Ensure that the machine is installed on a level floor of sufficient strength and
that the recommended clearances for inspection and maintenance are provided.
Never allow the inspection and maintenance space to be blocked.
4.4
Machine Foundation
A proper foundation is an absolute necessity when installing a fixed mount washer extractor. Do
not neglect details when doing foundation work. These details will ensure a stable installation,
reducing the possibility of excess vibration at high speeds.
The machine must be anchored to a smooth level surface so that the entire base of the machine is
supported and rests on the mounting surface.
Note! Do not support the machine at only four points.
A concrete base designed to elevate the washer-extractor to a more comfortable working height
may be used. Use care when designing a base, as the forces generated during extract are extreme.
The base must be adequately tied into existing floor.
The factory can provide, at extra cost, elevated base frames designed to handle the extreme forces
encountered during the extract phase of the cycle. Using other non-factory designs can cause
undesirable operation, machine damage, and in extreme circumstances, injury or death. Damage
caused by use of non-factory base frames is not covered under warranty.
Do not attempt to install this machine on wooden flooring of any kind, above ground level, or over
basements. Installation must be slab on grade or equal.
Figure 4.2: Floor Load Data
17
Summary of Contents for HE-110
Page 1: ...Washer Extractor HE Series Installation and Operation Manual November 4 2014 Revision 2 91 ...
Page 5: ...Figure 1 HE Product Family 1 ...
Page 8: ...Figure 1 2 Key Symbols Figure 1 3 Key Symbols 4 ...
Page 13: ...Chapter 3 General Specifications Figure 3 1 HE Series General Specifications 9 ...
Page 14: ...Figure 3 2 HE Series Basic Dimensions 10 ...
Page 37: ...Figure 4 20 Inverter Drive to Motor Detail 33 ...