Important Safety Information
SAFETY CHECK LIST
Before Initial start up of a B&C washer –
extractor perform the following safety check:
A.
Make sure all electrical and plumbing
connections have been made in
accordance with applicable codes and
regulations.
B.
Make sure the machine is
grounded electrically.
C.
Make sure the machine has
flexible water fill and drain
connections of the correct size,
length and type, with no kinks,
and that they are securely
attached and/or clamped.
D.
Make sure any transport brackets have
been removed.
Before servicing any equipment, make certain it
is disconnected from the electrical power
source. Never allow operation of the machine
when any safety device is malfunctioning.
Never bypass safety devices.
6
Before machine is placed in operation, the door
safety interlock must be checked for proper
operation as follows:
A.
When the washer is energized
electrically and in operation, the
loading door must be locked in
the closed position. Verify this by
attempting to open the loading
door when the machine is
operating. If necessary, check the
door safety interlock and sensors
for proper operation. Consult
the service manual, or call a
qualified service technician if
necessary.
B.
When the washers loading door
is open, it should not be possible
to start the machine. Verify this
by attempting to start the washer
with the door open. Also, close
the door without locking it
and verify that it is not possible to
start the machine with the door
not locked. If necessary, check
the door lock sensors for proper
operation,. Consult the service
manual, or call a qualified
service technician. If additional
information is required, contact
your local distributor or call the
manufacturer of the machine.