1
Non-flammable hearth
2
Convection air inlet
3
Mantel piece
4
Steel studs
5
TV wall mount bracket
6
TV
7
Convection air outlet
8
Concentric flue
9
Non-flammable material
3
10 Air gap and spacers
11 Cable duct
Figure 20. TV installation - surface mounted
A
Minimum 25 cm between mantel piece and top of glass pane
B
Minimum thickness 2.5 cm
C
Minimum 5 cm clearance between bottom of TV and top of mantel piece
D
Minimum 2.5 cm horizontal clearance between front of TV and front of mantel piece
E
Minimum 2.5 cm
F
Minimum thickness 4 cm
G
Minimum 3 mm clearance between appliance and surrounding construction
3
Specifications according the installation instructions of the manufacturer of the concentric flue system
and local regulations.
Clearances
32
Gas Fire Panorama 110-55
Summary of Contents for Panorama 110-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 110 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 110 55...
Page 71: ...9 3 Gas Fire Panorama 110 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 110 55 71...
Page 73: ...9 5 Gas Fire Panorama 110 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 110 55 73...
Page 75: ...9 7 Gas Fire Panorama 110 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 110 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 110 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 110 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 110 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 110 55 83...