Technical Data: 

 

Measuring signal 

4 ... 20 mA, for connection to the BAMOPHOX TUR measuring amplifier 

 

Observe: 

If a different measuring amplifier is used, an external 10 to 30 V DC voltage source is required. 

  The measuring signal output is a current sink (see wiring diagram at the end of these instructions). 

 
Auxiliary supply power 

24V DC

rated

  (10 ... 30V DC) 

 
Connected load 

0.5 W 

 

Remark: if the measuring circuit is also connected to the auxiliary power supply of 
the load will increase to additional 24 VDC x 20mA = 0,48W 

 

Terminal housing:  

PBT, IP 65 

 
Ambient temperature 

+5 ... +45° C 

 

Medium temperature 

PVC-type: 

+5 ... +  60° C 

  

PP-Type: 

+5 ... +  80° C 

 

Max. allowable operating pressure 

6 bar max. 20°C / 1 bar max. 60°C 

 

Measuring range 

Version 20:  

0,01 … 20 FNU 

Version 1000: 

0,1 … 1000 FNU  

(5 selectable resolutions) 
FNU - “Formazine Nephelometric Units“ 

 

Measuring accuracy 

±5 % of actual measuring value, 
±1 % of upper limit of effective range 

 

Colour- / Fouling compensation: 

only for TURBICUBe 20 available 

 

Control elements 

6-fold DIP switch , calibration potentiometer 

 

Indicators 

Status LED (green) 

 
 

CE Mark: 

 

In accordance with low-voltage directive RL 2006/95/EC and EMC directive 2004/108/EC 
 
 

 

Summary of Contents for IER Turbicube 1000

Page 1: ...Functions Description The turbidity measuring device determines the turbidity of liquids using the light absorption and scattered light measuring method The inline measuring cell at the sensor set mak...

Page 2: ...mark if the measuring circuit is also connected to the auxiliary power supply of the load will increase to additional 24 VDC x 20mA 0 48W Terminal housing PBT IP 65 Ambient temperature 5 45 C Medium t...

Page 3: ...OFF OFF OFF OFF OFF DIP switch 5 and 6 without function Normal position OFF armatures with nominal diameter DN65 DN100 Troubleshooting Measuring current 22 mA overflow Measuring current 0 mA wrong DI...

Page 4: ...Module PCB Elektrical Connection Observe The measuring output 4 20 mA is a current drain that means the output channel has the same electrical behavior as a variable resistor A active power supply fo...

Page 5: ...e fixture by unscrewing the sleeve nuts screw the ETR glasses with the included tool and remove clean the lens do not use abrasive cleansers which may cause scratching tighten the ETR glasses with the...

Page 6: ...ng is required as part of the respective quality assurance system for test equipment monitoring calibration can be checked with the calibration rods and the device can be readjusted if necessary A sui...

Page 7: ...bration rod from the box Insert the calibration rod into the fixture Mount the S2 transmitter to the calibration rod observe the locking pin Insert the calibration rod with attached transmitter comple...

Page 8: ...SW1 setpoint on the plate in the box of the KN D calibration rod Actual value measured value Setpoint actual value deviation Less than 5 measuring instrument is OK Greater than 5 adjust actual value...

Page 9: ...onnection both side flange DIN 2501 DN20 d25 240 240 300 300 DN25 d32 240 240 300 300 DN32 d40 240 240 300 300 DN40 d50 240 240 300 300 DN50 d63 262 262 342 300 DN65 d75 314 314 342 300 DN80 d90 347 3...

Reviews: