9. Image menu
The timings menu will be displayed.
Image 9-63
Image 9-64
Image 9-65
4. To change a setting, use the
▲
or
▼
key to select and press
ENTER
.
The corresponding adjustment box is displayed. E.g. Horizontal total pixels.
Image 9-66
5. Use the
▲
or
▼
key (or
◄
or
►
key) to change the value.
6. Press
ENTER
to activate the new value.
7. If necessary to change other settings, repeat from step 4.
9.5.2
Advanced settings
About the advanced settings
Clamp delay
The time between the leading edge of the clamp pulse and the locked edge of the sync pulse. Can be
any value between 0 and 255.
Clamp width
The width of the clamp pulse can be any value between 0 and 255.
Sync
pulse
Clamp
pulse
Clamp
delay
Clamp
width
Le
ad
ing e
dge
Tr
ailinging e
dge
Image 9-67
Field polarity
The field polarity function is used for interlaced images. Both rasters of the image could be shifted in
a wrong way (double lines are visible in the image). This can be corrected by forcing the field polarity
to [neg] or [pos].
80
R59770057 CLM HD8 16/07/2007
Summary of Contents for CLM HD8 R9050130
Page 1: ...CLM HD8 User guide R9050130 R90501301 R59770057 00 16 07 2007...
Page 4: ......
Page 22: ...2 General 18 R59770057 CLM HD8 16 07 2007...
Page 34: ...3 Physical installation 30 R59770057 CLM HD8 16 07 2007...
Page 46: ...5 Connections 42 R59770057 CLM HD8 16 07 2007...
Page 58: ...6 Getting started 54 R59770057 CLM HD8 16 07 2007...
Page 92: ...9 Image menu 88 R59770057 CLM HD8 16 07 2007...
Page 154: ...15 Maintenance 150 R59770057 CLM HD8 16 07 2007...
Page 164: ...16 Servicing 160 R59770057 CLM HD8 16 07 2007...
Page 188: ...E Mounting optional Carry handle 184 R59770057 CLM HD8 16 07 2007...
Page 190: ...F Order info 186 R59770057 CLM HD8 16 07 2007...