9. Service Mode
Proj 1
Proj 2
Proj 3
Proj 4
in
in
in
in
out
out
out
RS
RS
RS
Terminator
Image 9-7
Which information is available
serial number
unique serial number of the lamp
type
lamp type
run time
total time the lamp is used in this or other projectors.
remaining run time
time left before the lamp must be replaced Using the lamp longer than the maximum run time may
damage the projector.
number of strikes
Total times the lamp is started up.
Z-AXIS
indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter
Installation Guidelines).
How to display the lamp menu
1. Push the cursor key
↑
or
↓
to highlight
Lamp
. (menu 9-26)
2. Press
ENTER
to select.
The lamp menu will be displayed. (menu 9-27)
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
DIMMING
MORE...
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 9-26
LAMP
Constant Light output [OFF]
Mode [NORMAL]
Serial number :
R101111
Article number :
R9840xxx
Run time :
10 hours
Remaining run time :
490
hours
Number of strikes :
10
Z_AXIS : 100
Select with
↑
or
↓
then <ENTER>
<EXIT> to return.
Menu 9-27
How to switch the constant light output?
1. Push the cursor key
↑
or
↓
to highlight
Constant Light Output
2. Press
ENTER
to toggle between [OFF], [SLAVE] and [MASTER].
[OFF]
fixed power, no power adaptation.
[SLAVE]
follows the master projector to adjust the CLO. When stand alone and the light output should be adjusted,
put on slave.
[MAS-
TER]
master projector to control the CLO in a chain of projectors.
Mode switching
1. Push the cursor key
↑
or
↓
to highlight
Mode
2. Press
ENTER
to toggle between [NORMAL] and [ECONOMIC].
normal
normal light output
eco-
nomic
reduced light output
R5976654 SLM R12+ 09022004
101
Summary of Contents for SLM R12+ Performer
Page 1: ...EVENTS SLM R12 R9010170 OWNER S MANUAL 09022004 R5976654 00...
Page 4: ......
Page 8: ...Table of contents 4 R5976654 SLM R12 09022004...
Page 38: ...4 Connections 34 R5976654 SLM R12 09022004...
Page 82: ...7 Random Access Adjustment Mode 78 R5976654 SLM R12 09022004...
Page 94: ...8 Installation Mode 90 R5976654 SLM R12 09022004...
Page 112: ...9 Service Mode 108 R5976654 SLM R12 09022004...
Page 114: ...10 Programmable Function Keys 110 R5976654 SLM R12 09022004...
Page 118: ...A Standard Source set up Files 114 R5976654 SLM R12 09022004...