1.5  

 Warnings and  safety precautions  

General

•  In accordance with its intended use and these user instructions, the  shaking device 

must only be used together with a SONOREX DIGITEC DT 1028 F ultrasonic bath. 
Consequently, the  safety information in the SONOREX DIGITEC F series user 
instructions also applies.

•  Keep the  shaking device out of the reach of children and also of persons who have 

not been instructed in their  operation by reference to these instructions.

•  Do not insert any objects in the  coupling opening.
• The  

shaking device adheres to prescribed EMC limit values, such that it can be 

assumed that the electromagnetic radiation emanating from the unit is harmless to 
humans. However, a binding statement for wearers of implants can only be made 
at the place of work and together with the implant manufacturer. In case of doubt, 
information regarding the allowable electromagnetic exposure level is to be obtained 
from the implant manufacturer.

•  Keep the surface of the device and the  controls clean and dry! 
• For  

cleaning and  disinfection, only use  cleaning agents and surface disinfectants 

which are suitable, approved, tested and compatible with the materials. 

•  The user instructions with their  safety instructions must remain with the unit and 

must be observed without fail!

•  If the  shaking device is passed on, the user instructions with the  safety instructions 

must also be handed over.

 Damage and  defects

•  If any damage is identi

fi

 ed, do not connect the  shaking device up to the power 

supply.

• In  

the event of defects, disconnect the  mains plug immediately.

•  

Repairs are only to be conducted by  authorised skilled personnel or by the 
 manufacturer!

•  

Defective parts may only be replaced with original parts.

Operation and  transport

•  Only plug the  shaking device in to an outlet with a grounded socket.
•  

Observe ambient conditions, see Section 1.4. 

•  

Only insert and  remove samples with the  shaking device switched o

 .

• Secure 

fl

 asks in the  roller carriage prior to switching on the shaking in order to 

ensure that they do not move and/or topple over.

•  To avoid  damage and environmental risks as well as damaging the samples, 

suitable, sealed 

fl

 asks should be used. 

•  To avoid  wave pounding, maintain the 

fi

 lling level in the  ultrasonic bath and adjust 

the  power setting to the number of samples.

•  Do not touch any parts of the device or reach into the device when shaking is in 

progress. 

Summary of Contents for SONOSHAKE

Page 1: ...User Instructions SONOSHAKE Shaking device SA 1028 Accessories for SONOREX DIGITEC DT 1028 F ultrasonic baths 51336 005en 2022 03...

Page 2: ...en the translation and the original of this document the original version has priority BANDELIN accepts no responsibility or liability for damages caused by improper handling or usage contrary to the...

Page 3: ...t of unauthorised alterations modifications both the warranty claim and the CE conformity will expire If any service is required please contact the specialist dealer in charge or the manufacturer Symb...

Page 4: ...ectromagnetic ambient conditions EMC 9 1 5 Warnings and safety precautions 10 2 Preparation 11 2 1 Scope of delivery 11 2 2 Set up assembly 12 2 2 1 Fastening material set 12 2 2 2 Installing the moun...

Page 5: ...e for the application 18 4 2 Shaking 19 5 Cleaning disinfection and care of the device 21 5 1 Warehousing storing 21 6 Maintenance and repair 22 6 1 Repairs and service 22 6 2 Decontamination certific...

Page 6: ...continuous operation 3 Knob power selection switch for 0 25 50 75 or 100 4 Drive unit with compact easy to clean stainless steel housing 5 1 1 Mode of operation The shaking device comprises a roller...

Page 7: ...f fluids with a high gas content For the intended use the samples must be placed in suitable vessels e g laboratory flasks and secured in the roller carriage indirect operation Existing SONOREX DIGITE...

Page 8: ...z mains cable length 2 m Max current consumption 0 8 A 230 V 1 3 A 115 V Protection class I Emission sound pressure level A weighted 70 dB A Drive unit Exterior dimensions 225 320 235 mm Weight 4 kg i...

Page 9: ...tic ambient conditions EMC The device was tested to DIN EN 61326 1 for electromagnetic compatibility EMC and complies with the requirements for class B devices according to EN 55011 It is suitable for...

Page 10: ...nd disinfection only use cleaning agents and surface disinfectants which are suitable approved tested and compatible with the materials The user instructions with their safety instructions must remain...

Page 11: ...arriage separately Do not allow the unit to run without supervision 2 Preparation Carefully unpack the shaking device and accessories and inspect them for completeness or possible transportation damag...

Page 12: ...bH Co KG Heinrichstra e 3 4 12207 Berlin Deutschland info bandelin com 2 2 Set up assembly Danger Guard against moisture and wetness risk of electric shock Installation of the shaking device SA 1028 i...

Page 13: ...right handle of the ultrasonic bath Place the terminal strip on the handle Secure the mount and the terminal strip on the handle with the washers and screws Important The mount must be secured central...

Page 14: ...ly on the rim of the bath If the roller carriage wobbles or grinds on the rim of the bath it should be adjusted using the screw rear left outside After adjustment check whether the clamp bearing is on...

Page 15: ...with the mains 2 4 Start up Release the coupling on the roller carriage Grasp the lever 1 behind the bearing cup 2 and pull it upwards Leave or place the clip bearing 3 back on the ball stud The rolle...

Page 16: ...utes Once the time has elapsed the time switch will automatically turn o By turning the knob back the operating time will be shortened i e the time switch will be turned o Continuous operation Turn kn...

Page 17: ...3 2 Power setting The shaking frequency will be adjust via the knob for power setting shakes min Possible power settings shaking frequency shakes min 0 25 50 75 100 0 55 110 165 220 The shaking freque...

Page 18: ...fluid in the inset beaker without loss if possible For more detailed information and instructions on correct ultrasound applications please refer to the user instructions for the ultrasonic bath 4 1...

Page 19: ...laced The laboratory flasks can be secured in the roller carriage with EK holding clamps see chapter 7 1 Equip the roller carriage with laboratory flasks The laboratory flasks must be immersed at leas...

Page 20: ...flasks from the roller carriage CAUTION Depending on the length of the sonication the flasks samples may be hot Before the next sonication verify the service life of the contact liquid Heed the speci...

Page 21: ...aneous rust produces localised corrosion of the roller carriage For this reason remove rust stains immediately using a soft cloth and a commercial stainless steel cleaning product without abrasive add...

Page 22: ...88 02 00 13 In the case of returns the general terms and conditions for delivery and payment of BANDELIN electronic GmbH Co KG shall apply In addition the device is to be cleaned and decontaminated i...

Page 23: ...s or from our website No obligation telephone consultation Internet 49 0 30 768 80 0 www bandelin com 7 1 Required accessories EK holding clamps are required for securing the laboratory flasks They pr...

Page 24: ...ste Electrical and Electronic Equipment Directive 2012 19 EU Any supplementary deviating regulations must be observed The device must be decontaminated before disposal It can then be disposed of as el...

Page 25: ...Note The user instructions in this and other languages as well as further information are available on the supplied CD...

Reviews: