4.5.5
HE-110 Mounting Bolt Installation
The HE-110 uses 5/8-11 x 8”’ bolts. Embed the bolts in 3500 psi reinforced concrete with a mini-
mum of 9”’ thickness. The threaded end of the bolt should extend 2 inches from the surface of the
floor. Use the outboard bolt holes for standard installation, the inboard bolt holes for side by side
installations, or installations near a wall or other object that would prevent access to the outboard
holes. Refer to figure 4.10 on page 24.
Figure 4.10: HE-110 Mounting Detail
24