![background image](http://html1.mh-extra.com/html/barco/clm-hd8-r9050130/clm-hd8-r9050130_user-manual_4031414178.webp)
D. Troubleshooting
Error
code
Description
Error
Warn-
ing
Caused by
Action
2005
Lamp stop
failed
Yes
-
Call qualified service engineer
2100
LPS 1 error
Yes
-
Replace LPS
2400
LPS 2 error
Yes
-
Replace LPS
2700
LPS 3 error
Yes
-
Replace LPS
3000
LPS 4 error
Yes
-
Replace LPS
3899
Spi flash
invalid type
Yes
3898
Spi flash busy
Yes
3999
IR buffer full
Yes
4000
Incompatible
hardware
Yes
No
Incompatible hardware used
Change to correct hardware
4199
FIB reset
failed
Yes
-
no communication with FIB
Call a qualified service engineer
4198
FPGA PMP
init failed
Yes
-
6099
Board ID
unkown
version
Yes
6098
Board ID
invalid string
Yes
7999
DMD temp low
Yes
Yes
Low temperature on DMD
turning on the lamp(s) will heat up
the DMD
7998
DMD temp
high
Yes
Yes
High temperature on DMD
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7997
Ambient temp
low
Yes
Yes
Ambient temperature out of
specifications
take measurements to increase the
temperature
7996
Ambient temp
high
Yes
Yes
Ambient temperature out of
specifications
check ambient conditions
check if air slots are free, clean air
filter.
7994
TEC temp
high
Yes
Yes
7992
LPS1 temp
high
Yes
Yes
High temperature on LPS1
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7990
LPS2 temp
high
Yes
Yes
High temperature on LPS2
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
7988
LPS3 temp
high
Yes
Yes
High temperature on LPS3
check if air slots are free, clean air
filters.
If problem persists, call a qualified
service engineer.
174
R59770057 CLM HD8 16/07/2007
Summary of Contents for CLM HD8 R9050130
Page 1: ...CLM HD8 User guide R9050130 R90501301 R59770057 00 16 07 2007...
Page 4: ......
Page 22: ...2 General 18 R59770057 CLM HD8 16 07 2007...
Page 34: ...3 Physical installation 30 R59770057 CLM HD8 16 07 2007...
Page 46: ...5 Connections 42 R59770057 CLM HD8 16 07 2007...
Page 58: ...6 Getting started 54 R59770057 CLM HD8 16 07 2007...
Page 92: ...9 Image menu 88 R59770057 CLM HD8 16 07 2007...
Page 154: ...15 Maintenance 150 R59770057 CLM HD8 16 07 2007...
Page 164: ...16 Servicing 160 R59770057 CLM HD8 16 07 2007...
Page 188: ...E Mounting optional Carry handle 184 R59770057 CLM HD8 16 07 2007...
Page 190: ...F Order info 186 R59770057 CLM HD8 16 07 2007...