background image

 General information

Panel PC 2200 built-in devices User's manual V 1.05 Translation of the original documentation

7

1 General information

Information:

This document is not intended for end customers! The safety guidelines required for end customers

must be incorporated into the operating instructions for end customers in the respective national lan-

guage by the machine manufacturer or system provider.

1.1 Manual history

Version

Date

Change

1.00

November 2018

First version

1.05

December 2018

Updated document.

Summary of Contents for 2200 Series

Page 1: ...ce B R Industrial Automation GmbH is not liable for technical or editorial errors and defects in this manual In addition B R Industrial Automation GmbH assumes no liability for damages that are direct...

Page 2: ...2 2 Technical data 14 2 1 Introduction 14 2 1 1 Information about this user s manual 14 2 1 2 Description of individual modules 14 2 1 2 1 AP9x3 panels 14 2 1 2 2 AP1000 panels 14 2 1 2 3 System units...

Page 3: ...3 2 AP1000 panels 89 2 3 2 1 5AP1120 0573 000 89 2 3 2 2 5AP1151 0573 000 92 2 3 2 3 5AP1120 0702 000 95 2 3 2 4 5AP1130 0702 000 97 2 3 2 5 5AP1120 101E 000 99 2 3 2 6 5AP1130 101E 000 101 2 3 2 7 5...

Page 4: ...4 1 General information before switching on the device 221 3 4 2 Switching on the device 221 3 5 General instructions for the temperature test procedure 222 3 5 1 Procedure 222 3 5 2 Evaluating tempe...

Page 5: ...2 4 5 2 Order data 262 4 5 3 Overview 262 4 5 4 Features 262 4 5 5 Installation 262 4 5 6 Drivers 263 4 6 B R Automation Device Interface ADI Control Center 264 4 6 1 Functions 264 4 6 2 Installation...

Page 6: ...can the service life of backlights be extended 284 7 2 2 Image persistence 284 7 2 2 1 What causes image persistence 284 7 2 2 2 How can image persistence be reduced 284 7 3 Pixel errors 284 7 4 Repl...

Page 7: ...document is not intended for end customers The safety guidelines required for end customers must be incorporated into the operating instructions for end customers in the respective national lan guage...

Page 8: ...for proper ESD handling Electrical assemblies with housing Do not touch the connector contacts of connected cables Do not touch the contact tips on circuit boards Electrical assemblies without housing...

Page 9: ...relevant regulations e g wire cross sec tion fuse protection protective ground connection 1 2 6 Operation 1 2 6 1 Protection against contact with electrical parts In order to operate programmable log...

Page 10: ...secure plants systems machines and networks against cyber threats it is required to implement and contin uously maintain a holistic security concept that is state of the art B R products and solutions...

Page 11: ...inor injury or damage to property Notice Failure to observe these safety guidelines and notices can result damage to property Table 2 Organization of safety notices General notices Contain useful info...

Page 12: ...ble with 5PP520 0702 00 95 5AP1120 101E 000 Automation Panel 10 1 WXGA TFT 1280 x 800 pixels 16 10 Single touch analog resistive Control cabinet installation Landscape format For PPC2100 PPC3100 PPC22...

Page 13: ...h analog resistive Control cabinet installation Landscape format For PPC900 PPC2100 PPC3100 PPC2200 For link modules 74 5AP933 156B 00 Automation Panel 15 6 HD TFT 1366 x 768 pixels 16 9 Multi touch p...

Page 14: ...plete system in combination with a link module Automation Panel 9x3 or CPU board and system unit Panel PC 900 Panel PC 2100 Panel PC 2200 Panel PC 3100 The panels are installed using retaining clips S...

Page 15: ...be connected The main memory modules are permanently installed on the system unit and cannot be replaced If a system unit is installed on a panel this results in a functional Panel PC 2200 A system un...

Page 16: ...ouch No Landscape 5AP1120 121E 000 12 1 WXGA Single touch No Landscape 5AP1120 1505 000 15 0 XGA Single touch No Landscape 5AP1120 156B 000 15 6 HD Single touch No Landscape 5AP1120 1906 000 19 0 SXGA...

Page 17: ...1 FPSC 000 5ACCIF01 FPCS 000 5ACCIF01 ICAN 000 5ACCIF01 FPLK 000 5ACCIF01 FPLS 001 5ACCIF01 FPSC 001 5ACCIF03 CETH 000 Accessories Optional selection 5MMUSB 2048 01 5MMUSB 4096 01 5MMUSB 032G 02 Termi...

Page 18: ...23 1505 00 370 288 357 84 5 9 275 14 5 13 5 19 0 single touch 5AP923 1906 00 440 358 427 149 9 345 23 13 5 15 6 multi touch 5AP933 156B 00 414 258 5 401 105 5 9 245 5 20 13 5 18 5 multi touch 5AP933 1...

Page 19: ...5 10 1 multi touch 5AP1130 101E 000 279 191 266 38 9 178 18 13 5 10 4 single touch 5AP1120 1043 000 323 260 300 47 2 5 7 240 21 16 10 4 single touch with keys 5AP1180 1043 000 323 260 300 47 2 5 7 24...

Page 20: ...17 5 268 400 12 1 single touch 5AP1120 1214 000 362 284 309 52 5 5 7 234 20 3 17 5 264 339 15 0 single touch 5AP1120 1505 000 435 330 382 81 5 5 7 280 24 3 24 310 412 15 0 single touch with keys 5AP11...

Page 21: ...Model number X Y Z min Z max Number of retaining clips 12 1 single touch 5AP923 1215 00 304 228 1 6 10 pcs 15 0 single touch 5AP923 1505 00 359 277 1 6 10 pcs 19 0 single touch 5AP923 1906 00 429 347...

Page 22: ...ulti touch 5AP1130 101E 000 268 180 1 6 8 10 4 single touch 5AP1120 1043 000 303 243 1 10 8 10 4 single touch with keys 5AP1180 1043 000 303 243 1 10 8 12 1 single touch 5AP1120 121E 000 313 210 5 1 6...

Page 23: ...3 341 2 10 10 10 4 single touch with keys 5AP1182 1043 000 403 271 2 10 8 12 1 single touch 5AP1120 1214 000 342 267 2 10 8 15 0 single touch 5AP1120 1505 000 415 313 2 10 8 15 0 single touch with key...

Page 24: ...g instal lation The air inlet and air outlet are shown in the following figure Because the warm air rises from bottom to top the air inlet is at the bottom Air inlet Air outlet S4 Rear view Side view...

Page 25: ...e 8 Panel PC 2200 Mounting orientation Mounting orientation Ambient temperature limitation1 0 0 None A 1 to 90 counterclockwise 5 C B 1 to 90 clockwise 5 C C D 180 interfaces on top None C 1 to 90 5 C...

Page 26: ...uch with keys 5AP1180 1043 000 2800 10 4 single touch with keys 5AP1181 1043 000 3400 10 4 single touch with keys 5AP1182 1043 000 3500 12 1 single touch 5AP1120 1214 000 3200 12 1 single touch 5AP112...

Page 27: ...2 2 1 1 Maximum ambient temperature for worst case operation All temperature specifications in degrees Celsius C at 500 m above sea level non condensing Maximum worst case ambient temperature system...

Page 28: ...P933 215C 00 C0 0 0 0 0 5AP933 215C 00 D0 0 0 0 0 5AP933 240C 00 C0 0 0 0 0 AP9x3 panels 5AP933 240C 00 D0 10 10 10 10 5AP1120 0573 000 10 10 10 10 5AP1151 0573 000 0 0 0 0 5AP1120 0702 000 20 20 20 2...

