D12 Expert Series
page
11
Glass Fiber Assembly
Fiber Diameter
Typical Fiber
Model
Maximum Range*
OPPOSED MODE
1.2 mm (.046") individual pair**
IM.753S
295 mm (11.6")
1.6 mm (.062") individual pair**
IT13S
442 mm (17.4")
3.2 mm (.125") individual pair**
IT23S
930 mm (36.6")
DIFFUSE MODE (Based on a 90% reflectance white test card)
0.7 mm (.027") bifurcated
BMM.443P
15 mm (0.6")
The following charts list all the fiber sizes that can be used with these sensors. Typical
fiber models (one for each size and type) are indicated, along with the maximum
range for each (expect less range for fiber assemblies with angled sensing ends). For
a complete selection of fibers in these sizes and for more information see your
current Banner Photoelectric Sensors Catalog.
Qty. Required
for Each Unit
2
2
2
1
0.7 mm (.027") individual pair**
IMM.443S
107 mm (4.2")
2
1.2 mm (.046") bifurcated
BM.753S
46 mm (1.8")
1.6 mm (.062") bifurcated
BT13S
68 mm (2.7")
1
1
3.2 mm (.125") bifurcated
BT23S
178 mm (7.0")
1
Sensing Tip
(Dimensions in Inches)
.027 dia.
bundle
.18
.043
.50
.50
1.00
±
.030
.29
Bundle
Diameter
.18
.060
.50
.50
1.0
±
.030
.29
Bundle
Diameter
5/16 x 24 Thd Brass
2 Jam Nuts included
.50
.31
1.5
.027 dia.
bundle
.18
.043
.50
.50
1.00
±
.030
.29
Bundle
Diameter
.18
.060
.50
.50
1.0
±
.030
.29
Bundle
Diameter
5/16 x 24 Thd Brass
2 Jam Nuts included
.50
.31
1.5
Accessories
*
Range data is for 0.9 m (3') glass fiber assemblies
** Glass fibers are used in pairs, sold individually – two are required