Nio Fusion 12MP

Summary of Contents for Nio Fusion12MP

Page 1: ...ENABLING BRIGHT OUTCOMES MDNC 12130 User guide Nio Fusion 12MP ...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ... operation 22 3 2 Shortcut bar 22 3 3 Standby switching 23 3 4 SoftGlow light mode switching 23 3 5 KVM input switching 24 3 6 OSD menu access and use 24 4 Advanced operation 25 4 1 OSD menu language 26 4 2 OSD menu orientation 26 4 3 OSD menu automatic close function 26 4 4 Power lock function 26 4 5 SoftGlow Task light 27 4 6 SoftGlow Wall light 27 4 7 DPMS mode 28 4 8 Hibernate 28 4 9 Luminance...

Page 4: ...M switch 36 4 22 Grayscale conversion modes 37 4 23 DisplayPort standard version 37 4 24 EDID format 38 4 25 EDID timings 38 4 26 Display info 39 4 27 Display status 39 4 28 SteadyColor 39 4 29 Maximum luminance demo 39 5 Cleaning your display 41 5 1 Cleaning instructions 42 6 Repackaging instructions 43 6 1 Repackaging instructions 44 7 Important information 49 7 1 Safety information 50 7 2 Envir...

Page 5: ...5 R5913350 02 Nio Fusion 12MP 1 1 What s in the box 6 1 2 At a glance 6 1 3 Compatible Barco system components 9 Welcome 1 ...

Page 6: ...for this display and is the ideal protection during transport and storage 1 2 At a glance Product overview 6 3 5 1 2 10 9 4 7 8 Image 1 1 1 Ambient light sensor and Power status LED Dimmed Display not powered mains cable unplugged or power switch in OFF position or display is in normal operation Fast blinking amber Display is entering DPMS mode Slow blinking amber Display is in DPMS mode Steady am...

Page 7: ... is disabled Switch KVM inputs when the KVM switch is enabled 4 Side USB A 2 0 downstream connector 5 SoftGlow Wall light 6 SoftGlow Task light 7 Connector cover 8 VESA mount cover 9 Cable routing channels 10 Stand locking mechanism Connectors One USB connector is available on the side of the display To access the bottom connectors gently pull the bottom of the connector cover away from the displa...

Page 8: ...tch 15 DisplayPort IN 2 also Secondary for KVM switch 16 Kensington security slot 17 100 240 VAC mains power input and power switch Display position adjustment After unpacking you can safely tilt and swivel the display to your preferred position Image 1 4 To adjust the height of the display first move the slider at the back of the stand to the unlock position Then you can raise or lower the displa...

Page 9: ...ew Following Barco components are compatible with your Nio Fusion 12MP display QAWeb Enterprise version 2 5 or later or MediCal QAWeb version 1 13 20 or later MXRT x700 range or later display controllers The older MXRT 5600 and MXRT 7600 display controllers are also supported but only for a single workstation setup Dual workstation setup with KVM switch is not supported with these display controll...

Page 10: ...R5913350 02 Nio Fusion 12MP 10 Welcome ...

Page 11: ... Fusion 12MP 2 1 Single workstation setup 12 2 2 Dual workstation setup with KVM switch 13 2 3 QAWeb registration 16 2 4 VESA mount installation 16 2 5 VESA mount installation in portrait mode 19 Installation and setup 2 ...

Page 12: ...er guide on the included documentation CD or at www barco com support Connect the cables 1 Remove the connector cover 2 Connect the DisplayPort inputs DP IN 1 and DP IN 2 with the DisplayPort outputs on the workstation 3 Connect the main USB upstream connector USB UP 1 with a USB host on the workstation to make use of QAWeb or a peripheral keyboard mouse touchpad etc connected to one of the displa...

Page 13: ... mxrt 2 Install the MXRT driver and Intuitive Workflow Tools as described in the Barco Display Controller and Intuitive Workflow Tools user guide on the included documentation CD or at www barco com support 2 2 Dual workstation setup with KVM switch About In this setup the display is connected to two different workstations each with one DisplayPort cable When connecting a USB cable from your displ...

Page 14: ...nnect the main USB upstream connector USB UP 1 with a USB host on workstation 1 4 Connect DisplayPort input 2 DP IN 2 with the DisplayPort output on workstation 2 5 Connect the secondary USB upstream connector USB UP 2 with a USB host on workstation 2 Note The USB UP 2 connector is covered by a plastic cap which has to be removed first 6 Connect a keyboard and mouse or another peripheral used to c...

Page 15: ...mxrt 2 Install the MXRT driver and Intuitive Workflow Tools as described in the Barco Display Controller and Intuitive Workflow Tools user guide on the included documentation CD or at www barco com support Adjust EDID format and timings The EDID format must be set to DisplayID 1 3 and the EDID resolution timing must be set to 12MP i e 4200 x 2800 for both DisplayPort inputs in order to drive the f...