Page 29: ...60 55 55 Maximum ambient temperature for typical operation accessories 5AP923 1215 00 5AP923 1505 00 5AP923 1906 00 D0 50 50 50 50 5AP923 1906 00 E0 5AP933 156B 00 C0 50 50 50 50 5AP933 156B 00 D0 5A...

Page 30: ...options and CFast cards are additionally installed in the PPC2200 system they may result in a temperature limitation 4 Possible limitations may arise due to the mounting orientation of the Panel PC 2...

Page 31: ...000 25 to 70 C 25 to 70 C 10 4 single touch with keys 5AP1181 1043 000 25 to 70 C 25 to 70 C 10 4 single touch with keys 5AP1182 1043 000 25 to 70 C 25 to 70 C 12 1 single touch 5AP1120 1214 000 25 to...

Page 32: ...B R PVI ADI line2 B R ADI SNMP Agent2 Automation Runtime library2 In addition the CFast cards available from B R for xPC2200 systems are equipped with Self Monitoring Analysis and Reporting Technology...

Page 33: ...0573 000 80 C 5AP1151 0573 000 80 C 5AP1120 0702 000 85 C 5AP1130 0702 000 85 C 5AP1120 101E 000 80 C 5AP1130 101E 000 80 C 5AP1120 1043 000 90 C 5AP1180 1043 000 90 C 5AP1181 1043 000 90 C 5AP1182 1...

Page 34: ...single touch 5AP1120 121E 000 5 to 90 5 to 90 5 to 90 12 1 multi touch 5AP1130 121E 000 5 to 90 5 to 90 5 to 90 15 0 single touch 5AP1120 1505 000 8 to 90 8 to 90 8 to 90 15 0 single touch with keys...

Page 35: ...in its original packaging 2 2 2 4 Shock The following table provides an overview of the maximum shock values of the complete system Limitations are possible due to individual components Panel PC Opera...

Page 36: ...ce is not damaged if the supply voltage is overloaded fuse must be replaced or connected incorrectly reverse polarity protection fuse replacement not necessary If the fuse is destroyed during a fault...

Page 37: ...W 21 5 multi touch 5AP933 215C 00 C0 7 4 W 18 3 W 25 7 W 21 5 multi touch 5AP933 215C 00 D0 4 W 15 W 19 W 24 0 multi touch 5AP933 240C 00 C0 6 35 W 24 W 30 35 W 24 0 multi touch 5AP933 240C 00 C0 5 W...

Page 38: ...W 2 W Table 36 Interface options Power calculation The following specifications are maximum values CFast cards Model number 5 V 3V3 12 V Total power consumption CFast cards with SLC technology 5CFAST...

Page 39: ...st USB UPS Connector USB interface 7 optional TPM2 0 BIOS Mini PCIe connector Interface option PCIe 2 PCIe 5 USB interface 3 eDP2LVDS LVDS DDC_I2C eDP Display connector USB interface 2 Figure 10 Syste...

Page 40: ...option PCIe 2 Power down IF option POWERLINK RS232 nvSRAM POWERLINK RS232 Connector 10 pin F_I0 Green Green Red LED L2 LED L3 nvSRAM FPGA Figure 15 POWERLINK RS232 nvSRAM IF option 5ACCIF01 FPLS 001...

Page 41: ...1 ICAN 000 Block diagram Mini PCIe connector Interface option PCIe 2 Power down IF option 2x RS422 RS485 Connector 10 pin Yellow LED L2 Terminating resistor Insulator Yellow LED L3 RS422 RS485 Insulat...

Page 42: ...uct family power data Contains the name of the product family company logo and information about the power data of the device 2 Identification Contains the device number with unique serial number and...

Page 43: ...nnection Grounding on page 44 10 ETH1 Ethernet 1 interface ETH1 on page 45 3 USB2 USB interfaces on page 46 11 On Off Terminating resistor on page 1641 4 USB1 USB interfaces on page 46 12 L1 L2 L3 LED...

Page 44: ...Model number Short description Terminal blocks 0TB103 9 Connector 24 V 5 08 3 pin screw clamp terminal block 0TB103 91 Connector 24 V 5 08 3 pin cage clamp terminal block Power supply connection 3 pi...

Page 45: ...loads section of the B R website www br automation com Information Necessary drivers must be downloaded from the B R website not from manufacturer websites 2 2 5 4 Ethernet 2 interface ETH2 This Ether...

Page 46: ...ion this interface must be handled with the utmost care with regard to EMC cable routing etc Universal Serial Bus USB1 USB2 1 Type USB 3 0 Variant Type A Transfer rate Low speed 1 5 Mbit s full speed...

Page 47: ...s Information 5CFAST 0xxx 00 CFast cards are only permitted to be operated in the xPC2200 starting with revision E0 CFast slot Connection SATA 0 Model number Short description CFast cards 5CFAST 2048...

Page 48: ...d in the op erating system when pressing the power button shutdown sleep etc and switches off the Panel PC Long press The ATX power supply switches off the Panel PC without shutting it down approx 4 s...

Page 49: ...update power supply OK Faulty or incomplete BIOS MTCX or I O FPGA update pow er saving standby mode S5 soft off mode or S4 hiberna tion suspend to disk mode Faulty or incomplete BIOS MTCX or I O FPGA...

Page 50: ...s battery For APC2200 PPC2200 Table 49 Battery compartment The battery state is determined by the system immediately after the device is switched on and subsequently every 24 hours During the measurem...

Page 51: ...C2200 5ACCIF01 FPLS 000 Interface card 1x RS232 interface 1x POWERLINK interface 32 kB FRAM For APC2100 PPC2100 and APC2200 PPC2200 5ACCIF01 FPLS 001 Interface card 1x RS232 interface 1x POWERLINK in...

Page 52: ...in BIOS 1 In submenu Security of Setup utility set parameter TPM availability to Available 2 Apply this setting with Save and exit The change only takes effect after a reboot which takes place auto ma...

Page 53: ...Yes Yes Yes 12 1 single touch 5AP1120 1214 000 SVGA Single touch No No Yes 12 1 single touch 5AP1120 121E 000 WXGA Single touch No No No 12 1 multi touch 5AP1130 121E 000 WXGA Multi touch No No No 15...

Page 54: ...er in a bit string of 128 bits each The positions of the keys and LEDs in the matrix are represented as hardware numbers The hardware numbers can be read directly from the target system using the B R...

Page 55: ...00 built in devices User s manual V 1 05 Translation of the original documentation 55 5AP1180 1043 000 Figure 27 5AP1180 1043 000 Key and LED configuration 5AP1181 1043 000 Figure 28 5AP1181 1043 000...

Page 56: ...2200 built in devices User s manual V 1 05 Translation of the original documentation 5AP1182 1043 000 Figure 29 5AP1182 1043 000 Key and LED configuration 5AP1180 1505 000 Figure 30 5AP1180 1505 000...

Page 57: ...Technical data Panel PC 2200 built in devices User s manual V 1 05 Translation of the original documentation 57 5AP1181 1505 000 Figure 31 5AP1181 1505 000 Key and LED configuration...

Page 58: ...ed Caution Due to the general PC specification this interface must be handled with the utmost care with regard to EMC cable routing etc Front USB The front USB interface is available to the user for s...

Page 59: ...00 AP900 AP1000 PPC700 and PPC800 devices For more information see section Compatibility details on page 60 Information The cutout tolerance for the PP100 200 PP300 400 PP500 AP900 PPC700 and PPC800 i...

Page 60: ...nation AP1000 refers to the Automation Panel 1000 as well as to Panel PCs installed on AP1000 panels 2 2 7 2 Compatibility details 2 2 7 2 1 Example The dimensions mm in the subsequent figures have th...

Page 61: ...atibility 5 7 devices Landscape1 The 5 7 Automation Panel 1000 Power Panel 500 Power Panel 300 400 and Power Panel 100 200 devices in Landscape1 format are 100 compatible 302 x 187 6 5 6 5 6 5 6 5 PP1...

Page 62: ...mation Panel 1000 and Power Panel 500 are not 100 compatible with Power Panel 300 400 and Power Panel 100 200 devices in Portrait1 format Automation Panel 1000 and Power Panel 500 devices need a cutou...

Page 63: ...ut for AP900 PPC700 device 4 5 423 x 288 10 10 8 5 402 x 271 402 x 266 5 403 x 271 PP500 Cutout for PP500 AP1000 device AP1000 0 5 13 PP100 200 300 400 8 5 AP900 PPC700 8 5 PP500 AP1000 Figure 37 Inst...

Page 64: ...Automation Panel 900 Panel PC 700 and Power Panel 500 devices are not 100 compatible with Power Panel 300 400 or Power Panel 100 200 devices in Portrait1 format Automation Panel 1000 Automation Panel...

Page 65: ...C700 PP500 AP1000 Cutout for AP900 PPC700 PP500 AP1000 device 1 5 342 x 267 345 x 267 PP500 AP1000 Figure 39 Installation compatibility 12 1 devices Landscape1 12 1 Automation Panel 1000 Automation Pa...

Page 66: ...to ensure that the PP100 200 PP300 400 AP900 PPC700 and PPC800 devices are positioned and installed as centrally as possible in the cutout If this is not the case the retaining clips can no longer gri...

Page 67: ...stallation compatibility 17 devices Landscape1 The 17 Automation Panel 900 and Panel PC 700 in Landscape1 format are 100 compatible 2 2 7 2 7 19 devices The cutout tolerance for the PP100 200 PP300 40...

Page 68: ...n 2 2 7 2 8 21 3 devices The cutout tolerance for the PP100 200 PP300 400 PP500 AP900 PPC700 and PPC800 is 0 5 mm The cutout tolerance for the AP1000 is 0 mm 0 5 mm 583 x 464 8 5 8 5 8 5 8 5 Outer con...

Page 69: ...tures and limit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in whic...

Page 70: ...00 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2 At 25 C ambient temperature R...

Page 71: ...system The data specified for the complete system applies to the complete system in which this individual component is used for example Model number 5AP923 1505 00 General information B R ID code 0xE1...

Page 72: ...nstalled in the complete system have this certification and the complete system bears the corresponding mark 2 Yes but applies only if all components installed in the complete system have this certifi...

Page 73: ...l PC 2200 built in devices User s manual V 1 05 Translation of the original documentation 73 Diagram legend 1 Operation T C Temperature in C 2 Storage and transport RH Relative humidity RH in percent...

Page 74: ...this individual component is used for example Model number 5AP923 1906 00 Revision D0 E0 General information B R ID code 0xE1B1 Certifications CE Yes UL cULus E115267 Industrial control equipment HazL...

Page 75: ...ht 358 mm Weight 5800 g Table 60 5AP923 1906 00 5AP923 1906 00 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system...

Page 76: ...AP923 1906 00 Rev E0 Temperature Humidity diagram Diagram legend 1 Operation T C Temperature in C 2 Storage and transport RH Relative humidity RH in percent and non condensing T C 0 100 100 0 80 5 10...

Page 77: ...system in which this individual component is used for example Model number 5AP933 156B 00 Revision C0 D0 General information B R ID code 0xE16A Certifications CE Yes UL cULus E115267 Industrial contr...

Page 78: ...ss time by approximately 50 2 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Multi touch drivers 2 3 1 4 4 Dimensions 414 258 5 Figure 52 5AP9...

Page 79: ...tation 79 T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 54 5AP933 156B 00 Rev C0 Temperature Humidity diagram Diagram legend 1 Operat...

Page 80: ...e system applies to the complete system in which this individual component is used for example Model number 5AP933 185B 00 Revision C0 D0 General information B R ID code 0xE16B Certifications CE Yes U...

Page 81: ...ss time by approximately 50 2 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Multi touch drivers 2 3 1 5 4 Dimensions 295 475 Figure 55 5AP933...

Page 82: ...mentation T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 57 5AP933 185B 00 Rev C0 Temperature Humidity diagram Diagram legend 1 Operat...

Page 83: ...system applies to the complete system in which this individual component is used for example Model number 5AP933 215C 00 Revision C0 D0 General information B R ID code 0xE16C Certifications CE Yes UL...

Page 84: ...ss time by approximately 50 2 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Multi touch drivers 2 3 1 6 4 Dimensions 541 5 333 Figure 58 5AP9...

Page 85: ...tation 85 T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 60 5AP933 215C 00 Rev C0 Temperature Humidity diagram Diagram legend 1 Operat...

Page 86: ...lete system applies to the complete system in which this individual component is used for example Model number 5AP933 240C 00 Revision C0 D0 General information B R ID code 0xE1B4 Certifications CE Ye...

Page 87: ...system have this certification and are listed on the associated DNV GL certificate for the product family 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness...

Page 88: ...rage and transport RH Relative humidity RH in percent and non condensing T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 63 5AP933 240C...

Page 89: ...those of the complete system The data specified for the complete system applies to the complete system in which this individual component is used for example Model number 5AP1120 0573 000 Revision D0...

Page 90: ...led in the complete system have this certification and the complete system bears the corresponding mark 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness tim...

Page 91: ...ation 91 T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 66 5AP1120 0573 000 Rev D0 Temperature Humidity diagram Diagram legend 1 Opera...

Page 92: ...the complete system The data specified for the complete system applies to the complete system in which this individual component is used for example Product ID 5AP1151 0573 000 Revision D0 E0 General...

Page 93: ...ght 1400 g Table 72 5AP1151 0573 000 5AP1151 0573 000 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the...

Page 94: ...entation T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 69 5AP1151 0573 000 Rev D0 Temperature Humidity diagram Diagram legend 1 Opera...

Page 95: ...or the complete system applies to the complete system in which this individual component is used for example Model number 5AP1120 0702 000 General information B R ID code 0xE7AC Certifications CE Yes...

Page 96: ...ponding mark 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 Touch screen drivers for approved operating systems are available f...

Page 97: ...ete system applies to the complete system in which this individual component is used for example Model number 5AP1130 0702 000 General information B R ID code 0xEB61 Certifications CE Yes UL cULus E11...

Page 98: ...educing the brightness by 50 can increase the half brightness time by approximately 50 3 The specifications for the touch screen driver must be taken into account See chapter 4 Software section 2 Mult...

Page 99: ...omplete system applies to the complete system in which this individual component is used for example Model number 5AP1120 101E 000 General information B R ID code 0xE93D Certifications CE Yes UL cULus...

Page 100: ...mark 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 Touch screen drivers for approved operating systems are available for downl...

Page 101: ...tem applies to the complete system in which this individual component is used for example Model number 5AP1130 101E 000 General information B R ID code 0xEB62 Certifications CE Yes UL cULus E115267 In...

