4.5.2
HE-45 Mounting Bolt Installation
The HE-45 uses 1/2-13 x 8”’ bolts. Embed the bolts in 3500 psi reinforced concrete with a minimum
of 6”’ thickness. The threaded end of the bolt should extend 2 inches from the surface of the
floor. Use the outboard bolt holes for standard installation, the inboard bolt holes for side by side
installations, or installations near a wall or other object that would prevent access to the outboard
holes. Refer to figure 4.7 on page 21.
Figure 4.7: HE-45 Mounting Detail
21
Summary of Contents for HE-110
Page 1: ...Washer Extractor HE Series Installation and Operation Manual November 4 2014 Revision 2 91 ...
Page 5: ...Figure 1 HE Product Family 1 ...
Page 8: ...Figure 1 2 Key Symbols Figure 1 3 Key Symbols 4 ...
Page 13: ...Chapter 3 General Specifications Figure 3 1 HE Series General Specifications 9 ...
Page 14: ...Figure 3 2 HE Series Basic Dimensions 10 ...
Page 37: ...Figure 4 20 Inverter Drive to Motor Detail 33 ...