4.6 Resetting the lamp parameters
CAUTION:
The
“
LAMP INFO
”
parameters MUST be updated after each installation of a xenon lamp
inside the Lamp House. Neglecting this update will result in poor performance and short life time of
the xenon lamp.
How to reset the lamp parameters?
1.
Start up the projector but do not ignite the lamp.
2.
Go via the
Communicator
touch panel to the menu
“
Installation
”
>
“
Lamp
”
>
“
Lamp information
”
.
3.
While the
Lamp information
window is displayed, tap on
Reset
(1).
A reset message is displayed (2).
4.
Tap on
Select
(3) to display a list of possible article numbers (4). Select a article number (5) and tap
OK
(6).
The software will validate the selected article number (7).
5.
Fill out the serial number of the lamp (8).
6.
Click
Reset
(9).
Image 4
–
26 Reset lamp info
CAUTION:
For more information about using the Communicator Touch Panel consult the user's
guide of the Communicator Touch Panel.
Summary of Contents for DP2K C
Page 1: ...ENABLING BRIGHT OUTCOMES User and Installation manual For DP2K 12C DP2K 15C DP2K 20C DP2K C...
Page 6: ......
Page 10: ...R5905752 16 DP2K C 10...
Page 38: ...R5905752 16 DP2K C 38 Physical installation...
Page 56: ...R5905752 16 DP2K C 56 Lamp Lamp House...
Page 82: ...R5905752 16 DP2K C 82 Input communication...
Page 84: ...R5905752 16 DP2K C 84 Image 7 1 ICMP X...
Page 120: ...R5905752 16 DP2K C 120 Communicator touch panel...
Page 162: ...R5905752 16 DP2K C 162 Specifications...
Page 174: ...R5905752 16 DP2K C 174 Environmental information...
Page 178: ...R5905752 16 DP2K C 178 Glossary...
Page 183: ......