Page 102: ...Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Mult...

Page 103: ...only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this individual componen...

Page 104: ...ester Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 323 mm Height 260 mm Weight 2800 g Table 82 5AP1120 1043 000 Technical data 1 Yes but...

Page 105: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 79 5AP1120 1043 000 Temperature Humidity diagram Diagra...

Page 106: ...res and limit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which...

Page 107: ...operties Front 4 Frame Aluminum naturally anodized Keypad overlay Material Polyester Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 323 mm...

Page 108: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 81 5AP1180 1043 000 Temperature Humidity diagram Diagra...

Page 109: ...nical data Information The following specified characteristic data features and limit values are only valid for these individual components and may differ from those of the complete system The data sp...

Page 110: ...ion per UL 50 Front Type 4X indoor use only Mechanical properties Front 4 Frame Aluminum naturally anodized Keypad overlay Material Polyester Light background RAL 9006 Dark gray border around display...

Page 111: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 83 5AP1181 1043 000 Temperature Humidity diagram Diagra...

Page 112: ...ed characteristic data features and limit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to t...

Page 113: ...chanical properties Front 4 Frame Aluminum naturally anodized Keypad overlay Material Polyester Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions W...

Page 114: ...0 5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 85 5AP1182 1043 000 Temperature Humidity diagram Diagr...

Page 115: ...re only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this individual compon...

Page 116: ...ster Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 362 mm Height 284 mm Weight 3200 g Table 90 5AP1120 1214 000 Technical data 1 Yes but...

Page 117: ...1 5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 87 5AP1120 1214 000 Temperature Humidity diagram Diagr...

Page 118: ...e complete system applies to the complete system in which this individual component is used for example Model number 5AP1120 121E 000 General information B R ID code 0xE8E4 Certifications CE Yes UL cU...

Page 119: ...ark 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 Touch screen drivers for approved operating systems are available for downlo...

Page 120: ...ystem applies to the complete system in which this individual component is used for example Model number 5AP1130 121E 000 General information B R ID code 0xEB63 Certifications CE Yes UL cULus E115267...

Page 121: ...Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Multi...

Page 122: ...ures and limit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which...

Page 123: ...ster Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 435 mm Height 330 mm Weight 5000 g Table 96 5AP1120 1505 000 Technical data 1 Yes but...

Page 124: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 8 Figure 93 5AP1120 1505 000 Temperature Humidity diagram Diag...

Page 125: ...nd limit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this...

Page 126: ...perties Front 4 Frame Aluminum naturally anodized Keypad overlay Material Polyester Light background RAL 9006 Dark gray border around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 435 mm...

Page 127: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 8 Figure 95 5AP1180 1505 000 Temperature Humidity diagram Diag...

Page 128: ...with 5PP581 1505 000 Table 99 5AP1181 1505 000 Order data 2 3 2 16 3 Technical data Information The following specified characteristic data features and limit values are only valid for these individu...

Page 129: ...r EN 60529 Front IP65 Back IP20 only with installed link module or installed system unit Protection per UL 50 Front Type 4X indoor use only Mechanical properties Front 4 Frame Aluminum naturally anodi...

Page 130: ...P1181 1505 000 Dimensions 2 3 2 16 5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 8 Figure 97 5AP1181 1505 000...

Page 131: ...d for the complete system applies to the complete system in which this individual component is used for example Model number 5AP1120 156B 000 General information B R ID code 0xE8E5 Certifications CE Y...

Page 132: ...ark 2 At 25 C ambient temperature Reducing the brightness by 50 can increase the half brightness time by approximately 50 3 Touch screen drivers for approved operating systems are available for downlo...

Page 133: ...iffer from those of the complete system The data specified for the complete system applies to the complete system in which this individual component is used for example Model number 5AP1130 156C 000 G...

Page 134: ...ification and the complete system bears the corresponding mark 2 Yes but applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL...

Page 135: ...l PC 2200 built in devices User s manual V 1 05 Translation of the original documentation 135 Diagram legend 1 Operation T C Temperature in C 2 Storage and transport RH Relative humidity RH in percent...

Page 136: ...mplete system applies to the complete system in which this individual component is used for example Model number 5AP1130 185C 000 General information B R ID code 0xEC5E Certifications CE Yes UL cULus...

Page 137: ...educing the brightness by 50 can increase the half brightness time by approximately 50 3 The specifications for the touch screen driver must be taken into account See chapter 4 Software section Multi...

Page 138: ...mit values are only valid for these individual components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this indiv...

Page 139: ...order around display RAL 7024 Gasket 3 mm fixed gasket Dimensions Width 527 mm Height 421 mm Weight 7300 g Table 108 5AP1120 1906 000 Technical data 1 Yes but applies only if all components installed...

Page 140: ...5 Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 105 5AP1120 1906 000 Temperature Humidity diagram Diagr...

Page 141: ...nterface 1x POWERLINK interface 512 kB nvSRAM For APC2100 PPC2100 APC2200 PPC2200 Only available with a new de vice 5ACCIF01 FPCS 000 Interface card 1x RS485 interface 1x CAN interface 1x POWERLINK in...

Page 142: ...Thermal design power TDP 6 5 W 9 5 W L2 cache 2 MB Intel 64 architecture Yes Intel Hyper Threading Technology No Intel vPro Technology No Intel Virtualization Technology VT x Yes Intel Virtualization...

Page 143: ...ed 6 Environmental conditions Elevation Operation Max 3000 m component dependent 7 Mechanical characteristics Dimensions Width 190 mm Height 115 mm Depth 29 7 mm Weight 577 g Table 110 5PPC2200 AL02 0...

Page 144: ...T MLC flash technology is increasingly finding its way into this market 2 3 4 2 2 Wear leveling Wear leveling refers to an algorithm that can be used to maximize the service life of a CFast card A dis...

Page 145: ...medium via S M A R T Fully operate the system with the relevant data storage medium over a defined period of time e g 1 week Determine the used erase cycles via Average erase count Determine the expe...

Page 146: ...previous revisions when using old cloning tools With current cloning tools this behavior usually does not occur Information The following specified characteristic data features and limit values are on...

Page 147: ...0 PPC3100 PPC2200 PPC2100 PPC900 Operating systems Windows 10 IoT Enterprise LTSB 64 bit No No No No Yes Windows Embedded 8 1 Industry Pro 32 bit No No No Yes Yes Windows Embedded 8 1 Industry Pro 64...

Page 148: ...and data retention of the data storage medium 2 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 3 Y...

Page 149: ...slation of the original documentation 149 2 3 4 3 5 Dimensions 1 0 2 0 1 12 0 1 36 4 0 15 42 8 0 1 41 6 0 13 1 0 1 13 8 0 1 3 0 07 2 3 0 1 1 15 0 1 0 6 0 07 0 7 0 07 4 5 0 1 25 63 0 1 1 0 07 1 0 05 33...

Page 150: ...eatures and limit values are only valid for this accessory and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this acce...

Page 151: ...t 40 to 85 C Relative humidity Operation Max 85 at 85 C non condensing Storage Max 85 at 85 C non condensing Transport Max 85 at 85 C non condensing Vibration Operation 10 to 2000 Hz 20 g peak Storage...

Page 152: ...y diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 1 2 Figure 109 5CFAST 032G 10 5CFAST 064G 10 5CFAST 128G 10 5CFAST 256G 10 Temperature H...

