D. Troubleshooting
D. TROUBLESHOOTING
D.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warn-
ing
Caused by
Action
1000
Wrong lamp
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1399
I²C open error
Yes
1398
I²C read error
Yes
1397
I²C write error
Yes
1499
Video input
invalid
1498
1699
Formatter
busy
1698
Formatter
address
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1695
Formatter
start failed
Yes
-
no communication with formatter
Call a qualified service engineer
1694
Formatter
PWGGood
Yes
-
formatter ’Power Good’ signal not
OK
Call a qualified service engineer
1999
MAX7301 not
initialized
Yes
2000
No lps
detected
Yes
-
no communication with lamp power
supply
Call a qualified service engineer
2001
Mains voltage
too low
Yes
-
mains voltage too low
2002
Lamp start
failed
Yes
-
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
2003
Main voltage
too high
Yes
-
mains voltage too high
2004
Lamp goes out
Yes
-
Call qualified service engineer
R59770057 CLM HD8 16/07/2007
173
Summary of Contents for CLM HD8 R9050130
Page 1: ...CLM HD8 User guide R9050130 R90501301 R59770057 00 16 07 2007...
Page 4: ......
Page 22: ...2 General 18 R59770057 CLM HD8 16 07 2007...
Page 34: ...3 Physical installation 30 R59770057 CLM HD8 16 07 2007...
Page 46: ...5 Connections 42 R59770057 CLM HD8 16 07 2007...
Page 58: ...6 Getting started 54 R59770057 CLM HD8 16 07 2007...