background image

D12 Expert Series

page 

5

D12 Expert Dimensions

D12 Expert Series – Glass Fiber Optic Models

20.2 mm

(0.79")

35.5 mm

(1.40")

Fiber-retaining Clip
(Supplied with Sensor)

7-Segment Display

Output Indicator

Power Indicator

Push Button

Pull to Relase
Bracket

5.0 mm
(0.20")

Glass Fiber Receiver Port

Glass Fiber Emitter Port

Mounting Bracket

(Included)

12.0 mm

(0.47")

30.0 mm

(1.18")

64.4 mm

(2.52")

D12 Expert Series – Plastic Fiber Optic Models

20.2 mm

(0.79")

35.5 mm

(1.40")

Fiber Gripper – 
Slide Up
to Install or 
Release Fibers

7-Segment Display

Output Indicator

Power Indicator

Push Button

Pull to Relase
Bracket

5.0 mm
(0.20")

Plastic Fiber Receiver Port

Plastic Fiber Emitter Port

Mounting Bracket

(Included)

Small Fiber

Adapter

12.0 mm

(0.47")

30.0 mm

(1.18")

64.4 mm

(2.52")

Plastic Fiber Installation:

A. Cut fiber ends per instructions

included with the fibers. Slide the
fiber gripper up (open). (For .010" 
or .020" dia. fibers, insert the small
fiber adaptor into the ports as far as
it will go.)

B. Insert the prepared plastic fiber

sensor ends gently into the ports as
far as they will go.

C. Slide the fiber gripper back down to

lock.

Glass Fiber Installation:

A. Slide the sensor ends of the fiber(s)

into the D12 Expert fiber ports as far
as they will go.

B. Push firmly on the fiber ends to

compress the o-rings (supplied with
the fibers) and to align the grooves
in the fiber ends with the slot above
the emitter port. Slide the retaining
clip into the slot and press the clip
until it snaps into the grooves.

Mounting Bracket

D12E Sensors mount directly to a standard 35mm DIN rail, or may be through-hole
mounted using the supplied mounting bracket and M3 x 0.5 hardware.

Section A-A

A

A

2.5 mm

(0.10")

2.3 mm

(0.09")

24.5 mm

(1.00")

4.8 mm

(0.19")

ø 3.25 mm (2)

(0.128")

8.6 mm

(0.34")

11.9 mm

(0.47")

0.94 mm
(0.037")

3.45 mm (2)
(0.136")

15.2 mm

(0.60")

35.0 mm

(1.38")

9.9 mm

(0.39")

ø 4.45 mm (2)

(0.175")

ø 7.9 mm x 3.0 mm 

deep (2)

(0.31" x 0.12")

Summary of Contents for Expert D12 Series

Page 1: ...E2P6FP PNP sourcing IMPORTANT SEE SAFETY USE WARNING ON PAGE 4 D12 Expert Features Fiber optic sensors for DIN rail mounting 10 to 30V dc operation Visible red 680 nm light source models for use with...

Page 2: ...ming Modes TEACH Mode All photoelectric sensing applications excluding analog response applications involve differentiating between two received light levels The condition with the higher received lig...

Page 3: ...dels were first developed to ignore a small amount of web flutter in high speed registration color mark sensing applications At the end of the TEACH mode process the D12 Expert bargraph indicator flas...

Page 4: ...ontrast level and alarm Construction Black ABS Cycolac KJB housing with acrylic cover stainless steel M3 x 0 5 hardware for use with VALOX mounting bracket supplied the plastic fiber clamping element...

Page 5: ...Slide the fiber gripper up open For 010 or 020 dia fibers insert the small fiber adaptor into the ports as far as it will go B Insert the prepared plastic fiber sensor ends gently into the ports as fa...

Page 6: ...maximum sensitivity Use the following TEACH mode procedure at any time to return the sensitivity to its maximum setting Following the TEACH mode procedure on page 8 teach the following two conditions...

Page 7: ...nger Output settings are displayed Two steady red LEDs indicate the output settings light or dark operate and output timing 0 or 40ms NOTE The sensor continues to operate normally during the display p...

Page 8: ...l automatically return to RUN mode if the push button is not clicked within 10 seconds Double click ON indicator green LED single flashes at 1 Hz Green ON LED single flashes at 1Hz and the 7 segment d...

Page 9: ...ansistor The timing diagrams Figure 5 below define single double and triple click simulating the D12 Expert s programming push button The ON time of each click must be at least 40 milliseconds The min...

Page 10: ...n RUN mode with the most recent settings Display LEDs 1 and 7 flash together 6 times Figure 8 Problem This occurs at the end of TEACH mode when the sensor has received faulty data Faulty data may resu...

Page 11: ...For a complete selection of fibers in these sizes and for more information see your current Banner Photoelectric Sensors Catalog Qty Required for Each Unit 2 2 2 1 0 7 mm 027 individual pair IMM 443S...

Page 12: ...ge OPPOSED MODE 0 5 mm 02 bifurcated PBT26U 0 5 mm 02 individual pair PIT26U 84 mm 3 3 1 0 mm 04 individual pair PIT46U 315 mm 12 4 1 5 mm 06 individual pair PIT66U 660 mm 26 0 25 mm 1 0 1 0 mm 04 bif...