Page 153: ...th a new de vice Optional accessories Terminal blocks 0TB1210 3100 Connector 300 VDC 10 pin female Cage clamp terminal block Protected against vibration by the screw flange Table 115 5ACCIF01 FPCC 000...

Page 154: ...lete system have this certification and the complete system bears the corresponding mark 2 Yes but applies only if all components installed in the complete system have this certification and are liste...

Page 155: ...as IF3 in Automation Studio Automation Runtime It is not a PC interface and therefore not displayed in BIOS CAN driver settings The baud rate can be set either with predefined values or via the bit t...

Page 156: ...istor is switched on or off The terminating resistor cannot be switched on and off for the CAN bus 2 interface Terminating resistor On The terminating resistor is switched on Off The terminating resis...

Page 157: ...missible oscillator tolerance of 0 121 Extension Transfer rate 1000 m Typ 50 kbit s 200 m Typ 250 kbit s 100 m Typ 500 kbit s 20 m1 Typ 1 Mbit s Table 125 CAN2 Bus length and transfer rate 1 The speci...

Page 158: ...interfaces can be connected to pin Shield of the female connector In addition there is a functional ground connection on the interface cover of the system unit and a screw point for cable shields tha...

Page 159: ...rted Controlled node CN The bus is monitored for POWERLINK frames If no corresponding frame is received in the set time window timeout the module immediately enters mode BASIC_ETHERNET flickering If P...

Page 160: ...rface is in state OPERATIONAL PDO mapping is active and cyclic data is evaluated Blinking approx 2 5 Hz STOPPED State The interface is in state STOPPED Managing node MN This state is not possible in t...

Page 161: ...01 FPCS 000 Order data 2 3 5 2 3 Technical data Information The following specified characteristic data features and limit values are only valid for this accessory and may differ from those of the com...

Page 162: ...ommunication POWERLINK General Hardware IF LS 2 3 5 2 3 1 POWERLINK interface Pinout The POWERLINK interface on the system unit is referred to as IF option POWERLINK1 2 Wiring S STP Cat 5e Cable lengt...

Page 163: ...al used should have the following properties or deviate only slightly from them in order to achieve an optimal transfer rate RS485 cables Property Signal line Cable cross section 4x 0 25 mm 24AWG 19 t...

Page 164: ...d with the values specified in Tab 139 CAN driver settings Otherwise the cable lengths depend on the values in the timing register Preferably the cable material used should have the following properti...

Page 165: ...een Blinking POWERLINK link LED Data is being transferred On POWERLINK status error LED See Status Error LED L3 Green Red Off POWERLINK status error LED See Status Error LED L2 L1 L3 Table 144 5ACCIF0...

Page 166: ...mmunication is not yet taking place Controlled node CN In this state the module can be configured by the MN The CN waits for the reception of as SoC frame and then changes to state PRE_OPERATIONAL_2 d...

Page 167: ...every 2 seconds Error description Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is def...

Page 168: ...ntime Information Ring redundancy in combination with poll response chaining is not possible at the same time with this IF option 2 3 5 3 2 Order data Model number Short description Figure Interface o...

Page 169: ...Table 150 5ACCIF01 FPLK 000 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2 For...

Page 170: ...3 3 3 LED status indicators L1 L2 L3 The LEDs of the interface option are located near the ETH1 interface LED status indicators LED Color Status Explanation On POWERLINK 2 link LED A connection to a...

Page 171: ...rted Controlled node CN The bus is monitored for POWERLINK frames If no corresponding frame is received in the set time window timeout the module immediately enters mode BASIC_ETHERNET flickering If P...

Page 172: ...rface is in state OPERATIONAL PDO mapping is active and cyclic data is evaluated Blinking approx 2 5 Hz STOPPED State The interface is in state STOPPED Managing node MN This state is not possible in t...

Page 173: ...limit values are only valid for this accessory and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this accessory is ins...

Page 174: ...ED Status On Off Green See status error LED LED Link On Off Yellow Link a connec tion to a POWER LINK network exists Activity blinks data is being transferred RJ45 female LED Status 1 LED Link Table 1...

Page 175: ...atus indicators Status Error LED The status error LED is designed as a green and red dual LED The LED statuses have a different meaning depending on the operating mode Ethernet mode In this mode the i...

Page 176: ...mmunication is not yet taking place Controlled node CN In this state the module can be configured by the MN The CN waits for the reception of as SoC frame and then changes to state PRE_OPERATIONAL_2 d...

Page 177: ...rface or a system component is defective and must be replaced Pause Pause Table 166 System stop error codes Legend 150 ms 600 ms Pause 2 s pause 2 3 5 4 3 4 Shielding For the interfaces on the 10 pin...

Page 178: ...lues are only valid for this accessory and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this accessory is installed f...

Page 179: ...ransferred RJ45 female LED Status 1 LED Link Table 169 5ACCIF01 FPLS 001 POWERLINK interface 1 The interfaces etc available on the device or module have been numbered for the purpose of clear differen...

Page 180: ...atus indicators Status Error LED The status error LED is designed as a green and red dual LED The LED statuses have a different meaning depending on the operating mode Ethernet mode In this mode the i...

Page 181: ...mmunication is not yet taking place Controlled node CN In this state the module can be configured by the MN The CN waits for the reception of as SoC frame and then changes to state PRE_OPERATIONAL_2 d...

Page 182: ...rface or a system component is defective and must be replaced Pause Pause Table 175 System stop error codes Legend 150 ms 600 ms Pause 2 s pause 2 3 5 5 3 4 Shielding For the interfaces on the 10 pin...

Page 183: ...flange Table 176 5ACCIF01 FPSC 000 Order data 2 3 5 6 3 Technical data Information The following specified characteristic data features and limit values are only valid for this accessory and may diffe...

Page 184: ...if all components installed in the complete system have this certification and the complete system bears the corresponding mark 2 Yes but applies only if all components installed in the complete syste...

Page 185: ...isolation Transfer rate Max 1 Mbit s Bus length Max 1000 m Pin Pinout 1 2 Shield 3 4 5 CAN H 6 CAN L 7 CAN GND 8 9 10 10 pin male 1 3 5 7 2 4 6 8 10 9 Table 180 5ACCIF01 FPSC 000 CAN bus interface 1...

Page 186: ...ss section Wire insulation Conductor resistance 1x 0 34 mm 22AWG 19 tinned copper stranded wire PE 59 km Outer jacket Material Properties Cable shield PUR compound Halogen free Composed of tinned copp...

Page 187: ...us Error LED L2 L1 L3 Table 185 5ACCIF01 FPSC 000 LED status indicators Status Error LED The status error LED is designed as a green and red dual LED The LED statuses have a different meaning dependin...

Page 188: ...mmunication is not yet taking place Controlled node CN In this state the module can be configured by the MN The CN waits for the reception of as SoC frame and then changes to state PRE_OPERATIONAL_2 d...

Page 189: ...every 2 seconds Error description Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is def...

Page 190: ...VDC 10 pin female Cage clamp terminal block Protected against vibration by the screw flange Table 190 5ACCIF01 FPSC 001 Order data 2 3 5 7 3 Technical data Information The following specified charact...

Page 191: ...5 non condensing Mechanical characteristics Weight 25 g Table 191 5ACCIF01 FPSC 001 Technical data 1 Yes but applies only if all components installed in the complete system have this certification and...