Page 16: ...xpanding healthcare enterprise with less effort lower cost and complete confidence This fully automated and secure system guarantees a consistent image quality and uptime for all registered imaging display systems within your facility and across your enterprise Learn more at www barco com qaweb To register your display system to your QAWeb Enterprise organization the QAWeb Enterprise Agent must be...

Page 17: ...If you re not using a mount you can skip this chapter 1 Unlock the stand locking mechanism and put the display in the highest position Image 2 5 2 Put the display face down on a clean and soft horizontal surface Be careful not to damage the panel screen 3 Push the VESA mount cover to the right and lift the cover on the right with your finger or a flathead screwdriver Image 2 6 4 Push the VESA moun...

Page 18: ...ws fixing the panel to the stand Image 2 8 6 Unscrew the 4 fixation screws while supporting the stand Image 2 9 7 Attach the panel firmly to the VESA mount using 4 M4 screws Respect the following rule to select an appropriate screw length Lmin T W 6 5 mm Lmax T W 10 mm Installation and setup ...

Page 19: ...tions can also be used to mount the display in portrait position on the existing display stand 2 Connect the display to your workstation When using the display in portrait position only one DisplayPort cable can be connected This will give you the full resolution at reduced refresh rate but with just one Windows taskbar at the bottom of the screen 3 For your convenience align the display s OSD men...

Page 20: ...R5913350 02 Nio Fusion 12MP 20 Installation and setup ...

Page 21: ...Nio Fusion 12MP 3 1 Recommendations for daily operation 22 3 2 Shortcut bar 22 3 3 Standby switching 23 3 4 SoftGlow light mode switching 23 3 5 KVM input switching 24 3 6 OSD menu access and use 24 Daily operation 3 ...

Page 22: ...image retention of the static elements Understand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performance of the product To ensure optimal product quality Barco applies strict selection criteria for its LCD panels Enhance...

Page 23: ...ching About the SoftGlow lights The SoftGlow Task light sheds a light on the desktop while the SoftGlow Wall light provides ambient lighting for the reading room to reduce eye fatigue The brightness of each is adjustable To switch the SoftGlow light mode 1 Press or turn the jog dial to activate the shortcut bar The SoftGlow lights icon is selected by default when the KVM switch is disabled 2 If no...

Page 24: ... is selected by default when the KVM switch is enabled When switching KVM inputs the video is switched instantly while switching the USB signal might take a little longer up to 2 seconds 3 6 OSD menu access and use About the OSD menu The OSD menu allows you to configure different settings to make your Nio Fusion 12MP fit your needs within your working environment Also you can retrieve general info...

Page 25: ...ded QA 33 4 19 Image scaling 35 4 20 Image source selection 36 4 21 KVM switch 36 4 22 Grayscale conversion modes 37 4 23 DisplayPort standard version 37 4 24 EDID format 38 4 25 EDID timings 38 4 26 Display info 39 4 27 Display status 39 4 28 SteadyColor 39 4 29 Maximum luminance demo 39 About This section describes all settings available in the OSD menu and how to change and configure them Certa...

Page 26: ...menu 3 Enter the Orientation submenu 4 Select Landscape Portrait or Inverse Portrait and confirm 4 3 OSD menu automatic close function About the OSD menu automatic close function By default the OSD menu will disappear automatically after approximately 90 seconds of inactivity However this function can be disabled so that the OSD menu remains on the screen until manually closed To enable disable th...

Page 27: ...ntation CD or at www barco com support To adjust the SoftGlow Task light brightness 1 Bring up the OSD main menu 2 Navigate to the Configuration Lights menu 3 Enter the SoftGlow Task Light brightness submenu 4 Set a SoftGlow Task Light brightness value as desired and confirm The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools See the Barco Display Controller and ...

Page 28: ...ay but it also needs to be activated on your workstation To do this go to the Power options of your workstation Barco recommends setting DPMS activation after 20 minutes of non usage When DPMS mode is enabled an additional power saving function becomes available hibernate See Hibernate page 28 for more information To enable disable DPMS mode on your display 1 Bring up the OSD main menu 2 Navigate ...

Page 29: ...ce target 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration menu 3 Enter the Luminance Target submenu 4 Set a luminance target value as desired and confirm The default factory calibrated luminance value is available in the technical specifications table The guaranteed backlight lifetime is valid for this setting 4 10 Color presets About color presets The available color pres...

Page 30: ...avigate to the Configuration Calibration Color Settings Color Presets menu 3 Select User and confirm 4 Enter the Color Definition submenu select Color Coordinates and confirm 5 Enter the x and y submenus set the values as desired and confirm 4 11 Color space About color space The available color space settings for your display are sRGB standard Red Green Blue To match typical home and office viewi...

