Technical data
Panel PC 2100 user's manual V1.17
41
2.2.2.3 Vibration
The following table provides an overview of the maximum vibration values of the complete system. Limitations are
possible through the use of individual components.
Panel PC
Operation
1)
Storage
1)2)
Transport
1)2)
Continuous
Periodic
With CFast card
2 to 9 Hz:
1.75 mm amplitude
9 to 200 Hz: 0.5 g
2 to 9 Hz:
3.5 mm amplitude
9 to 200 Hz: 1 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
Table 29: Vibration
1)
Testing is performed in accordance with EN 60068-2-6.
2)
This value applies to a device in its original packaging.
2.2.2.4 Shock
The following table provides an overview of the maximum shock values of the complete system. Limitations are
possible through the use of individual components.
Panel PC
Operation
1)
Storage
1)2)
Transport
1)2)
With CFast card
15 g, 11 ms
30 g, 6 ms
30 g, 6 ms
Table 30: Shock
1)
Testing is performed in accordance with EN 60068-2-27.
2)
This value applies to a device in its original packaging.
2.2.2.5 Protection
The Panel PC 2100 has IP65 protection on the front and IP20 protection on the back per EN 60529 under the
following conditions:
•
The Panel PC 2100 is installed correctly (see
•
All covers or components are installed on the interfaces and slots.
•
All environmental conditions are being observed.
The Panel PC 2100 with AP9x3 and AP1000 panels also has "Type 4X indoor use only" protection on the front
per UL 50 under the same conditions.