several packages containing separate parts. Each individual part can pass through a standard
door opening to gain easy access to the installation area. It’s obvious that the dimensions of the destination area must cover the
physical dimensions of the Solaris LD display. See specification of the chosen Solaris LD model for exact dimensions.
Weight
The weight of one separated part, without packaging, of the Solaris LD display does not exceed 50 kg. This limitation allows that
the set up of the Solaris LD display can be done by two persons. But, do not underestimate the weight of a complete Solaris LD
display. Be sure that the surface (floor, wall or ceiling) on which the display has to be installed is capable of handling five (5) times
the complete load of the Solaris LD display. See specification of the chosen Solaris LD model to know the complete weight of the
display.
Humidity
The Solaris LD display is designed for indoor use. The humidity level at the operating area must be between 35 and 85%. To forsake
this requirement will result in damage of internal parts of the Solaris LD display.
Ventilation
A lot of energy is transferred into heat. The installation should be such that the amount of air flow required for safe operation of the
equipment is not compromised. Proper ventilation must be provided. The location of the air in- and outlet for the fans will be different
depending on the kind of installation (floor, wall or ceiling). The Solaris LD display must be installed in such a manner that the air in-
and outlets are completely free.
Power
A mono phase power net must be provided at the installation place for the Solaris LD display. The allowed range of the power
voltage is from 190 to 230 volt. Use one power source cable with a section of 10 mm
2
protected with a 63 ampere switch fuse.
Data path
The data path between the Solaris D2 digitizer and the Solaris LD display may not exceed five (5) meter.
Accessibility
It’s not recommended to install the Solaris LD display on a location where the audience are able to touch the display. On the other
hand the installation location must easy be accessible for maintenance purposes like cleaning the air filters.
R5976773 SOLARIS LD DISPLAY 02/12/2004
7
Summary of Contents for Solaris LD 120-8
Page 1: ...Solaris LD display Installation service manual R5976773 00 02 12 2004 ...
Page 4: ......
Page 26: ...4 Set up process of a Solaris LD display 22 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 66: ...7 Maintenance 1 2 Image 7 1 Remove dust filter 62 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 84: ...A Specifications 80 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...
Page 86: ...B Order info 82 R5976773 SOLARIS LD DISPLAY 02 12 2004 ...