Page 192: ...ector Transfer rate Max 1 Mbit s Bus length Max 1000 m Pin Pinout 1 2 Shield 3 4 5 CAN H 6 CAN L 7 CAN GND 8 9 10 10 pin male 1 3 5 7 2 4 6 8 10 9 Table 194 5ACCIF01 FPSC 001 CAN bus interface 1 The i...

Page 193: ...AN cable requirements Terminating resistor A terminating resistor is integrated on the interface option It is located near the ETH1 interface A switch is used to switch the terminating resistor for th...

Page 194: ...L2 Green Blinking POWERLINK link LED Data is being transferred On POWERLINK status error LED See Status Error LED L3 Green Red Off POWERLINK status error LED See Status Error LED L2 L1 L3 Table 200 5A...

Page 195: ...mmunication is not yet taking place Controlled node CN In this state the module can be configured by the MN The CN waits for the reception of as SoC frame and then changes to state PRE_OPERATIONAL_2 d...

Page 196: ...every 2 seconds Error description Error code indicated by red Status LED RAM error The interface is defective and must be replaced Pause Pause Hardware error The interface or a system component is def...

Page 197: ...data features and limit values are only valid for this accessory and may differ from those of the complete system The data specified for the complete system applies to the complete system in which th...

Page 198: ...D 9 RXD 10 RXD 10 pin male 1 3 5 7 2 4 6 8 10 9 Table 207 5ACCIF01 FSS0 000 Interface COM A 1 The interfaces etc available on the device or module have been numbered for the purpose of clear different...

Page 199: ...y deviate from the numbering used by the respective operating system however 2 This interface if available is automatically enabled in BIOS as COM D with default addresses I O 2E8h and IRQ 5 3 In Auto...

Page 200: ...stranded wire Wire insulation PE Conductor resistance 59 km Outer jacket Material PUR compound Properties Halogen free Cable shield Tinned copper wire Table 210 RS485 cable requirements 2 3 5 8 3 4 R...

Page 201: ...istor Table 213 Terminating resistor 2 3 5 8 3 6 Shielding The shields of the cables connected to the female 10 pin connector can be connected to the screw point for cable shields see Device interface...

Page 202: ...is accessory is installed for example Model number 5ACCIF01 ICAN 000 General information LED status indicators L1 B R ID code 0xE9BB Certifications CE Yes UL cULus E115267 Industrial control equipment...

Page 203: ...ction 384h address register Defines the register number to be accessed I O address 385h data register Access to the register defined in the address register IRQ IRQ 10 Interrupt Table 218 I O address...

Page 204: ...the terminating resistor for the CAN bus interface on and off LED status indicator L1 indicates whether the terminating resistor is switched on or off Terminating resistor On The terminating resistor...

Page 205: ...mponent is used for example Model number 5ACCIF03 CETH 000 General information B R ID code F1A8 Diagnostics Data transfer Yes using LED status indicator Certifications CE Yes UL cULus E115267 Industri...

Page 206: ...tc available on the device or module have been numbered for the purpose of clear differentiation This numbering may deviate from the numbering used by the respective operating system however 2 Switchi...

Page 207: ...000 on page 282 in section Replacement parts 2 3 6 1 3 Technical data Model number 5ACCBT01 0000 001 General information Battery Type Panasonic 1000 mAh Service life 8 years 1 Removable No 2 Design Li...

Page 208: ...ed effect on the device Damaged packaging indicates that the device has been severely affected by environ mental influences and may have been damaged This can result in malfunctions of the device mach...

Page 209: ...surface installation cutout mounting surface requirements are met Permissible deviation from the evenness on the installation cutout 0 5 mm Permissible surface roughness in the area of the installati...

Page 210: ...umber of retaining clips depends on the panel The thickness of the wall or control cabinet plate must be at least 1 mm and is not permitted to exceed 6 mm A 2 5 mm hex screwdriver is needed to tighten...

Page 211: ...retaining clips may vary depending on the panel For the exact number see Fig 4 Panel PC 2200 with AP9x3 panels Installation diagram on page 21 Figure 113 Inserting the retaining clips 4 Secure the re...

Page 212: ...ewdriver is needed to tighten and remove the screw on the retaining clips The maximum tightening torque of the retaining clips is 1 Nm The device must be installed on a flat clean and burr free surfac...

Page 213: ...taining clips may vary depending on the panel For the exact number see Tab 14 AP1000 panels with retaining clips Installation diagrams on page 22 Figure 116 Inserting the retaining clips 4 Secure the...

Page 214: ...d is not permitted to exceed 10 mm A 3 mm hex screwdriver is needed to tighten or remove the screw on the clamping block The maximum tightening torque of the screw is 0 5 Nm The device must be install...

Page 215: ...trol cabinet plate by alternately tightening the mounting screws with a 3 mm hex screwdriver The mounting screws push the clamping lever downwards which in turn clamps the device to the wall or contro...

Page 216: ...unit 1 Disconnect the power supply cable to the Panel PC disconnect the power cable Disconnect from all sources and poles 2 Carry out electrostatic discharge at the ground connection 3 Remove the Pan...

Page 217: ...elow Conductors with a cross section of 0 75 mm2 to 1 5 mm2 and wire end sleeve must be used Installing screw clamp terminal block 0TB103 9 Secure the conductors with wire end sleeves in the terminal...

Page 218: ...e must be interrupted Before connecting the power cable it must be checked whether it has been disconnected from the voltage source e g power supply 1 Carry out electrostatic discharge on the housing...

Page 219: ...ollowing points must be observed to ensure that electrical interference is safely diverted Connect the device to the central grounding point e g the control cabinet or the system using the shortest po...

Page 220: ...When connecting or installing cables the bend radius specification must be observed Information The maximum tightening torque of the locating screws is 0 5 Nm Bend radius Locating screws Locating scr...

Page 221: ...are the device must have been started up Caution Before the device is started up it must be gradually adapted to room temperature Exposure to direct heat radiation is not permitted During transport at...

Page 222: ...ust air Every B R industrial PC or Power Panel is equipped with internal temperature sensors Depending on the device family these are installed in different positions The number and temperature limits...

Page 223: ...ftware package various loopback adapters serial parallel USB etc and test CDs or DVDs are also available Depending on the expansion level of the software and available loopback adapters a correspondin...

Page 224: ...rties Information If no USB loopback adapters are available USB flash drives can also be used The USB flash drives must be available in Windows as formatted drives Option USB must then be deselected i...

Page 225: ...ement results The recorded maximum temperature value of each individual sensor is not permitted to exceed the temperature limit specified in the user s manuals If the temperature tests cannot be carri...

Page 226: ...automatically On all other devices the touch screen driver must be subsequently installed to operate the touch screen The appropriate driver is available for download in the Downloads section of the...

Page 227: ...nels are displayed in the list 4 Set the desired brightness using the slider Figure 130 Adjusting the display brightness Information The changed settings are displayed online but only applied by the s...

Page 228: ...1 05 Translation of the original documentation 3 8 Known problems Characteristics If problems occur with the ETH1 or ETH2 interface connection abort slow data transfer etc the Ener gy Efficient Ether...

Page 229: ...s The APC2200 PPC2200 can still be used with standard displays and operator panels without sacrificing user friend liness however 4 1 1 2 Overview of BIOS description Note This description is for the...

Page 230: ...3 BIOS parameter 2 Displays BIOS parameter 2 a1 a2 BIOS parameter 2 1 b Selects mode of BIOS parameter 2 1 Disable d BIOS subpa rameter 2 1 value Enable d Disables Enables BIOS subparameter 2 1 Disabl...

