C. Troubleshooting
C. TROUBLESHOOTING
C.1 Error codes
Overview
The following table gives an overview of some important error codes displayed on the LED display of the projector.
Error code
Description
Caused by
Action
2002
lamp start failed
•
hot restrike
•
lamp with many strikes
•
maximum run time exceeded
•
Let cool down the lamp for at
least 3 minutes.
•
Replace the lamp with a new
one
6000
tilt switch
tilt angle is out of specifications
•
Correct projection installation.
•
Change the tilting so that the
tilt angle becomes within the
specifications..
5002
ambient overtemperature
ambient temperature sensed by
the projector is above 45°C
Cool down the installation
environment.
1100
Lamp overtemperature
lamp to hot
Let cool down the lamp
3004
Top fan error
fan is not turning
failure
Call a qualified service engineer
3005
Anode fan error
fan is not turning
failure
Call a qualified service engineer
3006
Cathode fan error
fan is not turning
failure
Call a qualified service engineer
2000
No LPS detected
no communication with lamp power
supply
Call a qualified service engineer
2506
Lamp ignition failed
•
hot restrike
•
lamp with many strikes
•
maximum run time exceeded
•
Let cool down the lamp for at
least 3 minutes.
•
Replace the lamp with a new
one
If problem persists, call a qualified
service engineer
5001
DMD temperature
•
temperature of one or more
DMD’s is too high
•
temperature of one or more
DMD’s is too low
Let cool down the projector. If it
persists, call a qualified service
engineer
1102
Lamp insertion not OK
•
Lamp not fully inserted
•
Screws not fully tightened
•
Check the lamp insertion
•
Tighten the screws
4004
SMPS EEPROM corrupt
•
no EEPROM on SMPS
•
Wrong programmed
EEPROM on SMPS
Download correct software
4108
Group Fan 1 voltage too low
Call a qualified service engineer
4109
Group Fan 2 voltage too low
Call a qualified service engineer
4110
Group Fan 3 voltage too low
Call a qualified service engineer
R5976654 SLM R12+ 09022004
121
Summary of Contents for SLM R12+ Performer
Page 1: ...EVENTS SLM R12 R9010170 OWNER S MANUAL 09022004 R5976654 00...
Page 4: ......
Page 8: ...Table of contents 4 R5976654 SLM R12 09022004...
Page 38: ...4 Connections 34 R5976654 SLM R12 09022004...
Page 82: ...7 Random Access Adjustment Mode 78 R5976654 SLM R12 09022004...
Page 94: ...8 Installation Mode 90 R5976654 SLM R12 09022004...
Page 112: ...9 Service Mode 108 R5976654 SLM R12 09022004...
Page 114: ...10 Programmable Function Keys 110 R5976654 SLM R12 09022004...
Page 118: ...A Standard Source set up Files 114 R5976654 SLM R12 09022004...