D12 Expert Series

page 

7

Output Configuration Programming

Programming is performed using the push button and a combination of single-,
double-, and triple-clicks. (For a description of these clicks, see Remote Programming
on page 9). Two output functions may be programmed by the push button:

1. Either no delay or a fixed 40 millisecond pulse stretcher (OFF-delay) for loads (or

circuit inputs) that are too slow to react to a quick event. With no OFF-delay,
sensing response is a fast 200 microseconds (.0002 seconds), both ON and OFF.

2. The output may be programmed for either light operate (LO) or dark operate

(DO).  In light operate, the sensor load output is energized during the light
condition; in dark operate the load output is energized during the dark condition.

These two output functions are programmed in sequence – first the output timing,
followed by the light/dark operate selection – as explained in the chart. The factory
settings are 0 millisecond OFF-delay (no delay) and light operate (LO). To check the
output configuration at any time, hold down the push button for 2 seconds. The
sensor’s 7-segment LED display will indicate the setting for 10 seconds, while the
sensor continues normal operation. 

NOTE: To escape from PROGRAM mode and return to RUN mode at any point, push

and hold the push button for 2 seconds.

Push button

Indicator Status

Push and hold 2 seconds or longer

Output settings are displayed

Two steady red LEDs indicate the output settings:
light or dark operate and output timing (0 or 40ms).

NOTE: The sensor continues to operate normally

during the display period. The display will
automatically return to RUN mode if the push
button is not clicked within 10 seconds.

Triple-click

Output timing selection is displayed

Red LED flashes at 1Hz opposite either     
0 ms or 40 ms output timing

NOTE: The sensor will return to RUN mode if the

push button is not clicked within 90 seconds.

Double-click

Output timing is stored and the LO or
DO selection is displayed

Red LED flashes at 1 Hz opposite either 
LO or DO output mode

NOTE:  The sensor will return to RUN mode if the

push button is not clicked within 90 seconds.

Double-click

LO/DO choice is stored and the
sensor returns to RUN mode.

The 7-segment LED bar graph indicates relative
received signal strength.

Mode

Change to

OUTPUT

CONFIGURATION

(PROGRAM)

mode

Output timing 

selection

Continue in

OUTPUT

CONFIGURATION

(PROGRAM)

mode

Light/dark operate

selection

Return to

RUN mode

Change from 

RUN mode to 

OUTPUT

CONFIGURATION

(DISPLAY) mode

Push and Hold

 2 Seconds

Single-click to toggle between 0 ms 
and 40 ms

Flashing red LED toggles between 
0 ms (no delay) and 40 ms (off-delay)

Flashing red LED toggles between 
LO  and DO

Single-click to toggle between LO
and DO

Triple-Click

Double-Click

Double-Click

ON

7

6

5

4

3

2

1

ALM

LO

DO

40 ms

0 ms

Light/Dark 

Operate Indicators

0 or 40 ms Pulse 

Stretcher Indicators

Figure 3. D12 Expert setting indicators,

shown set to factory defaults

Summary of Contents for Expert D12 Series

Page 1: ...E2P6FP PNP sourcing IMPORTANT SEE SAFETY USE WARNING ON PAGE 4 D12 Expert Features Fiber optic sensors for DIN rail mounting 10 to 30V dc operation Visible red 680 nm light source models for use with...

Page 2: ...ming Modes TEACH Mode All photoelectric sensing applications excluding analog response applications involve differentiating between two received light levels The condition with the higher received lig...

Page 3: ...dels were first developed to ignore a small amount of web flutter in high speed registration color mark sensing applications At the end of the TEACH mode process the D12 Expert bargraph indicator flas...

Page 4: ...ontrast level and alarm Construction Black ABS Cycolac KJB housing with acrylic cover stainless steel M3 x 0 5 hardware for use with VALOX mounting bracket supplied the plastic fiber clamping element...

Page 5: ...Slide the fiber gripper up open For 010 or 020 dia fibers insert the small fiber adaptor into the ports as far as it will go B Insert the prepared plastic fiber sensor ends gently into the ports as fa...

Page 6: ...maximum sensitivity Use the following TEACH mode procedure at any time to return the sensitivity to its maximum setting Following the TEACH mode procedure on page 8 teach the following two conditions...

Page 7: ...nger Output settings are displayed Two steady red LEDs indicate the output settings light or dark operate and output timing 0 or 40ms NOTE The sensor continues to operate normally during the display p...

Page 8: ...l automatically return to RUN mode if the push button is not clicked within 10 seconds Double click ON indicator green LED single flashes at 1 Hz Green ON LED single flashes at 1Hz and the 7 segment d...

Page 9: ...ansistor The timing diagrams Figure 5 below define single double and triple click simulating the D12 Expert s programming push button The ON time of each click must be at least 40 milliseconds The min...

Page 10: ...n RUN mode with the most recent settings Display LEDs 1 and 7 flash together 6 times Figure 8 Problem This occurs at the end of TEACH mode when the sensor has received faulty data Faulty data may resu...

Page 11: ...For a complete selection of fibers in these sizes and for more information see your current Banner Photoelectric Sensors Catalog Qty Required for Each Unit 2 2 2 1 0 7 mm 027 individual pair IMM 443S...

Page 12: ...ge OPPOSED MODE 0 5 mm 02 bifurcated PBT26U 0 5 mm 02 individual pair PIT26U 84 mm 3 3 1 0 mm 04 individual pair PIT46U 315 mm 12 4 1 5 mm 06 individual pair PIT66U 660 mm 26 0 25 mm 1 0 1 0 mm 04 bif...

Reviews: