USE AND CARE INSTRUCTIONS
16
Secure a 20lb LP Gas Tank to Gas Grill
Note:
You can only use a 20lb LP Gas Tank in this
Gas Grill.
NOTE:
When using Propane, EXTREME CAUTION
should be used to provide ample ventilation of vapor
from the enclosure. LP Gas vapor is heavier than air
and SERIOUS INJURY from a DANGEROUS EXPLO-
SION could occur if LP Gas is allowed to accumulate
in an enclosure and then ignited. Both the Barbecue
enclosure and LP cylinder enclosure require venting
that must be provided at the floor level of the enclo-
sure to allow any leaking LP Gas vapor to escape
(see Fig. 1).
NOTE:
When installing a barbecue equipped for liquid
propane in an island, the propane tank must be in
a separate enclosure that is completely isolated from
the barbecue. It must be cross-ventilated in accor-
dance with the current standards. The propane tank
MUST NEVER be installed directly under the barbe-
cue.
NOTE: The total of the upper ventilation openings
must be a minimum of 20 sq. inches. The total of
the lower ventilation openings must be a minimum
of 10 sq. inches. Upper and lower ventilation open-
ings MUST BE PROVIDED on both sides of built-in
construction. The top of the upper ventilations open-
ings must be located within 5" from the top of the
island. The bottom of the lower ventilation openings
must be at least 1" or less from the floor of the island.
The top of the lower ventilation openings cannot be
more than 5" from the floor of the island. Every
ventilation opening must have a minimum of 1/8" (See
Fig. 4 on page 22). Contact a
Barbeques Galore
’
s
associate for more details.
Fig. 1
Stainless Steel Tube (Refer
to the Note below).
5/8" UNF
Thread
The built-in appliance for use with a remote self-contained LP
Gas supply system must use rigid pipe, semi-rigid tubing or a
connector complying with the Standard for Connections for
Gas Appliances, ANSI Z21.24/CSA6.10, or the standard for
Connectors Outdoor Gas Appliance and Manufactured
Homes, ANSI21.75/CSA 6.27 and suitable for outside installa-
tion. The maximum length of the connection shall be 6 ft(1.
82m).
The connector should be installed at the location visible
when opening the door.
The connector must be away from any sharp points or sharp
edges.
When using semi-rigid tubing, do not use materials made of
aluminium or aluminium alloy.
Note:
Air Vents
Partition Panel
Non-Combustible
Construction, such as
stone, marble, cement