Page 231: ...loaded and the boot process is continued UEFI BIOS reads the system configuration information checks the system and configures it through the power on self test POST UEFI BIOS then searches the data...

Page 232: ...on page 233 Device management Lists all supported and enabled devices e g RAID and Ethernet See Device manager on page 234 Boot from file Selects a bootable file to boot from Depending on the boot co...

Page 233: ...V 1 05 Translation of the original documentation 233 4 1 4 Boot manager Figure 133 Boot manager The boot manager lists all detected and bootable legacy or UEFI media It is possible to select from whic...

Page 234: ...lation of the original documentation 4 1 5 Device manager Figure 134 Device manager The device manager lists all compatible and enabled devices BIOS parameter Setting options Description PCI Primary v...

Page 235: ...here Security Enter Opens submenu Security on page 247 Changes to the Trusted Platform Module can be made here Passwords for storage media can be created and managed here Power Enter Opens submenu Po...

Page 236: ...nnel A DIMM 0 Displays the amount of memory for channel A Channel B DIMM 0 Displays the amount of memory for channel B Channel C SODIMM 0 Displays the amount of memory for channel C Channel D SODIMM 0...

Page 237: ...s Description OEM features Enter Opens submenu OEM features on page 238 Graphics configuration Enter Opens submenu Graphics configuration on page 242 IO configuration Enter Opens submenu IO configurat...

Page 238: ...E on page 239 Baseboard Enter Opens submenu Baseboard on page 239 Interface slot n1 2 Enter Opens submenu Interface slot n on page 240 Panel settings Enter Opens submenu Panel settings on page 240 SSD...

Page 239: ...IRQ7 Interrupt IRQ11 Selects the interrupt for COM D Table 236 Advanced OEM features Super IO 4 1 6 2 1 2 H2OUVE BIOS parameter Setting options Description Disabled H2OUVE support Enabled Disables En...

Page 240: ...es Interface slot n 1 For graphics options only 2 Each start restart increases the value by 1 3 Depending on the IF option card the number of temperature sensors varies from 0 parameter not displayed...

Page 241: ...S M A R T status of the CFast card WAF2 Displays the WAF of the CFast card Average erase count Displays the average number of erase operations on a block of the CFast card Remaining life Displays the...

Page 242: ...ed amount of memory is made available DVMT2 pre allocated Various Default 64M Defines the allocated graphics memory DVMT MB to be used by the IGD Range 64M to 512M 128M 256M DVMT total Gfx mem MAX Sel...

Page 243: ...bles Enables PCI Express root port n manually or automatically In mode Auto unallocated interfaces are automatically disabled and allocated inter faces are enabled Auto Disabled L0sL1 L0s ASPM L1 Sele...

Page 244: ...PCIe selectable de emphasis Table 246 Advanced PCH IO configuration PCI Express root port n 1 PCI Express root port n must be enabled in order to make further configurations 2 With a multifunction dev...

Page 245: ...on Enabled Disables Enables the USB 2 0 interface on the IF option Table 248 Advanced IO configuration USB configuration 4 1 6 2 3 4 Miscellaneous configuration BIOS parameter Setting options Descript...

Page 246: ...dvanced Security configuration 1 Intel Trusted Execution Engine 4 1 6 2 5 ACPI settings BIOS parameter Setting options Description ACPI settings Enter Opens submenu ACPI settings on page 246 Disabled...

Page 247: ...lgorithm TPM hardware supported hash algorithm Displays the hash algorithms supported by the hardware 1 0 TrEE protocol version 1 1 Selects the TrEE protocol version Hidden TPM availability Available...

Page 248: ...ey pad Defines the time for wake from S5 by every day hh mm ss hh range 0 to 23 mm and ss range 0 to 59 Day of month INT Default 1 Defines the day of the month for waking from S5 by day of month Range...

Page 249: ...echnology Power limit 1 Displays power limit 1 W Power limit 2 Displays power limit 2 W Disabled Power limit 1 enable Enabled Disables Enables power limit 1 PL1 Disabled Power limit 1 clamp mode Enabl...

Page 250: ...aster Disabled Quiet boot Enabled Disables Enables booting in text mode Disabled Network stack Enabled Disables Enables the network stack Enabling makes ETH booting possible Disabled UEFI IPV4 UEFI IP...

Page 251: ...CFast eMMC USB device Internal EFI shell ETH1 IPv4 ETH1 IPv6 ETH2 IPv4 ETH2 IPv6 USB CD ROM Other 1st device Disabled Selects this device as first in the boot order 2nd device1 eMMC Selects this devic...

Page 252: ...orresponding device is available Their structure corresponds to that of submenu Hard disk drive 4 1 6 5 2 1 Boot type order BIOS parameter Setting options Description Boot type order Enter then Keyboa...

Page 253: ...anges and restarts Save changes without exit Enter Saves changes Some settings only take effect after a restart Exit discarding changes Enter Discards changes and exits Load optimal defaults Enter Loa...

Page 254: ...to add newly implemented functions or com ponents for information about changes see the readme file of the UEFI BIOS upgrade 4 2 1 1 UEFI BIOS What do I need to know Information During a UEFI BIOS upg...

Page 255: ...rade Panel PC 2200 With Firmware upgrade MTCX it is possible to update the firmware depending on the version of the PPC2200 system A current firmware upgrade can be downloaded directly from the Downlo...

Page 256: ...6 or FAT32 Alternatively a CFast card can also be used 3 Reboot the PC and select Internal shell as the boot device Esc Del or F2 key to open the boot menu 4 After booting the EFI shell startup nsh is...

Page 257: ...vided as a ZIP file and include a readme file that provides additional information For automatic upgrades the upgrade files must be stored off of the root directory of a data storage medium for matted...

Page 258: ...SB Windows 10 IoT Enterprise 2015 LTSB Windows Embedded 8 1 Industry Pro Windows 7 Professional Ultimate Windows Embedded Standard 7 Premium B R Linux 8 and 9 No guarantee can be given for multi touch...

Page 259: ...oft B R recommends using 4 GB RAM or more for 64 bit operating systems 4 4 4 Features The feature list shows the most important device functions in Windows 10 IoT Enterprise 2016 LTSB Function Windows...

Page 260: ...d by special B R extensions in the operating system and theoretically not lost when the hardware is changed e g replacement of components in the event of repair or when the system is reinstalled unlik...

Page 261: ...version cause different behavior com pared to a standard Windows 10 Enterprise installation 4 4 9 Supported display resolutions Per Microsoft requirements Windows 10 IoT Enterprise 2016 LTSB requires...

Page 262: ...CFast 128 GB MLC 5CFAST 256G 10 CFast 256 GB MLC 5CFAST 4096 00 CFast 4 GB SLC 5CFAST 8192 00 CFast 8 GB SLC Table 267 5SWLIN 0745 MUL Order data 4 5 3 Overview Material number Target sys tem Chipset...

Page 263: ...ginal documentation 263 4 5 6 Drivers Current drivers for all approved operating systems are available for download in the Downloads section of the B R website www br automation com Information Necess...

Page 264: ...out possible alarms or hardware mal functions can be drawn from this The hardware components used have automatic diagnostic func tions in the event of error 4 6 1 Functions Information The functions a...

Page 265: ...or in the user documentation 4 6 2 Installation The B R Automation Device Interface ADI driver also includes the Control Center and user documentation can be downloaded at no cost from the Downloads s...