Page 31: ...ur display are Native The native panel behavior will not be corrected Dynamic Gamma 1 8 or 2 2 These are gamma functions that are shifted to take into account the non zero luminance of an LCD panel when driven with a black signal They are especially useful in CTapplications to improve the perception of low Hounsfield values DICOM DICOM Digital Imaging and Communications in Medicine is an internati...

Page 32: ...ight correction value into account This value is determined by the selected reading room Therefore it is also important to select a realistic reading room when enabling ALC This can be done by following the instructions in Reading rooms page 32 To enable disable ALC 1 Bring up the OSD main menu 2 Navigate to the Configuration Calibration Ambient Light menu 3 Enter the Ambient Light Compensation su...

Page 33: ... Enter the Reading Room submenu 4 Select one of the available reading rooms and confirm 4 17 Continuous Ambient Light Compensation ALC About Continuous ALC Enabling continuous ALC will continuously recalculate the DICOM display function taking the averaged ambient light as measured by the integrated ambient light sensor into account Continuous ALC can only be enabled on your display when the displ...

Page 34: ...isplay Function Shows the current display function Ambient light compensation Shows the ambient light compensation status Reading Room Shows the selected reading room Luminance Shows the measured luminance Black luminance Shows the measured black luminance DICOM Calibration Status No calibration executed yet No other information is visible Calibration executed When the calibration is executed the ...

Page 35: ...menu 3 Enter the DICOM Preferences submenu 4 Select Reset DICOM Calibration to restore the original not corrected DICOM curve 4 18 6 DICOM error threshold About DICOM error threshold The threshold to define the DICOM compliance can be modified in steps of 5 starting from 5 to 30 When the maximum deviation is not bigger than the selected threshold the compliance check will be OK To set the DICOM er...

Page 36: ...iguration Image Sources menu 3 Enter the Image Source Selection submenu 4 Select one of the following image source selection modes and confirm One Image Source Allows to select one image source to display Two Image Sources Displays DisplayPort IN 1 on the left side and DisplayPort IN 2 on the right side of the screen Expert mode Allows to select for the left and right side of the screen which imag...

Page 37: ...mode is possible but then your display s image source selection mode should be set to allow this Refer to Image source selection page 36 to do this About grayscale conversion modes Grayscale conversion modes specify how color generated on the display controller is converted to grayscale in your display The available grayscale conversion modes are No conversion Use Red Channel This mode is intended...

Page 38: ...th KVM switch page 13 To set the EDID format 1 Bring up the OSD main menu 2 Navigate to the Configuration Image Sources Input Settings DisplayPort 1 2 menu 3 Enter the EDID format submenu 4 Select one of the available formats and confirm 4 25 EDID timings About EDID timings Following EDID timings are available for your Nio Fusion 12MP Resolution Allows to manually modify the resolution of the imag...

Page 39: ...nearity in the display of color images With multiple internal sensors the display parameters are constantly monitored and adjusted to ensure that the perceptual difference between colors is proportional with their Digital Driving Level DDL difference To enable SteadyColor SteadyColor is controlled via Barco s QAWeb Enterprise software or the older MediCal QAWeb To register to QAWeb Enterprise or t...

Page 40: ... Service menu 5 Navigate to the Maximum Luminance demo submenu and confirm The maximum luminance demo is activated 6 Press the jog dial to manually cancel the maximum luminance demo or wait for 60 seconds after which the demo is automatically cancelled Advanced operation ...

Page 41: ...41 R5913350 02 Nio Fusion 12MP Cleaning your display 5 ...

Page 42: ...ut a certain cleaning product use plain water Do not use any of the following products Alcohol in concentrations 70 Strong alkalis lye strong solvents Acetone Toluene Acids Detergents containing fluoride Detergents containing ammonia Detergents containing abrasives Steel wool Sponge with abrasives Steel blades Cloths with steel thread Paper based cloths e g paper towels facial tissues toilet paper...

Page 43: ...43 R5913350 02 Nio Fusion 12MP Repackaging instructions 6 ...

Page 44: ...Put the display in the lowest position and lock the stand locking mechanism Image 6 1 2 Place the display in the bottom buffer on a stable surface Caution It takes 2 persons to safely execute this action x2 Image 6 2 3 Insert the rear buffer in the bottom buffer Repackaging instructions ...

Page 45: ...45 R5913350 02 Nio Fusion 12MP Image 6 3 4 Position the front buffer Image 6 4 5 Slide the accessory box es and all cables in the dedicated cavities Repackaging instructions ...

Page 46: ...R5913350 02 Nio Fusion 12MP 46 Image 6 5 6 Slide the display and the accessories in the box Image 6 6 7 Close and seal the box Repackaging instructions ...

Page 47: ...47 R5913350 02 Nio Fusion 12MP Image 6 7 Repackaging instructions ...

