RLM W14 08/20/2014
10
2.General
It is mechanical possible to shift outside the recommended field of view, but it will result in a decline of
image quality depending on the used lens and the zoom position of the used lens. Furthermore, shifting
too much in both directions will result in a blurred image corner.
Best image quality is projected in the On-Axis configuration.
Horizontal and vertical projector tilt ranges
Avoid to reduce the usage of lamp life. Suggest the projector rotated and mounted vertical angle not > ±15°.
Side to side tilt, however, must not exceed ±10°. This limit ensures that the lamp in the projector operates properly and safely.
MAX
A
MAX
MAX
MAX
10°
±15°
±15°
10°
A
B
C
A
Tilting allowed without problems
B
No tilting allowed in this area
C
No tilting allowed in this area
10°
10°
A
2.5 Projector air inlets and outlets
Ventilation inlet:
The internal cooling fan draws cool air from the ventilation inlet into the projector.
Ventilation outlet:
The hot air generated inside the projector is dispersed through the ventilation slot. Make sure the ventilation slot is free from
obstruction.
Ventilation inlet
Ventilation outlet