RF Ctrl
—Displays the status of the ISM radio DIP switch 1 (off or on). The menu doesn't allow the user to change the DIP
switch setting through the display.
Ethernet
Use the Ethernet submenu to sets the IP Address, Gateway Address, and Subnet mask of the DXM Controller's Ethernet
interface. You may change these settings either from the LCD menu (System Config
›
Ethernet) or from the XML
configuration file created by the DXM Configuration Software.
The network address settings from the LCD menu have the highest priority and override settings in the XML configuration file.
To use the parameter settings from the XML configuration file or use DHCP, execute the Reset under System
Config
›
Ethernet or use the LCD to set the IP Address, Gateway Address, and Subnet Mask to 255.255.255.255. Reboot the
DXM Controller after changing the Ethernet parameters.
The Ethernet cable should be attached before powering up the DXM Controller.
LCD Contrast
Use the LCD Contrast option to adjust the LCD contrast. Adjust the starting number lower to decrease the display contrast.
The factory default is 28. Do not set a number less than 15 or the display may not be bright enough to see to change back.
Reset
Use the Restart menu to force the main processor to restart. This does not affect the other boards in the system.
System Info
Various DXM system settings are shown in this menu. The Push, Ethernet, and Cell parameters are helpful for debugging
network connections. This is a read-only menu.
System Info menu
System Info
Controller
Push
ISM Radio
Date:
Firmware:
Build:
Model:
Serial:
Method:
Interval: hh:mm
URL:
Page:
Https: on/off
Site ID:
Serial:
Model:
Date:
RF FW Pt:
RF FW Ver:
RF EE Pt:
RF EE Ver:
to change the value
to accept
ENTER
BACK
to return to the previous menu
↑
↓
Ethernet
DHCP:
IP:
Subnet:
Gate:
Mac:
DNS1:
DNS2:
Cell
Signal:
Phn#:
Dev#:
SIM:
CellVer:
CellMdl:
CellFw:
CellMask:
Wifi
IP:
Mode:
AP:
Stat:
Script
Path:
Baud:
Code:
LCD Board
Serial:
Model:
Date:
RF FW Pt:
RF FW Ver:
RF EE Pt:
RF EE Ver:
Cell
Shows the cellular MEID number (Mobil Equipment Identifier),
MDN (Mobil Device Number), version, signal, firewall setting,
and firewall mask. Some of these parameters are not visible
until the cellular network is accessed.
Summary of Contents for DXM1200-X2
Page 4: ...4 Warnings 81 Banner Engineering Corp Limited Warranty 82 Document Information 82...
Page 20: ...20...
Page 28: ...28...
Page 36: ...36...
Page 44: ...44...
Page 62: ...62...
Page 70: ...70...
Page 72: ...72...
Page 83: ...LinkedIn Twitter Facebook 2024 All rights reserved www bannerengineering com...