Page 48: ...R5913350 02 Nio Fusion 12MP 48 Repackaging instructions ...

Page 49: ...ation 50 7 2 Environmental information 51 7 3 Regulatory compliance information 53 7 4 EMC notice 54 7 5 Explanation of symbols 57 7 6 Legal disclaimer 60 7 7 Open source license information 60 7 8 Technical specifications 61 Important information 7 ...

Page 50: ...d part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the same time Power connection Equipment with internal power supply This equipment must be earthed Power requirements The equipment must be powered by the AC mains voltage The equipment should be installed near an easil...

Page 51: ...wed Adjust only those controls that are covered by the operating instructions since improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation If the equipment has been dropped or the cabinet has been damaged If the product exhibits a distinct change in performance indicating a need for servi...

Page 52: ...名称 Component name 有毒有害物质或元素 Hazardous substances and elements 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr6 多溴联苯 PBB 多溴二苯醚 PBDE 印制电路配件 Printed Circuit Assemblies x o o o o o 液晶面板 LCD panel x o o o o o 外接电 线 缆 External Cables x o o o o o 內部线路 Internal wiring o o o o o o 金属外壳 Metal enclosure o o o o o o 塑胶外壳 Plastic enclosure o o o o o o 散热片 器 Heatsinks o o o o o o 电源供应器 Power Supply Unit x o o o o o 风扇 Fan o o o o o o 文件...

Page 53: ... of this document 7 3 Regulatory compliance information Indications for use The display is intended to be used in displaying and viewing digital images including standard and multiframe digital mammography for review analysis and diagnosis by trained medical practitioners It is specially designed for breast tomosynthesis applications Intended usage environment The display is not in contact with pa...

Page 54: ...ferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC responsible Barco Inc 3059 Premiere Parkway Suite 400 30097 Duluth GA United States Tel 1 678 475 8000 Canadian notice CAN ICES 1 NMB...

Page 55: ...ient or relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced technician for help Electromagnetic immunity The Nio Fusion 12MP is intended for use in the electromagnetic environment specified below The custome...

Page 56: ...a typical commercial or hospital environment Conducted RF IEC 61000 4 6 3 Vrms 6 Vrms in ISM bands 150 kHz to 80 MHz 3 Vrms 6 Vrms in ISM bands Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 7 GHz 3 V m Immunity to RF wireless communications equipment Test frequency MHz Band MHz Service Modulation Maximum power W Distance m Immunity test level V m 385 380 390 TETRA 400 Pulse modulation 18 Hz 1 8 0 3 ...

Page 57: ...e with Part 15 of the FCC rules Class A or Class B Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US E352529 Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approved accord...

Page 58: ... approved according to the BIS regulations Indicates the device is approved according to the INMETRO regulations Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the legal manufacturer Indicates the manufacturing date yy xx Indicates the temperature limitations4 for the device to safely operate within specs MD Indicates this is a Medical Devic...

Page 59: ...ground Symbols on the box On the box of the device you may find the following symbols nonrestrictive list Indicates a device that can be broken or damaged if not handled carefully when being stored Indicates a device that needs to be protected from moisture when being stored Indicates the storage direction of the box The box must be transported handled and stored in such a way that the arrows alwa...

Page 60: ...ifications of Barco products are subject to change without notice Trademarks All trademarks and registered trademarks are property of their respective owners Copyright notice This document is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopying taping or informa...

Page 61: ...n to continue to provide service warranties software updates fixes maintenance access or such similar abilities without any recourse or claim towards Barco whatsoever Barco offers to provide the corresponding source code and shall make the corresponding source code available to you via email or download link except where the applicable license entitles you to require Barco to provide you the corre...

Page 62: ...w o stand W x H x D 695 x 483 x 74 mm Dimensions packaged W x H x D 800 x 650 x 295 mm Net weight with stand 16 6 kg Net weight w o stand 12 0 kg Net weight packaged 21 3 kg without optional accessories Tilt 5 to 25 Swivel 30 to 30 Pivot N A Height adjustment range 100 mm Mounting standard VESA 100 mm Screen protection N A Recommended modalities All digital images including digital mammography and...

Page 63: ... please refer to the product page on www barco com or see the certification marks on the product label of your display Supplied accessories User guide Documentation disc System sheet Video cables USB cables Mains cables Optional accessories Display controller QA software QAWeb Warranty 5 years including 40000 hrs backlight warranty Operating temperature 0 C to 35 C 20 C to 30 C within specs Storag...

Page 64: ...R5913350 02 Nio Fusion 12MP 64 Relation of storage and operating humidity and temperature Image 7 1 Important information ...

Page 65: ......

Page 66: ...www barco com R5913350 02 2021 01 26 Barco NV President Kennedypark 35 8500 Kortrijk Belgium ...