Certifications

Supply Voltage and Current

10 to 30V dc at 45 mA max. (exclusive of load); 10% maximum ripple

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

NPN open collector (both outputs) or PNP open collector (both outputs), depending on model; 
Load output: N.O. and programmable light- or dark-operate; 
Alarm output: N.O.

Output Rating

150 mA maximum each output; the total load may not exceed 150 mA 
Off-state leakage current: less than 10 microamps at 30V dc
On-state saturation voltage: less than 1 volt at 10 mA dc and less than 1.5 volts at 150 mA dc

Output Protection Circuitry

Protected against false pulse on power-up and overload of outputs (trips at 175 mA)

Output Response Time

200 microseconds ON and OFF (40 milliseconds OFF when OFF-delay selected)
(NOTE: False pulse protection circuit causes a 0.1 second delay on power-up)

Repeatability

66 microseconds

Adjustments

Push button TEACH mode sensitivity setting; remote teaching input is provided

Indicators

Green LED lights for DC power ON and flashes when ready for TEACH mode; 1 Hz when ready to learn
first condition; 2 Hz for second condition
Yellow LED lights for load output ON (conducting)
7-segment Moving Dot Red LED Display indicates relative received light signal strength, output program
settings, relative contrast level and alarm

Construction

Black ABS (Cycolac

®

KJB) housing with acrylic cover, stainless steel M3 x 0.5 hardware for use with

VALOX

®

mounting bracket (supplied); the plastic fiber clamping element is Delrin

®

Environmental Rating

Rated NEMA 4; IEC IP66

Connections

PVC-jacketed 2 m (6.5') or 9 m (30') cables

Operating Conditions

Temperature: -20° to +70° C (-5° to +158°F)

Maximum relative humidity: 90% at 50°C (non-condensing)

Output Operation Mode

Light operate or dark operate; selected by push button

Output Timing Functions

ON/OFF (no delay) or fixed 40 millisecond OFF-delay; selected by push button

D12 Expert Series Specifications

VALOX

®

and Cycolac

® 

are registered trademarks of General Electric Co.; 

Delrin

®

is a registretd trademark of Dupont

WARNING . . .

Not a Safety Device

These photoelectric sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel
safety applications. A sensor failure or malfunction can result in either an energized or a de-energized sensor output
condition.

Never use these products as sensing devices for personnel protection. Their use as a safety device may create an unsafe condition which
could lead to serious injury or death.

Only MICRO-SCREEN

, MINI-SCREEN

®

, MULTI-SCREEN

®

, MACHINE-GUARD

and PERIMETER-GUARD

Systems, and other systems so

designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner
sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel protection.

!

Summary of Contents for Expert D12 Series

Page 1: ...E2P6FP PNP sourcing IMPORTANT SEE SAFETY USE WARNING ON PAGE 4 D12 Expert Features Fiber optic sensors for DIN rail mounting 10 to 30V dc operation Visible red 680 nm light source models for use with...

Page 2: ...ming Modes TEACH Mode All photoelectric sensing applications excluding analog response applications involve differentiating between two received light levels The condition with the higher received lig...

Page 3: ...dels were first developed to ignore a small amount of web flutter in high speed registration color mark sensing applications At the end of the TEACH mode process the D12 Expert bargraph indicator flas...

Page 4: ...ontrast level and alarm Construction Black ABS Cycolac KJB housing with acrylic cover stainless steel M3 x 0 5 hardware for use with VALOX mounting bracket supplied the plastic fiber clamping element...

Page 5: ...Slide the fiber gripper up open For 010 or 020 dia fibers insert the small fiber adaptor into the ports as far as it will go B Insert the prepared plastic fiber sensor ends gently into the ports as fa...

Page 6: ...maximum sensitivity Use the following TEACH mode procedure at any time to return the sensitivity to its maximum setting Following the TEACH mode procedure on page 8 teach the following two conditions...

Page 7: ...nger Output settings are displayed Two steady red LEDs indicate the output settings light or dark operate and output timing 0 or 40ms NOTE The sensor continues to operate normally during the display p...

Page 8: ...l automatically return to RUN mode if the push button is not clicked within 10 seconds Double click ON indicator green LED single flashes at 1 Hz Green ON LED single flashes at 1Hz and the 7 segment d...

Page 9: ...ansistor The timing diagrams Figure 5 below define single double and triple click simulating the D12 Expert s programming push button The ON time of each click must be at least 40 milliseconds The min...

Page 10: ...n RUN mode with the most recent settings Display LEDs 1 and 7 flash together 6 times Figure 8 Problem This occurs at the end of TEACH mode when the sensor has received faulty data Faulty data may resu...

Page 11: ...For a complete selection of fibers in these sizes and for more information see your current Banner Photoelectric Sensors Catalog Qty Required for Each Unit 2 2 2 1 0 7 mm 027 individual pair IMM 443S...

Page 12: ...ge OPPOSED MODE 0 5 mm 02 bifurcated PBT26U 0 5 mm 02 individual pair PIT26U 84 mm 3 3 1 0 mm 04 individual pair PIT46U 315 mm 12 4 1 5 mm 06 individual pair PIT66U 660 mm 26 0 25 mm 1 0 1 0 mm 04 bif...

Reviews: