background image

Wiring for RS-485 MultiHop Radios

Connecting dc power to the communication pins will cause permanent damage. For FlexPower devices, do not apply more

than 5.5 V to the gray wire. The FlexPower Multihop radios operate equally well when powered from the brown or gray

wire; it is not necessary to supply both. The power for the sensors can be supplied by the radio's SPx terminals or from the

10 to 30 V dc used to power the radio.

Pin

Wire Color

10 to 30 V dc (RS-485)

FlexPower (RS-485)

1

2

3

4

5

1

Brown

10 to 30 V dc

10 to 30 V dc

2

White

RS-485 / D1 / B / +

RS-485 / D1 / B / +

3

Blue

dc common (GND)

dc common (GND)

4

Black

RS-485 / D0 / A / -

RS-485 / D0 / A / -

5

Gray

-

3.6 to 5.5 V dc

Wiring for DX80...M-HxC RS-485 MultiHop Models

Connecting dc power to the communication pins will cause permanent damage. For FlexPower devices, do not apply more

than 5.5 V to the gray wire. The FlexPower Multihop radios operate equally well when powered from the brown or gray

wire; it is not necessary to supply both. The power for the sensors can be supplied by the radio's SPx terminals or from the

10 to 30 V dc used to power the radio.

Terminal

10 to 30 V dc (RS-485)

FlexPower (RS-485)

V+

10 to 30 V dc

10 to 30 V dc

Tx/+

RS-485 / D1 / B / +

RS-485 / D1 / B / +

V-

dc common (GND)

dc common (GND)

Rx/-

RS-485 / D0 / A / -

RS-485 / D0 / A / -

B+

-

3.6 to 5.5 V dc

Wiring for DX80...E Radios

Connecting dc power to the communication pins will cause permanent damage. The integrated battery DX80...E radios

may also be powered by 10 to 30 V dc. The power for the sensors can be supplied by the radio's SPx terminals or from the

10 to 30 V dc used to power the radio.

The BAT connection is a low voltage connection to the internal battery. Remove the internal battery if a low voltage source

is connected to the BAT terminal. When powering the device from the integrated battery, the BAT connection must remain

open.

Integrated battery

(RS-485)

(P1E, M-H1E Models)

Integrated battery (RS-232)

(P3E, P4E, M-H3E, M-H4E Models)

1

2

3

4 BAT

1 10 to 30 V dc (optional)

10 to 30 V dc (optional)

2 RS-485 / D1 / B / +

RS-232 Tx

3 dc common (GND)

dc common (GND)

4 RS-485 / D0 / A / -

RS-232 Rx

Terminal Blocks and Wiring for M-H1* Models

Connecting dc power to the communication pins will cause permanent damage. For the DX8x...C models, PWR in the

wiring diagram refers to V+ on the wiring board and GND in the wiring diagram refers to V- on the wiring board. Do not

exceed analog input ratings for analog inputs. Only connect sensor outputs to analog inputs.

SureCross MultiHop Data Radio

 

 

P/N 148947 Rev. C

www.bannerengineering.com - tel: 763-544-3164

5

Summary of Contents for SureCross DX80DR2M-H1

Page 1: ...y module IP67 NEMA 6 Inputs Four sinking discrete two 0 to 20 mA analog one thermistor one sinking counter Outputs Two NMOS discrete two switch power Serial interface RS 485 DX80DR9M H1E 10 to 30 V dc...

Page 2: ...op Master Radio Within a network of MultiHop data radios there is only one master radio The master radio controls the overall timing of the network and is always the parent device for other MultiHop r...

Page 3: ...duct Manual 151317 MultiHop Register Guide End User Edition 155289 Configure the DIP Switches Before making any changes to the DIP switch positions disconnect the power DIP switch changes will not be...

Page 4: ...ible to enable broadcast acknowledgement of the data packets to provide better throughput In transparent mode there is no access to the radio s I O Baud Rate and Parity The baud rate bits per second i...

Page 5: ...dc 10 to 30 V dc Tx RS 485 D1 B RS 485 D1 B V dc common GND dc common GND Rx RS 485 D0 A RS 485 D0 A B 3 6 to 5 5 V dc Wiring for DX80 E Radios Connecting dc power to the communication pins will cause...

Page 6: ...connection PWR Power 10 to 30 V dc power connection SPx Switch Power Provides variable power sources for external devices Discrete Input Wiring for PNP Sensors Discrete Input Wiring for NPN Sensors D...

Page 7: ...60 Modbus Register Maps Register 4xxxx Input Input Type Units I O Range Holding Register Representation Terminal Block Labels Min Value Max Value Min Dec Max Dec 1 1 Discrete IN 1 0 1 0 1 DI1 2 2 Dis...

Page 8: ...ut 2 output 1 etc Operation type specific parameters discrete counter analog 4 to 20 mA are grouped together based on the I O type number analog 1 analog 2 counter 1 etc Not all inputs or outputs may...

Page 9: ...Remove the four screws mounting the face plate to the housing and remove the face plate Do not remove the radio cover from the face plate 2 Remove the discharged battery and replace with a new battery...

Page 10: ...on covers Weight 0 26 kg 0 57 lbs M Hx and M HxC models Mounting 10 or M5 SS M5 hardware included M HxE models Mounting 1 4 inch or M7 SS M7 hardware included Max Tightening Torque 0 56 N m 5 lbf in I...

Page 11: ...BWA 9O2 C 900 MHz or BWA 2O2 C 2 4 GHz Antenna 2 dBd Omni Rubber Swivel RP SMA Male Not included with Internal antenna models Quick Start Guide 128185 for DX80 Gateways or 152653 for MultiHop models...

Page 12: ...ted Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Banner Engineering Corp will repair or replac...