D12 Expert Series
page
4
Certifications
Supply Voltage and Current
10 to 30V dc at 45 mA max. (exclusive of load); 10% maximum ripple
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
NPN open collector (both outputs) or PNP open collector (both outputs), depending on model;
Load output: N.O. and programmable light- or dark-operate;
Alarm output: N.O.
Output Rating
150 mA maximum each output; the total load may not exceed 150 mA
Off-state leakage current: less than 10 microamps at 30V dc
On-state saturation voltage: less than 1 volt at 10 mA dc and less than 1.5 volts at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and overload of outputs (trips at 175 mA)
Output Response Time
200 microseconds ON and OFF (40 milliseconds OFF when OFF-delay selected)
(NOTE: False pulse protection circuit causes a 0.1 second delay on power-up)
Repeatability
66 microseconds
Adjustments
Push button TEACH mode sensitivity setting; remote teaching input is provided
Indicators
Green LED lights for DC power ON and flashes when ready for TEACH mode; 1 Hz when ready to learn
first condition; 2 Hz for second condition
Yellow LED lights for load output ON (conducting)
7-segment Moving Dot Red LED Display indicates relative received light signal strength, output program
settings, relative contrast level and alarm
Construction
Black ABS (Cycolac
®
KJB) housing with acrylic cover, stainless steel M3 x 0.5 hardware for use with
VALOX
®
mounting bracket (supplied); the plastic fiber clamping element is Delrin
®
Environmental Rating
Rated NEMA 4; IEC IP66
Connections
PVC-jacketed 2 m (6.5') or 9 m (30') cables
Operating Conditions
Temperature: -20° to +70° C (-5° to +158°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Output Operation Mode
Light operate or dark operate; selected by push button
Output Timing Functions
ON/OFF (no delay) or fixed 40 millisecond OFF-delay; selected by push button
D12 Expert Series Specifications
VALOX
®
and Cycolac
®
are registered trademarks of General Electric Co.;
Delrin
®
is a registretd trademark of Dupont
WARNING . . .
Not a Safety Device
These photoelectric sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel
safety applications. A sensor failure or malfunction can result in either an energized or a de-energized sensor output
condition.
Never use these products as sensing devices for personnel protection. Their use as a safety device may create an unsafe condition which
could lead to serious injury or death.
Only MICRO-SCREEN
™
, MINI-SCREEN
®
, MULTI-SCREEN
®
, MACHINE-GUARD
™
and PERIMETER-GUARD
™
Systems, and other systems so
designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner
sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection.
!