32 |
Calibration |
B&G Triton Display Installation Manual
1.
Bring the boat up to cruising speed (above 5 knots)
2.
Select Auto on the Boat speed calibration page
3.
When the calibration is completed the Boat speed calibration scale will
show the adjusted percentage value of the boat speed.
USE SOG as boat speed
If boat speed is not available from a paddle wheel sensor it is
possible to use speed over ground from a GPS. SOG will be
displayed as boat speed and used in the true wind calculations and
the speed log.
Manual adjustment of boat speed
Adjust the boat speed manually by selecting the Boat speed
percentage slider. Adjust the percentage up or down as desired.
Confirm the value. Select OK once complete.