87
R5905752 /16
DP2K C
012
345
678
9
ICMP-
X
Image 7
–
6
An upgraded ICMP with GEN 2 storage controller has a label
“
SSD READY - RAID GEN2
”
applied under the
Barco logo). This sticker comes with the upgrade kit; it will only be there when the
“
upgrader
”
applied it.
Image 7
–
7
It
’
s useful to recognize an ICMP from an ICMP-X or upgraded ICMP to know which HDDs can be
used without re-initialization.
7.2 ICMP-X HDD
About ICMP-X HDD
The three HDDs (local storage) in the ICMP-X, are set up in a RAID 5 configuration. This storage technique,
that combines multiple HDD components into a logical unit, manages enough redundancy information to
continue to operate properly after the loss of one HDD.
Image 7
–
8
CAUTION:
A RAID 5 configuration with three HDDs allows a maximum loss of one disk. With the
simultaneous loss of more than one HDDs, data is lost and the RAID must be completely initialized
again after replacement of the defect HDDs with new HDDs!
About degraded mode
When a RAID array experiences the failure of one disk, it enters in degraded mode. Content storage and
playback remains available on the ICMP-X.
Summary of Contents for DP2K C
Page 1: ...ENABLING BRIGHT OUTCOMES User and Installation manual For DP2K 12C DP2K 15C DP2K 20C DP2K C...
Page 6: ......
Page 10: ...R5905752 16 DP2K C 10...
Page 38: ...R5905752 16 DP2K C 38 Physical installation...
Page 56: ...R5905752 16 DP2K C 56 Lamp Lamp House...
Page 82: ...R5905752 16 DP2K C 82 Input communication...
Page 84: ...R5905752 16 DP2K C 84 Image 7 1 ICMP X...
Page 120: ...R5905752 16 DP2K C 120 Communicator touch panel...
Page 162: ...R5905752 16 DP2K C 162 Specifications...
Page 174: ...R5905752 16 DP2K C 174 Environmental information...
Page 178: ...R5905752 16 DP2K C 178 Glossary...
Page 183: ......