Source connections
6 - 5
5976397 SPLIT PACK REALITY 909 09112001
75
W
Termination resistors
In case of chaining (loop-through) the projectors, the 75
W
line termination resistors must be removed from the second RGB Input
Module when the projector is NOT the last unit in the chain.
In case of a stand-alone projector, do not remove the resistors.
75
W
resistors on the module
:
line terminated.
75
W
resistors removed
:
line not terminated.
Removing the termination resistors
1 Turn off the projector and unplug the projector power cord.
2 Remove the protection plate on top of the electric block.
3 Remove the RGB Input Module from the main frame.
4 Unsolder and remove the resistors.
Blue in green switch
Blue characters are difficult to read, therefore the blue text will be displayed as cyan so that the readability becomes better.
Switch in the ON position
:
Blue in Green active.
Switch in the OFF position
:
Blue in Green disabled.
Warning
Leaving the switch in the ON position will result in abnormal color balance of the projected image.
Force negative sync Switch
Switch in the ON position
:
the sync pulses must be negative.
Switch in the OFF position
:
the sync polarity will be automatically detected.
How to remove the second RGB module ?
When removing the second RGB module, turn off the projector and unplug the power cord from the wall outlet.
1. Loosen the two bolts on each side of the projector (image 6.8).
2. Lift up the protection plate (image 6.8).
3. The second RGB module is located in the slot 4 of the main frame (image 6.8).
4. Press the module locks (A image 6.8) and lift up the module handles (B image 6.8) on both sides of the module.
5. Disconnect the mini-connector J3 (image 6.8) on the printed circuit board in slot 2, for easy handling, repeat step 4 to lift up this
printed circuit board.
(Remark: when an optional Limo Plus is installed, the mini-connector is connected to the Limo Plus print in slot 3).
6. Extract the module out of the main frame.
7. When finished, reconnect mini-connector J3, secure the printed circuit boards and put back the protection plate.
image 6.8
Removing the second RGB module
Slot 1
Slot 2
J3
Slot 3
A
B
Slot 4
Summary of Contents for BarcoReality 909 Split Pack R9040040
Page 1: ...SPLIT PACK REALITY 909 R9040040 INSTALLATION MANUAL...
Page 2: ......
Page 8: ...Table of contents 0 4 5976397 SPLIT PACK REALITY 909 09112001...
Page 18: ...Packing and dimensions 2 6 5976397 SPLIT PACK REALITY 909 09112001...
Page 30: ...Installation setup 4 6 5976397 SPLIT PACK REALITY 909 09112001...
Page 34: ...ACPowerconnections 5 4 5976397 SPLIT PACK REALITY 909 09112001...
Page 42: ...Sourceconnections 6 8 5976397 SPLIT PACK REALITY 909 09112001...
Page 58: ...i 2 Index 5976397 SPLIT PACK REALITY 909 09112001...