Command
Data to LT7
Data from LT7
Meaning
ECM
ACK
Execute
Continuous
Measurement
Set and triggered by the next request for measured values
GDB
Energy value 0 dB to -120 dB
Gain Level
Indicates the amount of received energy
GNR
xxxxxxxxxx
Get Serial Number
Emitted
as ASCII text (maximum 24 characters)
GSI
Bit 7:
transmitter
faulty
Bit 6: receiver blinded or faulty
Bit 5: temperature warning T < -10 °C or T > +70 °C
Bit 4: target out of range or
transmitter
faulty
Bit 3: temperature error T > +85 °C
Bit 2: supply voltage too low
Bit 1: PLL unlocked
Bit 0: not used
Get Error Status
0: no error
1: error
GTE
±xxx
Get Temperature
Internal temperature in °C
GVE
LT7 $Revision x.xx$
Get Version
Software
version is displayed
GCM
All available commands
Help Command/Get Commands
All available commands are displayed in text format
ICM
0,1
ACK
Input
Continuous
Measurement Mode
0:
continuous
measurement output
1: output of single measurement values
IDO
Input desired
value
ACK
Input
Offset
Setting
(All Outputs)
Up to 12000 mm (plus or minus) or 48000 in (plus or minus)4
IVL
0,1
ACK
Enable Visible Laser
0: pilot laser OFF
1: pilot laser ON
ISB
0,1
ACK
Input Stand-by
0:
operation
1: stand-by
ESM
<meas. value>
Trigger/Execute Single Measurement
Request for measured value with single measurement output
EPW
ACK
Write Parameter Page/Execute Parameter Write
Parameters are stored
Discrete Output Q1 Commands and Their Meaning
Command
Data to LT7
Data from LT7
Meaning *
IH1
000.. 254
or
000.. 999
ACK
Set Discrete Q1 Hysteresis
0 mm to 254 mm
or
0 in to 9.99 in
IL1
Input desired limit value (not
including
Offset)
ACK
Input Discrete Q1 Limit 1
0 mm to 12000 mm or 0 in to 480.00 in
Selected
Offset
value is applied to this limit
IL4
Input desired limit value (not
including
Offset)
ACK
Input Discrete Q1 Limit 2
0 mm to 12000 mm or 0 in to 480.00 in
Selected
Offset
value is applied to this limit
4 Do not insert a period or comma. For example 12,000 mm is 12000 mm; 480.00 in is 48000.
L-GAGE
®
LT7 Long-Range Time-of-Flight Laser Sensor
14
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 120244 Rev. C