background image

Discrete Input Wiring for PNP Sensors

Discrete Input Wiring for NPN Sensors

DIx

PWR

10-30V dc

DIx

GND

dc common

Wiring Diagrams for Discrete Outputs

Connecting dc power to the communication pins will cause permanent damage. For the DX8x...C models, PWR in the wiring diagram refers to V+ on the wiring board and
GND in the wiring diagram refers to V- on the wiring board.

Discrete Output Wiring (PNP)

DOx

GND

PWR

10-30V dc

Load

dc common

Wiring Diagrams for Analog Inputs

Connecting dc power to the communication pins will cause permanent damage. Do not exceed analog input ratings for analog inputs. Only connect sensor outputs to
analog inputs.

Analog Input Wiring (10 to 30V dc Power)

Analog Input Wiring (4–20mA, 2-Wire, Externally
Powered Sensors)

Analog Input Wiring (4–20mA, 2-Wire, Switch Pow-
ered Sensors)

AIx

PWR

10-30V dc

GND

+

sensor

dc common

AIx

GND

dc common

external power

+

sensor

+

AIx

SPx

GND

+

sensor

dc common

(Only possible in models with switch power (SPx) out-
puts)

Wiring Diagrams for Analog Outputs

Connecting dc power to the communication pins will cause permanent damage. Do not exceed analog input ratings for analog inputs. Only connect sensor outputs to
analog inputs.

Analog Output Wiring

AOx

GND

dc common

PWR

10-30V dc

sensor

LED Behavior for the Gateways

After powering up and binding the Gateway and its Nodes, verify all devices are communicating properly. When testing communication between the Gateway and Node, all
radios and antennas should be at least two meters apart or the communications may fail. This table lists the LED behavior for the Gateway models with two LEDs.

LED 1

LED 2

Gateway Status

 (solid green)

Power ON

 (flashing red)

 (flashing red)

Device Error

SureCross Performance Gateway

 

 

P/N 155861 Rev. D

www.bannerengineering.com - tel: 763-544-3164

5

Summary of Contents for DX80G9M6S-P2

Page 1: ...arameters when a host system is not part of the wireless network The UCT requires a special USB to RS 485 model number BWA UCT 900 for 1 Watt radios BWA HW 006 can be used for all other radios converter cable to pass information between your comput er and the Gateway Download the most recent revisions of the UCT software from Banner Engi neering s website http www bannerengineering com wireless Se...

Page 2: ...h Settings Switches Device Settings 1 2 3 4 5 6 7 8 900 MHz transmit power level 1 Watt 30 dBm OFF 900 MHz transmit power level 250 mW 24 dBm DX80 com patibility mode ON Modbus or UCT configured overrides DIP switches 3 8 OFF DIP switch configured ON Inputs sourcing PNP OFF Inputs sinking NPN ON Link loss output zero OFF OFF Link loss output one OFF ON Link loss output hold last state ON OFF Link ...

Page 3: ...m you have selected the correct resistor to cut Step 2 Launch the User Configuration Tool software Step 3 Change the units parameter for this particular input on this device Gateway or Node to use voltage instead of milliamps Refer to the Modbus Register table for the I O number for each analog input Writing a four 4 to the Units parameter defines the units as 0 to 10V Writ ing a two 2 to the Unit...

Page 4: ...0 A B 3 6 to 5 5V dc Connecting dc power to the communication pins will cause permanent damage For FlexPower devices do not apply more than 5 5V to the gray wire Terminal Block IP20 This is the terminal block for the DX80 M6S P2C models G B W DO4 TX RX DO3 V AO2 AO1 DO2 DO1 DI2 DI1 AI2 AI1 V V V DI3 DI4 A1 A2 AIx or Ax Analog IN x AOx Analog OUT x DIx Discrete IN x DOx Discrete OUT x GND Ground dc...

Page 5: ... Pow ered Sensors AIx PWR 10 30V dc GND sensor dc common AIx GND dc common external power sensor AIx SPx GND sensor dc common Only possible in models with switch power SPx out puts Wiring Diagrams for Analog Outputs Connecting dc power to the communication pins will cause permanent damage Do not exceed analog input ratings for analog inputs Only connect sensor outputs to analog inputs Analog Outpu...

Page 6: ...Analog OUT 1 mA 0 0 20 0 0 65535 AO1 14 14 14 Node 16 Analog OUT 2 mA 0 0 20 0 0 65535 AO2 15 15 15 Node 16 Control Message 16 16 16 Node 16 Reserved Specifications Radio General Radio Range 900 MHz 1 Watt Up to 9 6 kilometers 6 miles 2 4 GHz Up to 3 2 kilometers 2 miles Radio Transmit Power 900 MHz 1 Watt 30 dBm conducted up to 36 dBm EIRP 2 4 GHz 18 dBm conducted less than or equal to 20 dBm EIR...

Page 7: ...erproofing instructions Operating the devices at the maximum operating conditions for extended periods can shorten the life of the de vice Ratings Rating for DX80 models IEC IP67 NEMA 6 See UL section below for any applicable UL specifications Rating for DX80 C models IEC IP20 NEMA 1 Operating Temperature 40 to 85 C Electronics 20 to 80 C LCD Operating Humidity 95 max relative non condensing Radia...

Page 8: ...ESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSE QUENTIAL OR SP...

Reviews: