2.6.3
Overview of the connections on the gas regulator block
B
A
C
M
D
E
G
F
H
L
K
J
I
A
Pilot light pipe
B
Thermocouple
C
Connector (nut-olive) Ø 4mm
D
Thermocouple interrupter
1
E
Connector of gas valve of the rear
burner
F
Gas pipe to rear burner
G
Connector (nut-olive) Ø 8 mm
H
Gas valve of the rear burner
I
Control cable of the gas valve of the
rear burner
2
J
Olive Ø 8mm
K
Nut Ø 8mm
L
Gas supply connection
M
Gas pipe front burner
Figure 6. Connections on the gas regulator block
1
Interrupts the signal of the thermocouple, and bypasses this signal through the receiver. When the
thermocouple signal is cut off by the receiver (requested by the remote control) or when the
thermocouple signal is weak or broken, the gas supply to the pilot light will stop
2
Connects the valve to the receiver
Description
Gas Fire Panorama 110-55
15
Summary of Contents for Panorama 110-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 110 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 110 55...
Page 71: ...9 3 Gas Fire Panorama 110 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 110 55 71...
Page 73: ...9 5 Gas Fire Panorama 110 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 110 55 73...
Page 75: ...9 7 Gas Fire Panorama 110 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 110 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 110 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 110 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 110 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 110 55 83...