Page 266: ...nt Kit screenshots Features Header files and import libraries Help files Example projects ADI DLL for testing applications if no ADI driver is installed The appropriate ADI driver for the device must...

Page 267: ...ots Features ADI NET class library Help files help documentation is in English Sample projects and code snippets ADI DLL for testing applications if no ADI driver is installed The appropriate ADI driv...

Page 268: ...A B C etc Keyboard shortcuts CTRL C SHIFT DEL etc on one key Special key functions change brightness etc Assignment of LED functions HDD access power etc 4 assignments possible per key using layers C...

Page 269: ...rectly from a USB flash drive without installation on the target device for example An installed ADI driver is required for the full range of functions Figure 149 B R KCF Editor version 1 0 screenshot...

Page 270: ...he Windows PE operating system and HMI Service Center installed on it For details about the HMI Service Center see the HMI Service Center user s manual This can be downloaded at no cost from the B R w...

Page 271: ...f EU directive Electromagnetic compatibility 2014 30 EU and are designed for industrial applications EN 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN 61000 6 2 2005...

Page 272: ...Eq E115267 Products with this mark are tested by Underwriters Laboratories and listed as indus trial control equipment The mark is valid for the USA and Canada and facilitates the certification of you...

Page 273: ...ion of the original documentation 273 5 2 4 RCM Products with this mark are tested by an accredited test laboratory and certified by the ACMA The mark is valid for Australia Oceania and facilitates th...

Page 274: ...of the components must be observed when operating the complete system All components listed in this manual have undergone intensive system and compatibility testing and been approved accordingly B R c...

Page 275: ...55 C Humidity B up to 100 Vibration A 0 7 g EMC B bridge and open deck 2 Terminal block Note Protected against vibration by the screw flange Nominal data per UL Number of pins 3 female Type of termin...

Page 276: ...us HazLoc E180196 Industrial control equipment for hazardous locations Class I Division 2 Groups ABCD T41 DNV GL Temperature B 0 55 C Humidity B up to 100 Vibration A 0 7 g EMC B bridge and open deck...

Page 277: ...n the USB flash drive 6 4 1 2 Order data Model number Short description Figure USB accessories 5MMUSB 2048 01 USB 2 0 flash drive 2048 MB B R 5MMUSB 4096 01 USB 2 0 flash drive 4096 MB B R Table 273 5...

Page 278: ...A in sleep mode max 120 mA read write Environmental conditions Temperature Operation 0 to 70 C 2 0 to 70 C 2 Storage 50 to 100 C Transport 50 to 100 C Relative humidity Operation 85 non condensing Sto...

Page 279: ...Temperature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 150 5MMUSB xxxx 01 Temperature Humidity diagram Diagram l...

Page 280: ...his can be avoided by running fdisk mbr on the USB flash drive 6 4 2 2 Order data Model number Short description Figure USB accessories 5MMUSB 032G 02 USB 3 0 flash drive 32 GB MLC Table 275 5MMUSB 03...

Page 281: ...properties Dimensions Width 16 58 mm Length 48 30 mm Height 7 60 mm Weight 10 g Manufacturer information Manufacturer Innodisk Manufacturer s product ID DEUA1 32GI61BCH88 USB Drive 3ME Table 276 5MMU...

Page 282: ...PC2200 battery compartment 6 5 1 1 5ACCRPC2 0003 000 Technical data Model number 5ACCRPC2 0003 000 General information Battery Type Panasonic 1000 mAh Nominal voltage 3 V Service life 8 years 1 Remova...

Page 283: ...7 1 Cleaning Danger The device is only permitted to be cleaned when it is switched off in order to avoid triggering uninten tional functions by touching the touch screen or pressing keys Use a damp c...

Page 284: ...ges however Image persistence is also referred to in the technical literature as screen burn in image retention memory effect memory sticking or ghost image There are 2 different types Area type This...

Page 285: ...tion lever e g applying a large amount of force can lead to a defect in the ejector mechanism 1 Disconnect the power supply cable to the B R industrial PC disconnect the power cable 2 Remove the Torx...

Page 286: ...pply cable to the B R industrial PC disconnect the power cable 2 Carry out electrostatic discharge on the housing or at the ground connection 3 Pull out and remove the battery compartment Figure 154 C...

Page 287: ...or repair of the device may result in personal injury and or serious damage to property Therefore do not carry out any repairs yourself Repairs are only permitted to be carried out by authorized quali...

Page 288: ...peration buttons USB forwarding Daisy chain display operation touch screen USB forwarding Panel locking mechanism configurable via the B R Control Center ADI driver Backlight control of a connected B...

Page 289: ...be because the cable manufacturer has not provided a value for certain technical data NO Normally open Stands for a normally open relay contact TBD To be defined Used in technical data tables if there...

Page 290: ...red with the Autotex panel overlay starting with the following revision 5AP923 1215 00 revision B8 5AP923 1505 00 revision B8 5AP923 1906 00 revision B8 Panel overlay Touch screen Coated front frame F...

Page 291: ...evices User s manual V 1 05 Translation of the original documentation 291 AP9x3 and AP1000 multi touch panels are equipped with a continuous glass surface Touch screen Coated front frame Figure 158 Mu...

Page 292: ...hthalate Diesel Diethyl ether Diethyl phthalate Dioxan Dowandol DRM PM Iron chloride FeCl2 Iron chloride FeCl3 Acetic acid 50 Ethyl acetate Linseed oil Aviation fuel Formaldehyde 37 to 42 Glycerine Gl...

Page 293: ...ylbenzene Methyl ethyl ketone Methylisobutylketone Sodium bisulphate Sodium carbonate Sodium hydroxide 40 Sodium hypochlorite 20 Paraffin oil Phosphoric acid 30 Phthalate Nitric acid 10 Sea water Cutt...

Page 294: ...hexane Isopropanol Coffee Methylbenzene Methylene chloride Methyl ethyl ketone Mineral spirits Motor oil Nitric acid 70 Saline solution 5 Tea Turpentine Lubricants Sulphuric acid 40 Cooking oil 3M to...

Page 295: ...erature Operation Storage Transport 20 to 70 C 40 to 80 C 40 to 80 C Relative humidity Operation Storage Transport 90 at max 50 C 90 RH at max 60 C for 504 hours 90 RH at max 60 C for 504 hours Operat...

Page 296: ...s used for example Product ID 3M touch screen General information Certifications CE Yes Manufacturer 3M Technology Projected capacitive touch PCT Light transmission 88 2 Anti reflective coating Chemic...

Page 297: ...l components and may differ from those of the complete system The data specified for the complete system applies to the complete system in which this individual component is used for example Product I...

Page 298: ...ature Humidity diagram T C 0 100 100 0 80 5 10 20 30 40 50 60 70 80 90 95 60 70 50 40 30 20 10 90 80 70 60 50 40 30 20 10 RH 2 1 Figure 161 3M touch screen generation 3 Temperature Humidity diagram Di...

Page 299: ...000 131 5AP1120 1906 000 138 5AP1130 0702 000 97 5AP1130 101E 000 101 5AP1130 121E 000 120 5AP1130 156C 000 133 5AP1130 185C 000 136 5AP1151 0573 000 92 5AP1180 1043 000 106 5AP1180 1505 000 125 5AP11...

Page 300: ...built in devices User s manual V 1 05 Translation of the original documentation Publishing information B R Industrial Automation GmbH B R Strasse 1 5142 Eggelsberg Austria Telephone 43 7748 6586 0 Fax...

Reviews: