background image

BARCO PROJECTION SYSTEMS

Date: 19/06/2001

INSTALLATION MANUAL

Rev: 01

DAYLIGHT DISPLAY SYSTEMS

Art. No: R5976153

R9850100
R9850105

Ambient Environment

Controller (AEC)

Summary of Contents for R9850100

Page 1: ...BARCO PROJECTION SYSTEMS Date 19 06 2001 INSTALLATION MANUAL Rev 01 DAYLIGHT DISPLAY SYSTEMS Art No R5976153 R9850100 R9850105 Ambient Environment Controller AEC ...

Page 2: ...rademarks are the rights of their respective owners All rights reserved Produced by BARCO NV 19 06 2001 BARCO n v Daylight Display Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368828 Fax 32 56 368824 e mail sales bps barco com Visit Barco on the web http www barco com Printed in Belgium ...

Page 3: ...g 10 What has to be done 10 Necessary Tools 10 Mounting 10 Image 1 AEC Front 10 Image 2 AEC Mounting attachments on frame 10 Image 3 AEC on top of display structure 11 Connection 12 What has to be done 12 Necessary Tools 12 Interconnection 12 Image 1 Connectors 12 IMPORTANT all plug holder clamps must be locked firmly 12 Image 2 Connection 13 Addressing 14 What has to be done 14 Necessary Tools 14...

Page 4: ...Installation Instructions Contact BARCO if you should have any question regarding the safety of an application The manufacturer assumes no liability for incorrect inadequate irresponsible or unsafe assembly of systems Product Care Structural Mounting Components should be kept dry clean lubricated only if recommended coated properly and otherwise maintained in a manner consistent with part design B...

Page 5: ...r cables and connectors may result in risk of electric shock and risk of fire This equipment MUST be earthed In order to protect against risk of electric shock the installation should be properly grounded Defeating the purpose of the grounding type plug will expose you to the risk of electric shock Power system It is recommended to use a TN S power distribution system a power distribution system w...

Page 6: ... safety purpose of the polarized or grounding type plugs sockets If the provided sockets plugs are damaged then replacement of the defective parts must be undertaken immediately Protect the power data cords from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Replace damaged power data cords immediately Only use attachments ...

Page 7: ...system to detect and configure itself regardless of the shape size and position of AEC modules added to the screen The mechanical flexibility enables easy installation and quick servicing AEC modules are only to be used in conjunction with BARCO DLite Modules Each AEC is assigned a certain representative weighting percentage dependent on it s relevance This percentage weighting can even be assigne...

Page 8: ...EC s Power Box s P C and the Display Tiles All should be interconnected appropriately POWER BOX C CORNER TILE START POINT FOR DATA CONNECTION MAY BE REALIZED IN THE VERTICAL OR HORIZONTAL DIRECTIONS DATA IN MAX 12 POWER OUTPUTS PER BOX POWER SOURCE CABLE OUTLETS P C RS232 OUT DISPLAY Source Signals MONITOR C C C C AEC TO DISPLAY RS232 IN DIGITIZER TO MONITIOR ...

Page 9: ... guidelines Necessary Tools n a For safety reasons it is not recommended to use any other parts than those specified above Power Linking cables connect from tile to tile and tile to AEC Data Linking cables connect from tile to tile and tile to AEC to tile Image 1 Data Power linking cables Power Linking Cable Data Linking Cable Power Linking Cable Data Linking Cable Part Article no Length Image Pow...

Page 10: ... s in the trim are on top or at the side of the DLite Display Necessary Tools Wrench Mounting Follow the next procedure 1 1 2 3 Place the AEC in position and fix to the wall using hammer bolts secure tightly Step Action Image continued on next page Image 2 AEC Mounting attachments on frame Image 1 AEC Front four hammer bolt attachment Front of AEC Display Tile Side ...

Page 11: ...BARCO 11 Daylight Display Systems Image 3 AEC on top of display structure Mounting Continued power and data connections on lower side ...

Page 12: ... next procedure 1 2 3 1 2 2 2 Connect the power out of the last tile in a power chain upto the 6th tile in a power chain with the power in of the AEC Connect the data out of a tile with the data in of the AEC Connect the AEC data out 1 to the data in of the next tile in the data chain Step Action Image power in data in data out 1 not utilised Image 1 Connectors IMPORTANT all plug holder clamps mus...

Page 13: ...ed to all tiles LAST TILE WILL BE IN A CORNER FIRST TILE MAY BE IN ANY CORNER POWER IN DATA OUT DIGITIZER TO DISPLAY COMPLETE DISPLAY NOT SHOWN ONLY THE PRINCIPLE IS DEMONSTRATED POWER BOX MAX 12 POWER OUTPUTS PER BOX POWER SOURCE CABLE OUTLETS DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA DATA daisy chained to maximum 6 tiles per branch AEC 1 DATA IN Image 2 Connection Connection Continu...

Page 14: ...ast tile depending on other devices connected to the display and the number of AEC s A Ambient Controller button will appear in the Main Window Click on this button In the Device Listing you will find all the connected AEC s with their addresses The number next to is the weighting importance given to that AEC The weighting of the AEC s is also displayed in the Resource Sharing window The weights a...

Page 15: ...BARCO 15 Daylight Display Systems Addressing Continued Image 2 AEC s main window ...

Page 16: ... sensors one may perform 100 measurements on each sensor In this way the chart for each sensor is a reference to the measured light of that sensor For example observing one or more sensors having unstable measurements due to the continuously changing light from a spotlight then the sensors may be weighted accordingly Pushing either one of the buttons will reveal the Sensor weight AEC box Select a ...

Page 17: ...BARCO 17 Daylight Display Systems Calibrating Continued Image 1 AEC Calibration Image 2 Information window Image 3 Sensor weighting ...

Page 18: ... the DLite taskbar in the windows taskbar Check the AEC sensing in the Monitor Properties tab Set the polling interval and whether a continuous check or specified interval is required Select the AEC Sensing tab a window appears Here the Reaction Slope can be set This function decides how fast the display will react to the measurements of the AEC s The value is between 0 1 and 1 0 the higher the va...

Page 19: ...BARCO 19 Daylight Display Systems AEC Sensing Continued Image 2 Reaction slope ...