background image

Datasheet

900 MHz

DX80...E 900 MHz Model

SureCross

®

 MultiHop data radios are wireless industrial communication devices used

to extend the range of a Modbus or other serial communication network.

Wireless industrial I/O device with four sinking discrete inputs, two NMOS

discrete outputs, two analog (0–20 mA) inputs, one thermistor input, one

counter input, and two switch power outputs

Selectable transmit power levels of 250 mW or 1 Watt for 900 MHz models

and 65 mW for 2.4 GHz models

FlexPower

®

 power options allow for 10 to 30 V dc, solar, and battery power

sources for low power applications.

Self-healing, auto-routing RF network with multiple hops extends the

network’s range

Serial and I/O communication on a Modbus platform

Message routing improves link performance

DIP switches select operational modes: master, repeater, or slave

Built-in site survey mode enables rapid assessment of a location’s RF

transmission properties

FHSS radios operate and synchronize automatically

For additional information, updated documentation, and accessories, refer to Banner Engineering's website, 

www.bannerengineering.com/surecross

.

Model

Frequency Power

Housing

I/O

DX80DR9M-H1

900 MHz

ISM Band

10 to 30 V dc or battery

supply module

IP67, NEMA 6

Inputs: Four sinking discrete, two 0 to 20 mA

analog, one thermistor, one sinking counter

Outputs: Two NMOS discrete, two switch

power

Serial interface: RS-485

DX80DR9M-H1E

10 to 30 V dc or integrated

battery

IP54, NEMA 4

DX80DR2M-H1

2.4 GHz

ISM Band

10 to 30 V dc or battery

supply module

IP67, NEMA 6

DX80DR2M-H1E

10 to 30 V dc or integrated

battery

IP54, NEMA 4

DX80...C (IP20; NEMA 1) models are also available. To order this model with an IP20 housing,

add a C to the end of the model number: DX80DR9M-H1C.

Integrated battery models are also available without batteries. If you purchase a model without

the battery, Banner Engineering recommends using the XENO XL-205F battery or equivalent. For

DX99 models, only a XENO XL-205F battery is certified.

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

CAUTION: Never Operate 1 Watt Radios Without Antennas

To avoid damaging the radio circuitry, never power up SureCross Performance or SureCross MultiHop (1

Watt) radios without an antenna.

SureCross MultiHop Data Radio

 

 

P/N 148947 Rev. C

6 January 2014

0 148947

7

Summary of Contents for SureCross DX80DR2M-H1

Page 1: ...y module IP67 NEMA 6 Inputs Four sinking discrete two 0 to 20 mA analog one thermistor one sinking counter Outputs Two NMOS discrete two switch power Serial interface RS 485 DX80DR9M H1E 10 to 30 V dc...

Page 2: ...op Master Radio Within a network of MultiHop data radios there is only one master radio The master radio controls the overall timing of the network and is always the parent device for other MultiHop r...

Page 3: ...duct Manual 151317 MultiHop Register Guide End User Edition 155289 Configure the DIP Switches Before making any changes to the DIP switch positions disconnect the power DIP switch changes will not be...

Page 4: ...ible to enable broadcast acknowledgement of the data packets to provide better throughput In transparent mode there is no access to the radio s I O Baud Rate and Parity The baud rate bits per second i...

Page 5: ...dc 10 to 30 V dc Tx RS 485 D1 B RS 485 D1 B V dc common GND dc common GND Rx RS 485 D0 A RS 485 D0 A B 3 6 to 5 5 V dc Wiring for DX80 E Radios Connecting dc power to the communication pins will cause...

Page 6: ...connection PWR Power 10 to 30 V dc power connection SPx Switch Power Provides variable power sources for external devices Discrete Input Wiring for PNP Sensors Discrete Input Wiring for NPN Sensors D...

Page 7: ...60 Modbus Register Maps Register 4xxxx Input Input Type Units I O Range Holding Register Representation Terminal Block Labels Min Value Max Value Min Dec Max Dec 1 1 Discrete IN 1 0 1 0 1 DI1 2 2 Dis...

Page 8: ...ut 2 output 1 etc Operation type specific parameters discrete counter analog 4 to 20 mA are grouped together based on the I O type number analog 1 analog 2 counter 1 etc Not all inputs or outputs may...

Page 9: ...Remove the four screws mounting the face plate to the housing and remove the face plate Do not remove the radio cover from the face plate 2 Remove the discharged battery and replace with a new battery...

Page 10: ...on covers Weight 0 26 kg 0 57 lbs M Hx and M HxC models Mounting 10 or M5 SS M5 hardware included M HxE models Mounting 1 4 inch or M7 SS M7 hardware included Max Tightening Torque 0 56 N m 5 lbf in I...

Page 11: ...BWA 9O2 C 900 MHz or BWA 2O2 C 2 4 GHz Antenna 2 dBd Omni Rubber Swivel RP SMA Male Not included with Internal antenna models Quick Start Guide 128185 for DX80 Gateways or 152653 for MultiHop models...

Page 12: ...ted Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of shipment Banner Engineering Corp will repair or replac...

Reviews: