C. Troubleshooting
Error
code
Description
Error
Warn-
ing
Caused by
Action
7980
Blue DMD
temp high
Yes
Yes
high temperature on dmd
check if air slot are free; clean air
filters
If problem persists, call a qualified
service engineer
7978
Lamp temp
high
Yes
Yes
high temperature lamp
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
7976
SMPS HS
temp high
Yes
Yes
high temperature on smps
check if air slot are free; clean air
filters If problem persists, call a
qualified service engineer
7974
Ambient temp
high
Yes
Yes
ambient temperature above
specification
check ambient conditions
check if air slot are free; clean air
filters
7973
Fan 1 voltage
low
Yes
Yes
voltage on fan group 1 too low (=
cathode fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7972
Fan 1 voltage
high
-
Yes
voltage on fan group 1 too high
Hardware problem in Fan control
board, call a qualified service
engineer
7971
Fan 2 voltage
low
Yes
Yes
voltage on fan group 2 too low (=
anode fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7970
Fan 2 voltage
high
-
Yes
voltage on fan group 2 too high
Hardware problem in Fan control
board, call a qualified service
engineer
7969
Fan 3 voltage
low
Yes
Yes
voltage on fan group 3 too low (=
engine fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7968
Fan 3 voltage
high
-
Yes
voltage on fan group 3 too high
Hardware problem in Fan control
board, call a qualified service
engineer
7967
Fan 4 voltage
low
Yes
Yes
voltage on fan group 4 too low (=
cold head ex. fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7966
Fan 4 voltage
high
-
Yes
voltage on fan group 4 too high (=
cold head ex. fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7965
Fan 5 voltage
low
Yes
Yes
voltage on fan group 5 too low (=
mains input fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7964
Fan 5 voltage
high
-
Yes
voltage on fan group 5 too high
mains input fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7963
Fan 6 voltage
low
Yes
Yes
voltage on fan group 6 too low (=
smps fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7962
Fan 6 voltage
high
-
Yes
voltage on fan group 6 too low (=
smps fan)
Hardware problem in Fan control
board, call a qualified service
engineer
7959
Pump voltage
low
Yes
Yes
voltage on pump too low
If problem persists, call a qualified
service engineer
7958
Pump voltage
high
-
Yes
voltage on pump too high
If problem persists, call a qualified
service engineer
172
R5976986 FLM HD18 01/09/2006
Summary of Contents for FLM HD18
Page 1: ...FLM HD18 Users manual R9004450 R5976986 00 01 09 2006...
Page 4: ......
Page 44: ...5 Connections 40 R5976986 FLM HD18 01 09 2006...
Page 56: ...6 Getting started 52 R5976986 FLM HD18 01 09 2006...
Page 90: ...9 Image menu 86 R5976986 FLM HD18 01 09 2006...
Page 134: ...13 Projector control 130 R5976986 FLM HD18 01 09 2006...
Page 166: ...17 Removal of the projector covers 162 R5976986 FLM HD18 01 09 2006...
Page 170: ...A Dimensions 166 R5976986 FLM HD18 01 09 2006...
Page 186: ...E Order info 182 R5976986 FLM HD18 01 09 2006...