R5905752 /16
DP2K C
50
Image 4
–
20 Secure UV blocker
9.
Fasten the cathode side of the xenon lamp using a hexagon socket head screw M6 x 40 and a plain
washer as illustrated. Use a torque of
2,5 Nm
(1,84 lbf*ft) to fasten the hexagon socket head screw. Use
for that a torque wrench with a 5 mm Allen socket.
Caution:
Make sure that the both pins of the cathode adapter remain engaged in the foreseen
slots. Use one hand to keep the xenon lamp into position while inserting the hexagon socket
head screw.
2,5 Nm
10
Image 4
–
21 Fasten cathode side
10.
Check the cathode connection inside the Lamp House. Use a 17 mm open-end wrench to hold the first nut
while fastening the second nut on the rod with a torque of
9 Nm
(6,64 lbf*ft) using a torque wrench with 17
mm hexagon socket. Ensure that there is a flat washer (reference 3) between the lock nut and the wire lug.
Caution:
This cathode connection must be checked with every lamp change!
Caution:
Do not tighten the first nut (reference 1) against the connector housing. There must be
some play (1 mm maximum). This is important to insert the Lamp House smoothly into the
projector.
Summary of Contents for DP2K C
Page 1: ...ENABLING BRIGHT OUTCOMES User and Installation manual For DP2K 12C DP2K 15C DP2K 20C DP2K C...
Page 6: ......
Page 10: ...R5905752 16 DP2K C 10...
Page 38: ...R5905752 16 DP2K C 38 Physical installation...
Page 56: ...R5905752 16 DP2K C 56 Lamp Lamp House...
Page 82: ...R5905752 16 DP2K C 82 Input communication...
Page 84: ...R5905752 16 DP2K C 84 Image 7 1 ICMP X...
Page 120: ...R5905752 16 DP2K C 120 Communicator touch panel...
Page 162: ...R5905752 16 DP2K C 162 Specifications...
Page 174: ...R5905752 16 DP2K C 174 Environmental information...
Page 178: ...R5905752 16 DP2K C 178 Glossary...
Page 183: ......