background image

 

1

2

3

1 = HF "+"
2 = HF "-"
3 = PE

Label:

1500 W

25 kHz

12 / 25

23526b GB/2019-07

1

 electronic GmbH & Co. KG  •  Heinrichstraße 3-4  •  12207 Berlin  •  Deutschland  •  [email protected]

•  Hang the generator in a dust-free, dry position. 

A minimum distance of 10 cm in all directions is required for suf

fi

 cient cooling 

  Installation in an enclosed construction is not permitted.

•  Drill holes for the screws (e.g. M5) leaving 255 mm between them and paying 

attention to suf

fi

 cient height.

•  Attach the bracket on the left or right using the screws in the housing as shown 

in the 

fi

 gure.

•  Mount the generator.

2.2.2  HF connection for ultrasonic transducer  

One or more ultrasonic transducers with a maximum total output of 1,500 W can be 
connected to a generator (cleaning baths, immersible transducers, 

fl

 at transducer 

plates, reactors, etc.) The minimum connected output of 300 W per HF unit must be 
upheld.

Correct connection of the HF unit(s) with the load:

The factory-set data for the HF unit is af

fi

 xed next 

to the HF connection socket.

HF output socket:

  Connect the installed ultrasonic transducers (cleaning tanks (TM), immersible 

transducers, 

fl

 at transducer plates, reactors, etc.) to the respective HF units 

on the rear of the generator using the HF cable (maximum length of 
HF feed cable: 20 m). 
The correct assignment of the load to the HF unit (frequency and maximum output) 
must be taken into account under all circumstances!

The 3-pole plug should be connected to the generator as follows:
-  Align and insert the plug (without rubber bushing) and socket (red dot at top, on 

both sides) into one another until the connection clicks into place! 
If the plug is not correctly plugged in and locked in place, this can lead to failure 
of the connection (scorching) or the generator.

-  In order to join multiple ultrasonic transducers for connection to an HF unit, 

the appropriate TV 2 or TV 4 junction boxes with HF feed cables must be 
available or ordered.

HF cables with plug connectors should be protected against splash water or moisture 
(protection class: IP 51).

Summary of Contents for SONOREX TECHNIK TG Series

Page 1: ...3 4 High performance ultrasonic generator series TG for the operation of ultrasonic cleaning tanks TM ultrasonic immersible transducers flat transducer plates or reactors valid for Compact housing TG...

Page 2: ...the translation and the original of this document the original version will take precedence BANDELIN accepts no responsibility or liability for damage caused by improper handling or usage contrary to...

Page 3: ...dling or usage contrary to the intended purpose In the event of unauthorised alterations modifications both the warranty claim and the CE conformity will become void If service is required please cont...

Page 4: ...11 2 1 Scope of delivery 11 2 2 Installation connection 11 2 2 1 Optional mounting bracket TGW 1 11 2 2 2 HF connection for ultrasonic transducer 12 2 2 3 Remote control connection 13 2 2 4 RS 232 in...

Page 5: ...adjustment TRANSDUCER 20 6 2 4 Short circuit and open circuit TRANSDUCER 21 6 2 5 Dry running identification DRY 21 6 3 Customer service 22 6 3 1 Repairs and service 22 6 3 2 Decontamination certific...

Page 6: ...ble transducers of the same or also different frequencies can be connected to a TG 3003 generator The HF units are programmed to the intended operating frequency by the manufacturer see label s on the...

Page 7: ...om the mains mains frequency 50 or 60 Hz into high frequency energy with a frequency of 25 or 40 kHz Thanks to the ultrasonic transducers that are connected to the ultrasound generator the high freque...

Page 8: ...f conformity can be requested from the manufacturer by providing the serial number 1 4 Technical data The ultrasonic generator is interference free and marked with a CE Safety EN 61010 1 EMC EN 61326...

Page 9: ...EN 61 010 1 Overvoltage category II Degree of contamination 1 Permissible ambient temperature 5 to 45 C Permissible relative humidity up to 31 C 80 Permissible relative humidity up to 40 C 50 Condens...

Page 10: ...forbidden to connect any type of power or voltage sources to the generator s signal inputs or outputs If the unit is passed on to others the user instructions and the safety instructions must also be...

Page 11: ...ormance ultrasonic generator see delivery slip 1 user instructions Additional accessories according to order see delivery slip 2 2 Installation connection Place the generator on a firm level and dry s...

Page 12: ...the load The factory set data for the HF unit is affixed next to the HF connection socket HF output socket Connect the installed ultrasonic transducers cleaning tanks TM immersible transducers flat tr...

Page 13: ...elin com Note Multiple ultrasonic transducers of the same frequency can be connected to one HF unit up to the specified output on the type plate until the sum of the individual outputs is equal to the...

Page 14: ...rror TEMPERATURE red Flashes if the power is reduced due to excessively high temperatures inside the generator TRANSDUCER red Lights up permanently in the case of a short circuit Defective transducer...

Page 15: ...he oscillating tank for a longer period of time must be degassed prior to use Remove basket and other accessories from the oscillating tank Place lid on top For degassing start the ultrasound for abou...

Page 16: ...ess the mains switch The fan on the rear of the generator turns on When the power is switched on all LEDs light up for approx 4 seconds at the HF unit The TEMPERATURE LED flashes during this time Turn...

Page 17: ...er No guarantee is provided for damage caused by the use of unsuitable disinfection agents or detergents 5 1 Cleaning and care Fans cooling of the generator The generator must be cleaned regularly Eve...

Page 18: ...enerator functions are controlled by the program At the beginning of troubleshooting the mains switch should be turned off After approx 6 seconds it should be turned on again In the process the LEDs o...

Page 19: ...r load with Test sheets for ultrasonic high performance transducer system or contact the manufacturer Flashes Lights up Flashes or dark Flashes or flickers Flashes or dark Lights up Flashes or dark Li...

Page 20: ...th the cooling element temperature creates a working state in which the HF unit continues to work safely with a reduced output allowing work to continue Once the excessive temperature has been resolve...

Page 21: ...of the dropping of the liquid level in the cleaning tank If the liquid level above the surface of a connected ultrasonic transducer drops below 5 mm the ultrasonic output is considerably reduced in o...

Page 22: ...rlin Repair service E mail Phone 49 0 30 768 80 13 info bandelin com Fax 49 0 30 76 88 02 00 13 In the event of returns the General Terms and Conditions for Delivery and Payment of BANDELIN electronic...

Page 23: ...ntrol with timer BANDELIN order No 8466 or the FS 7 remote control cable BANDELIN order No 8468 Simple on off function via relay switch SPS etc This can be done by inserting the 5 pole plug of the res...

Page 24: ...y utilise the ultrasound Additional information may be obtained from our supplier our sales representatives or from our website No obligation telephone consultation Website 49 0 30 768 80 280 www dr s...

Page 25: ...Note The instructions for use in this and other languages as well as further information can be found on the enclosed CD...

Reviews: